Magnescale MG80-PN Manuale utente

MG80-PN
Operating Manual
PROFINETInterfaceModule
Read all the instructions in the manual carefully before use and strictly follow them.
Keep the manual for future references.

1
Table of contents
Table of contents ..................................................................................................................... 1
Revision history....................................................................................................................... 2
1. Introduction...................................................................................................................... 3
2. Basic information ............................................................................................................ 4
2.1. System configuration.................................................................................................. 4
3. Setting ................................................................................................................................ 5
3.1. Download of setting application and GSDML file ................................................... 5
3.2. About IO data .............................................................................................................. 5
3.3. Setting various parameters ....................................................................................... 5
3.3.1. Connection ............................................................................................................ 6
3.3.2. Setting method........................................................................................................ 7
3.3.3. Restart MG80-PN ................................................................................................. 13
4. Specifications.................................................................................................................. 14
4.1. Interface specifications ............................................................................................ 14
4.2. LED indicator.............................................................................................................. 15
5. Function ........................................................................................................................... 17
5.1. Functions list.............................................................................................................. 17
5.2. Frame definition ........................................................................................................ 18
5.3. Detail of function....................................................................................................... 19
5.3.1. Peak hold............................................................................................................. 19
5.3.2. Pause.................................................................................................................... 20
5.3.3. Start ..................................................................................................................... 20
5.3.4. Reset .................................................................................................................... 20
5.3.5. Preset................................................................................................................... 20
5.3.6. Master preset...................................................................................................... 20
5.3.7. Comparator......................................................................................................... 21
5.3.8. Add/Sub function ............................................................................................... 21
5.3.9. I/O module control ............................................................................................ 22
6. Communication.............................................................................................................. 23
6.1. Communication with PROFINET device (IO controller) ..................................... 23
6.1.1. RT communication(Real-time communication)......................................... 23
6.1.2. NRT communication (Non Real-time communication) ................................ 33
6.1.3. NRT communication command list ................................................................. 34
7. Appendix.......................................................................................................................... 55
7.1. Parameter list............................................................................................................. 55

2
Revision history
Revision
Date
Description
Pages
1.00
2020/07/27
All
1.01
2020/10/28
Corrections of errors and additions
All

3
1. Introduction
MG80-PN is an interface unit main module that can easily acquire multi-axis
measurement data by connecting to a PC or PLC via PROFINET interface.
It is compatible with the existing product MG70-PN in terms of communication.
When using MG70-PN, the program used in MG80-PN can be used continuously.
This manual describes the details of the functions and the communication setting
method.
For MG80-PN, MG80-CM and LZ80, refer to the attached instruction manual of each
device.
For basic information of PROFINET, refer to the manual of each PLC manufacturer.

4
2. Basic information
In PROFINET, the master device is called a “IO controller” and the slave device is
called an “IO devices”. MG80-PN belongs to IO Devices.
This section describes the connection configuration of MG80-PN and various
connected devices.
2.1. System configuration
MG80-PN can be connected to a counter module MG80-CM for connecting a
measuring unit, and an I/O module LZ80-K1/K2 that can control the operation of
the constituent units and external signals.
Master
PC, PLC
PROFINET or
Ethernet cable
(MG80-PN side
RJ45 connector)
Measuring unit
Maximum configuration (1unit)※:
MG80-PN×1, MG80-CM×16, LZ80-K1/K2×2
※Up to 255 units (4080axis) can be connected
Measuring unit No. 1・・・・・・・・・・・15 16
・Up to 16 counter module MG80-CM can be connected to one MG80-PN.
・Connect the measuring unit DK series to MG80-CM.
・Measuring unit numbers are automatically assigned in order from 1 closest to MG80-PN.
・For PROFINET or Ethernet connection, prepare a shielded cable with
RJ45(8P8C) connector. (Both straight and cross cables can be used.)
・The number of connectable units depends on the available number of 1(0x01)to 255(0xFF),
in which the lower 1byte of the IP address can be set.
If the IP address can use 1 to 255, maximum 255 units (4080 axes) can be connected.
・Be sure to use Port 1 for PROFINET connection with the master side and host side.

5
3. Setting
3.1. Download of setting application and GSDML file
1. Access to Magnescale Web
(https://www.magnescale.com/mgs/language/english/)
「Products」
→「Digital Gauge」
→「MG80-NE/EI/PN MG80-CM」
→「Software」
Download the Setting application from “Setting application for Windows PC”
As above
「Products」
→「Digital Gauge」
→「MG80-NE/EI/PN MG80-CM」
→「Software」
Download the GSDML file from “Setting file”
GSDML file can be used regardless of the PLC manufacture and the number
of axes used.
2. Save the file in an appropriate location and extract it with decompression
software.
3.2. About IO data
When the GSDML file is imported into the development environment, the IO data
is handled as Byte array data. Please refer to “6. Communication” page of the
text for IO data mapping.
3.3. Setting various parameters
Various settings of MG80-PN can be performed from PC by using
“Setting application for Windows PC”

6
3.3.1. Connection
1. Preparation of "setting application for Windows PC"
Please place the downloaded "MG80SettingTool.exe" file in an arbitrary
location.
2. Make the following settings on the PC which “the setting application for
Windows PC” is installed.
IP address :192.168.100. xxx※1
Subnet mask :255.255.255.0
※1 Address that cannot be set to XXX
- “1” that is used when setting with the MG80-PN.
- Same address as other connected devices.
3. Set the setting switch to “0x00” to enter the setting mode and enable
communication with the computer.
In this case, the IP address is fixed to the following.
IP address :192.168.100.1
Subnet mask :255.255.255.0
4. Connect the PC which “Setting application for Windows PC”” is installed and
MG80-PN directly with Ethernet cable.
Connect the power supply and turn on the MG80-PN.
5. Click "MG80SettingTool.exe" on the PC on which "Setting application for
Windows PC " is installed to start the application.
IP address
Lower 1 byte setting switch: 0x00
LAN (100base-TX)
TCP/IP
< Setting application for Windows PC>
Change IP address
ex): 192.168.100.10

7
3.3.2. Setting method
Set various operation parameters using the “Setting application for Windows PC”.
“ MG80ModuleSettingTool.” installed on the PC is started, the following screen
appears.
Network settings (do not use)
Connection
Parameter settings

8
Follow the steps below to connect to the setting application for Windows PC.
1. Click the Start button at the top right of the setting application.
2. Click the Connect button at the top right of the setting application.
3. If the connection is successful, the network setting field and parameter setting
field become valid.
If the connection fails, turn off the power of the MG80-PN and start again from the
setting application.

9
3.3.2.1. Measurement parameter setting
Check that the following parameter setting fields are active.
If not, redo the connection procedure described in the previous section.
If there are multiple pages on each parameter screen, switch pages by pressing the
page forward buttons.
After setting the parameters on each parameter screen, click the “Set” button at the
bottom of the screen to send and save the parameters to MG80-PN
Note) If you do not click the “Set” button, it will not be saved in MG80-PN, so
be sure to execute it on each screen.
By pressing the “Get” button at the bottom of each parameter screen, you can get
the parameters currently saved in MG80-PN.
Indice
Altri manuali Magnescale Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente