LEF LIGHTING NEXTA PLANO-LOCK Manuale utente

Electronic interface unit for devices with dry contact inputs (e.g. sectional doors or automated gates).
Power supply 12-32Vdc or 12-24Vac, Output contacts: 1A 30Vdc.
Integrated radio receiver for remote controls.
WiFi connection for OneSmart App.
PLANO-LOCK/ONE
OneSmart

INDEX
1 - PRODUCT FEATURES
1.1 - TECHNICAL DATA page 3
2 - CONNECTION DIAGRAMS
2.1 - START CONTACT CONNECTION DIAGRAM page 4
3 - USE OF THE CONTROL UNIT
3.1 - TYPICAL INSTALLATION
3.2 - USE VIA RADIO
3.3 - USE WITH SMARTPHONE APPLICATION
3.4 - USE WITH VOICE CONTROL
page 6
page 7
page 7
page 7
4 - CONTROL BY RADIOTRANSMITTERS
4.1 - RADIOTRANSMITTER SETTING
4.2 - DELETION OF RADIOTRANSMITTERS
page 8
page 9
5 - CONTROL WITH APP ONE SMART
5.1 - APP ONE SMART CONNECTION
5.2 - USE OF THE APP ONE SMART
page10
page 11
6 - CONTROL BY VOICE COMMANDS
6.1 - CONNECTION TO THE APP “GOOGLE HOME”
6.2 - CONNECTION TO THE APP “AMAZON ALEXA”
6.3 - CONNESSIONE ALL’APPLICAZIONE “AMAZON ALEXA”
page 12
page 13
page 14
7 - ADVANCED PROGRAMS
7.1 - VISUALIZATION OF THE STATE OF THE DOOR ON THE APP
7.2 - MANAGING THE DOOR LOCK FROM THE APP
7.3 - RESET
page 16
page 20
page 21
2

1 - PRODUCT FEATURES
1.1 TECHNICAL DATA
Connectors
cover
Button 1 Hidden key
Button 2
Led
Power supply 12-32 Vdc or 12-24Vac
Output One NO contact (1A 30Vdc) for start function
One NC contact (1A 30Vdc) for stopt function
Status signaling inputs 1 input for open automation signaling dry contacts,
1 input for close automation signaling dry contacts
N° of programmable
transmitters 30
RF receiver frequency 433.920MHz
WiFi frequency 2.4GHz
Protection rating IP20
Working temperature -20° +55°
Box dimensions 80 X 80 h16 mm
3
80
80 16

2 - CONNECTION DIAGRAMS
RECOMMENDATIONS
• Installation must be carried out only by professional technicians in accordance with the applicable electrical and
safety regulations.
• All connections shall be operated without electrical voltage.
• Use proper cables.
• Don’t cut the antenna
• Provide in the power line twith an appropriate disconnection device
• Dispose of waste materials in full compliance with local law.
• Do not exceed the specied load limits and use correctly protected power supplies.
2.1 CONNECT THE START CONTACT
Start contact must be connected to the “start contact” of the automation control unit.
WARNING:
• Contact must be free of voltage
-
+
- = (1)
+ = (2)
NO start contatc = (3)
Common of the contact = (4)
Antenna = (10)
(2)
(1)
(3) (4)
Automation
control unit
Start input
(NO contact)
12 - 32 Vdc
or 12-24 Vac
4

USE VIA WIRE
The start contact of the Plano control unit is connected in parallel to any wire commands (e.g. buttons or key selectors)
directly to the automation control unit.
USE VIA RADIO TRANSMITTER
To send start command via radio transmitter, you need to program it on the Plano control unit, see paragraph 5
USE VIA APP
In order to send start commands from application, it is necessary to do the procedure for associating the control unit with
the application, see paragraph 6.
Once the device is associated, it will be present on the home.
Once selected, automation can be remotely controlled:
SLIDE TO START
DEVICE OPTION
WARNING:
• The effect of the START command (open, close, open/stop/close) depends on the automation control unit settings
5

3 - USE OF THE CONTROL UNIT
3.1 TYPICAL INSTALLATION
The system can be controlled by a radio commands, smartphone App OneSmart or voice commands.
The installation can operate with only radio controls or application only.
Instead, to use voice commands, at least the App conguration must be completed.
CONTROL UNIT
VOICE CONTROL
CONFIGURATION
See paragraph 6
APP CONTROL
CONFIGURATION
See paragraph 5
RADIOTRANSMITTER
CONFIGURATION
See paragraph 4
ROUTER WITH INTERNET
CONNECTION
6

3.2 USE VIA RADIO
To control the automation via radio you must have compatible transmitters and therefore must carry out the association
procedure, see paragraph 4.
3.3 USE VIA SMARTPHONE APP ONESMART
The conguration procedures described in paragraph 5 above must be followed to control the lights by smartphone App.
3.4 USE WITH VOICE CONTROL
The conguration procedures described in paragraph 6 above must be followed to control the lights by voice commands.
7

STEP 1
Press the button 1.
The led turns on red.
STEP 2
Within 60 seconds make a transmission with the transmitter
to be saved.
See transmitter manual, the paragraph entitled “transmitter
programming” for specify information.
The led makes 3 Flashes and turns off.
4.1 - RADIO PROGRAMMING
This procedure lets you programme compatible multifunctional or generic transmitters.
ACTION: Short press of button 1 LED: Turns on red
ACTION: Make a transmission with the transmitter LED: Flashes 3 times
4 - MANAGEMENT WITH REMOTE CONTROL
This procedure lets you programme/delete compatible 433.92MHz transmitters.
Multifunctional transmitters, codes:
With multifunctional transmitters the transmitter control modes depend on the model used.
Generic (wireless bus) transmitters, codes:
The functions of the generic transmitters is “start of the automation”.
8

STEP 1
Hold the receiver button 1 down (about 5 seconds.) until the
LED begins to Flash.
DELETION OF SINGLE
TRANSMITTER
DELETION OF ALL
TRANSMITTER SAVED
4.2 - DELETION OF REMOTE CONTROL
These procedures let you delete from the memory transmitters that have already been programmed.
STEP 2a
Within 10 seconds make a transmission with the
transmitter that you want to delete.
The LED ashes quickly and turns off.
STEP 2B
Within 10 seconds press the button 1 on
the receiver for a short time to conrm the
delection of all transmitters.
The LED starts ashing quickly and turns off.
ACTION: Hold tbutton 1 down LED: Flashes red
ACTION: Make a transmission with the transmitter
LED: Flashing quickly and turns off
ACTION: Short press of button 1
LED: Flashing quickly and turns off
9

4. Select the category
“Smart Devices”
1. Download the App OneSmart on the phone 2. After starting the
application, you will need to
create an account.
Complete the procedure.
3. Press the
“Add Devices” icon
5. Press the button 2 on the control unit until the
blue led is turned on, then release the button. After
a few seconds the led and the load will start to ash
6. Press “Connect”
on the App
5 - CONTROL WITH APP ONE SMART
These procedures allow you to manage the light from your device (example: mobile phone) through the application and to
control the system remotely.
5.1 - APP CONNECTION
This procedure connects the control unit Plano-One to the application. It shall be repeated for each control unit on the
installation.
ATTENTION: an internet-based wi- network is required for te operation.
8. The device will be now automatically congured. The blue
led on the control unit indicates the progress of the setting:
Series of one Flash = the power station is ready for setup,
Series of two Flashes = power station is trying to connect to
the WiFi network,
Series of 4 Flashes = the power station connected correctly.
The LED will die after two minutes.
FOR WIFI CONNECTION ISSUES CHECK OUT PG. 23
7. On the application,
select the wi- network,
insert the network
password and conrm
10
OneSmart
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali LEF LIGHTING Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente