Kvaser U100S-X3 Manuale utente

Kvaser U100S-X3 User’s Guide
Copyright 2020-2022 Kvaser AB, Mölndal, Sweden
https://www.kvaser.com
Printed Sunday 29th May, 2022
We believe that the information contained herein was accurate in all respects at the time of printing.
Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note
that the information in this document is subject to change without notice and should not be construed
as a commitment by Kvaser AB.

Kvaser U100S-X3 User’s Guide 3 (24)
Contents
1 About this manual 4
2 Introduction 5
2.1 Welcome to Kvaser U100S-X3 . . . . . . . . . . . . . . . . . . . . . 5
2.2 Major features of Kvaser U100S-X3 . . . . . . . . . . . . . . . . . . 6
3 Kvaser U100S-X3 hardware 7
3.1 Hardware installation . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 USB connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 Kvaser MagiSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.4 CAN connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 CAN bus termination . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.6 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.7 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.8 Interface mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.9 The t programming language . . . . . . . . . . . . . . . . . . . . . . 13
3.10 Restrictions in t functionality . . . . . . . . . . . . . . . . . . . . . . 14
3.11 Updating the firmware . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 Troubleshooting 18
5 Safety Instructions 19
5.1 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2 Usage Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6 Disposal and Recycling Information 20
7 Legal Acknowledgements 21
7.1 EU Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . . 21
7.2 FCC Regulatory Compliance . . . . . . . . . . . . . . . . . . . . . . 22
7.3 Patents, Copyrights and Trademarks . . . . . . . . . . . . . . . . . . 23
8 Document Revision History 24
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 5 (24)
2 Introduction
This section will describe the functions and features of the Kvaser U100S-X3.
2.1 Welcome to Kvaser U100S-X3
Figure 1: Kvaser U100S-X3
Kvaser U100S-X3 is a small, yet powerful, CAN to USB interface. It provides
real-time transmission and reception of standard and extended CAN messages on
the bus with a high timestamp precision, and is compatible with applications that
use Kvaser’s CANlib.
This guide applies to Kvaser U100S-X3 devices using at least firmware and driver
versions listed in Table 1. For minimum compatible firmware and driver versions of
Kvaser U100S-X3 see Table 7 on Page 16.
Device Product Number Firmware Driver (Windows/Linux)
Kvaser U100S-X3 73-30130-01274-5 v3.25 v5.36 (kcany/mhydra)
Table 1: Firmware and driver versions needed to support all functionality present in
this guide.
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 6 (24)
2.2 Major features of Kvaser U100S-X3
•USB CAN interface with Kvaser tprogrammability.
•Powered through the USB connector.
•Supports CAN FD, up to 8 Mbit/s (with correct physical layer implementation).
•Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
•Supports silent mode for analysis tools – listen to the bus without interfering.
•Lightweight robust housing made of glass fibre reinforced polyamide
overmolded with TPE.
•Intuitive LED UI.
•Reinforced galvanic isolation, design validated with 5000 VAC rms applied for
60 s.
•Industrial grade temperature range, −40 ◦C to +85 ◦C.
•20 000 msg/s, each timestamped with a resolution of 1 µs.
•Kvaser MagiSync – automatic time synchronization (see Section 3.3, Kvaser
MagiSync, on Page 8 for more details).
•Fully compatible with applications written for other Kvaser CAN hardware
with Kvaser CANlib.
•Support for SocketCAN.
•Fully compatible with J1939, CANopen, NMEA 2000 R
and DeviceNet.
•IP67 rated housing.
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 7 (24)
3 Kvaser U100S-X3 hardware
In this section you can read more about the CAN channels, power supply and LED
indicators.
3.1 Hardware installation
The Kvaser U100S-X3 may be inserted in any free USB socket on the host
computer. You do not need to switch the power off before inserting or removing the
device. For the Kvaser U100S-X3 to communicate with the host computer, a
compatible version of the Kvaser driver and firmware must be installed.
The driver is installed by running the file
kvaser_drivers_setup.exe
. For
instructions on how to update the firmware, see Section 3.11, Updating the
firmware, on Page 16. The latest version of the driver and firmware can be
downloaded from www.kvaser.com/download.
The firmware is downloaded and installed directly on the Kvaser U100S-X3 and the
driver is installed on the host computer. After the driver has been installed on the
host computer, the firmware may then be downloaded and installed on the Kvaser
U100S-X3.
3.2 USB connection
The USB connector for the Kvaser U100S-X3 is a standard USB type “A”
connector (see Figure 2).
Figure 2: A standard USB type “A” connector.
Connect the device to your computer using any high quality USB 2.0 certified
cable. The maximum total USB cable length is 5 m (∼16 ft).
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 8 (24)
As USB cables become longer they are more sensitive to EMI,
because they make a longer antenna that can pick up more
noise. These issues can be mitigated by using higher quality
cables with better shielding. Thicker cables tend to be better than
thin ones, and braided shielding tends to be more reliable than
only foil. Furthermore, longer cables may introduce signal
degradation and timing issues that, if necessary, can be mitigated
using shorter cable segments combined with hubs that amplify
the signal and handle delays on a per-cable basis.
3.3 Kvaser MagiSync
Time synchronization is needed to achieve accurate and precise time stamping
between several host computer-to-bus interfaces connected to one host computer.
Since each host computer-to-bus interface uses its on-board clock to set the time
stamps.
Kvaser MagiSync is an innovative way to synchronize several different Kvaser USB
interfaces. You do not need external cables - you get instant synchronisation when
you connect the MagiSync enabled Kvaser USB device.
Figure 3: An example setup where all devices are synchronized via MagiSync.
For this to work the Kvaser USB interfaces must reside on the same USB root hub.
If they do not they will not be synchronized, see Figure 3 and Figure 4 on Page 9.
Usually, a computer has a USB controller with one root hub in a computer. If you
use that one, you do not need an external USB hub to get your Kvaser Devices
synchronized. The easiest way to verify the setup is to view Synchronized
Hardware in the Device Tree of “Kvaser Device Guide” in your computer’s control
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 9 (24)
Figure 4: Not all devices are synchronized via MagiSync in this setup.
panel. If all your hardware is placed in one Kvaser MagiSync Group, then you are
ready to go.
When connected correctly, all units are synchronized achieving a high precision
virtual clock accurate to the microsecond.
3.4 CAN connection
The Kvaser U100S-X3 has one CAN channel.
The CAN connector for the Kvaser U100S-X3 is the 16-pin OBDII Type B plug
which has the pinning described in Table 2.
Figure 5: OBDII Type B CAN connector.
OBDII pin number Function
4 GND
6 CAN_H
14 CAN_L
Table 2: OBDII pin configuration (showing only connected pins).
Kvaser AB, Mölndal, Sweden — www.kvaser.com

Kvaser U100S-X3 User’s Guide 10 (24)
Figure 6: OBDII CAN connector pinout.
3.5 CAN bus termination
Every CAN bus must be terminated with a 120 Ohm resistor at each end of the
bus. The Kvaser U100S-X3 does not contain any CAN bus termination, because
their inclusion could cause severe disturbance in a system which is already
correctly terminated.
For laboratory or testing use, the exact value of the termination resistors is not
always critical. Sometimes a single terminator is sufficient. For production, proper
termination is essential. If you see error frames on the bus, you should check the
termination.
To save yourself a lot of trouble, always terminate the CAN
bus properly.
3.6 Power supply
The Kvaser U100S-X3 is powered through the USB connector. Make sure the USB
power source can supply enough current (500 mA). If using a USB hub, choose an
externally powered one to be safe.
Kvaser AB, Mölndal, Sweden — www.kvaser.com
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Kvaser Interfaccia USB
Manuali Interfaccia USB popolari di altre marche

PASCO
PASCO SCIENCEWORKSHOP 750 Manuale utente

Phonic
Phonic FIREFLY 302 USB Manuale utente

OHAUS
OHAUS Scout STX Series Manuale utente

Denon
Denon DN-HC4500 - DJ Mixer USB Controller Manuale utente

Lutron Electronics
Lutron Electronics Stanza SZ-CI-USB-CPN5138 Manuale utente

Paradox
Paradox PMC5-TI00 Manuale utente