KERN KXS-TM Manuale utente

KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating and Installation
Instructions Display Unit
KERN KXS/KXG-TM
Version 2.2
2017-12
GB
KXS/KXG-TM-BA_IA-e-1722

2 KXS/KXG-TM-BA_IA-e-1722
GB
KERN KXS/KXG-TM
Version 2.2 2017-12
Operating and installation instructions
Display unit
Contents
1Technical data ................................................................................................... 5
2Appliance overview........................................................................................... 6
2.1 Keyboard overview .................................................................................................... 7
2.1.1 Models KXS-TM: ................................................................................................................ 7
2.1.2 Models KXG-TM: ............................................................................................................... 8
2.2 Overview of display ...................................................................................................10
3Basic Information (General) ........................................................................... 12
3.1 Proper use ................................................................................................................12
3.2 Improper Use ............................................................................................................12
3.3 Warranty ...................................................................................................................12
3.4 Monitoring of Test Resources ...................................................................................13
4Basic Safety Precautions................................................................................ 13
4.1 Pay attention to the instructions in the Operation Manual .........................................13
4.2 Personnel training .....................................................................................................13
5Transport and storage .................................................................................... 13
5.1 Testing upon acceptance ..........................................................................................13
5.2 Packaging / return transport ......................................................................................13
6Unpacking and placing................................................................................... 14
6.1 Installation Site, Location of Use ...............................................................................14
6.2 Unpacking and placing ..............................................................................................14
6.3 Scope of delivery / serial accessories: ......................................................................14
6.4 Transport Securing ...................................................................................................15
6.5 Placing ......................................................................................................................15
6.6 Mains connection ......................................................................................................15
6.7 Rechargeable battery operation (Factory option) ......................................................15
6.8 Adjustment ................................................................................................................16
6.9 Verification ................................................................................................................16
7Basic Operation............................................................................................... 18
7.1 Start-up .....................................................................................................................18
7.2 Switching Off ............................................................................................................18
7.3 Zeroing .....................................................................................................................18
7.4 Simple weighing ........................................................................................................18
7.5 Switch-over weighing unit .........................................................................................19
7.6 Weighing with tare ....................................................................................................19
7.6.1 Taring ............................................................................................................................... 19
7.6.2 Delete tare ....................................................................................................................... 19
7.6.3 Numerical input of tare (PRE-TARE) ............................................................................... 20
7.7 Gross/Net call-up ......................................................................................................20

KXS/KXG-TM-BA_IA-e-1722 3
8Applications:.................................................................................................... 21
8.1 Parts counting ...........................................................................................................21
8.2 Totalization ...............................................................................................................23
9Menu................................................................................................................. 27
10 Indicator settings (menu block "01 FnC") ................................................. 28
10.1 Backlighting of the display (function "FnC 01") ..........................................................31
10.2 Automatic power cut "Auto power off (function „FnC 02“) ..........................................32
10.3 Weighing with tolerance range (function "FnC 03 „) ..................................................33
10.4 Resetting to factory settings (function "FnC 04 „) ......................................................37
10.5 Automatic zero-adjusting/ stability and response settings (function "FnC 05“) ..........38
10.6 Data Hold functions (function "FnC 06“) ....................................................................40
10.6.1 Animal weighing function ............................................................................................. 41
10.7 Automatic reference optimisation with the unit count (function „FnC 07“) ..................46
10.8 Automatic storage of zero point (function "FnC 10“) ..................................................47
10.9 Function of the F-key (function „FnC 12“) ..................................................................48
10.10 Auto Zero ..............................................................................................................49
11 External adjustment "Unverified weighing systems „ (menu block "02
EC”) 50
12 Settings RS 232 (menu block "03 rS1”)..................................................... 53
12.1 Baud rate (function "rS1 01“) ....................................................................................56
12.2 Parity (function "rS1 02“) ...........................................................................................57
12.3 Output format (function "rS1 03“) ..............................................................................58
12.4 Output format (function „rS1 04“) ..............................................................................60
12.5 Continuous output rate (function „rS1 05“) ................................................................61
12.6 Automatic data output with zero display (function "rS1 06“) ......................................62
12.7Condition for data output (function "rS1 08”) .............................................................63
12.8 6/ 7-digit data format (function "rS1 09”) ...................................................................64
12.9 Set the date/ time (function "rS1 10“) ........................................................................65
13 Instruction mode.......................................................................................... 68
14 Data output format....................................................................................... 70
14.1 7-digit data format (first decimal place not included) .................................................70
14.2 6-digit data format (first decimal place not included) .................................................70
15 Bluetooth (Factory option).......................................................................... 71
16 Servicing, maintenance, disposal .............................................................. 75
16.1 Clean ........................................................................................................................75
16.2 Servicing, maintenance .............................................................................................75
16.3 Disposal ....................................................................................................................75
16.4 Error messages ........................................................................................................75
17 Instant help................................................................................................... 76
18 Installation display appliance/ load cell..................................................... 77
18.1 Weighing system design ...........................................................................................77
18.2 Attach the load cell ...................................................................................................78
18.3 Attach RS232 ...........................................................................................................79

4 KXS/KXG-TM-BA_IA-e-1722
19 Service menu ............................................................................................... 80
19.1 Configure weighing system / menu block ..............................................82
19.1.1 Unverified weighing systems (function „CSP 01”) ....................................................... 83
19.1.2 Verified balancing systems (function "CSP 02“) .......................................................... 87
19.1.3 Set the buffeting point (function „CSP 03“) ................................................................. 91
19.2 Linearization/ menu block .....................................................................93
19.3 Adjustment of "verified weighing systems / menu block " ...................97
19.4 Amend the local gravitation zone/ menu block .................................... 100
19.5 Appliance settings/ menu block ..................................................... 101
19.5.1 Parameter „adjustment to site conditions“ (function „CFn 01”) ................................. 102
19.5.2 Configuration „verified/ unverified“ (function „CFn 02“) ............................................. 105
19.5.3 Resetting to zero when switched on (function "CFn 04“) .......................................... 106
19.5.4 Amend the DATA Hold function of verified weighing system (function „CFn 05“) .... 107
19.5.5 Auto zero (verified weighing systems)/ function "CFn 06“ ........................................ 109
19.5.6 Parts counting on / off „CFn 07“ ................................................................................ 110
20 Declaration of Conformity......................................................................... 111

KXS/KXG-TM-BA_IA-e-1722 5
1 Technical data
KERN KXS-TM KXG-TM
Display 6-digit
Solution verifiable Single (Max.) 10,000 e
Dual (Max.) 5,000 e
Resolution non-verifiable 30,000 d
Verification class III
Weighing ranges Max. 2
Weighing Units g, kg
Divisions 1,2,5,…10, n
Display LCD 55 mm digits with back lighting
DMS weighing cells Max. 8 x 350 Ω
Electric Supply Input voltage 110-230 V AC
Built-in power supply unit
Rechargeable battery
optional
Factory option
6 V, 4.5 Ah
Operating time (backlight on) 40 h
Operating time (backlight off) 80 h
Loading time 12 h
Admissible
ambient temperature -10°C – 40°C
Humidity of air < 85 % relative (not condensing)
Net weight 2500 g 2000 g
Dimensions Width x Depth
x Height,
(mm)
232 x 170 x 80
Interfaces
Factory option
RS232:
KXS-A04
RS485:
KXS-A01
Bluetooth:
KXS-A02
Protection type IP 68 according to DIN 60529

6 KXS/KXG-TM-BA_IA-e-1722
2 Appliance overview
1
Wireless
2
Status of rechargeable battery
3
Wall bracket
4
Locking screw
5
Display
6
Keyboard
7
Electric Supply
8
RS 232 / RS485 (Factory option)
9
Connection to the load cell

KXS/KXG-TM-BA_IA-e-1722 7
2.1 Keyboard overview
2.1.1 Models KXS-TM:
Button Description Function
ON/OFF button 1. Turn on/off
F-key • Functional button (allocation see chap. 10.1
FNC-03)
BG/ NET key • Gross weight switch over to net weight
UNIT-key • Weighing unit
TARE button • Taring
• Confirm entry
ZERO key • Zeroing
M+/ PRINT key • Functional button (allocation see chap. 10.1
FNC-02)

8 KXS/KXG-TM-BA_IA-e-1722
2.1.1.1 Navigation keys and their function in the menu
• Increase flashing digit
• Scroll forward in menu
• Decrease flashing digit
• Scroll backwards in menu
• Digit selection to the right
• Take over selected setting
Digit selection to the left
2.1.2 Models KXG-TM:
Button Description Function
ON/OFF button • Turn on/off
F-key • Functional button (allocation see chap. 10.1
FNC-03)

KXS/KXG-TM-BA_IA-e-1722 9
BG/ NET key • Gross weight switch over to net weight
UNIT-key • Weighing unit
TARE button • Taring
• Confirm entry
ZERO key • Zeroing
M+/ PRINT key • Functional button (allocation see chap. 10.1
FNC-02)
2.1.2.1 Navigation keys and their function in the menu
• Increase flashing digit
• Scroll forward in menu
• Decrease flashing digit
• Scroll backwards in menu
• Digit selection to the right
• Take over selected setting
Digit selection to the left

10 KXS/KXG-TM-BA_IA-e-1722
2.2 Overview of display
HI / OK / LO Indicators for weighing with tolerance range
Kg Current selected unit of weight „kilograms“
Lb Current selected unit of weight „pound“
Pcs Indicator for counting
Zero indicator
Net The displayed weighing value is a net weighing value
Status of rechargeable battery
Altri manuali per KXS-TM
3
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali KERN Monitor

KERN
KERN KMF-TM Manuale utente

KERN
KERN KXE-TM Manuale utente

KERN
KERN KFS-TM Manuale utente

KERN
KERN YKD Series Manuale utente

KERN
KERN KFB-TM Manuale utente

KERN
KERN KMA-TM Manuale utente

KERN
KERN KIB-TM Manuale utente

KERN
KERN KXS-TM Manuale utente

KERN
KERN KXS-TM Manuale utente

KERN
KERN PFB-A08 Manuale utente