Meriam PIT5000 Manuale utente

The PIT5000: Pipeline Integrity Tester
A Pipeline Hydrostatic Testing Device

Introductory information
Notification Statements
Disclaimer
Copyright

Notification Statements (continued)
Voids the computer warranty
Patent and trademark information
Patent statement
Trademark statements

Safety Information
Preventing injury
Safety Symbols
Safety Symbols
Safety Symbols
Explaining the symbols
This is the Read Instruction Manual symbol. This symbol
indicates that you must read the instruction manual.
Indicates a potentially hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
could result in minor or moderate injury.
Indicates information essential for proper product installation,
operation or maintenance.

For your safety
Fire and/or explosion hazard
Control Panel
Power connections: DC and AC
Pressure limits and power issues
Specifications
Hazardous voltage inside.
Risk of electric shock or burn.
The control panel should only be removed by
authorized electrical technicians.

Protect the PIT5000
Protect the PIT5000
Do not substitute parts

Contents
A Pipeline Hydrostatic Testing Device..............1
Introductory information..................................2
Notification Statements......................2
Notification Statements (continued)..3
Patent and trademark information ....3
Safety Information ..............................4
Safety Symbols....................................4
For your safety.....................................5
Protect the PIT5000............................6
Contents ..............................................7
Meriam Contact Information ..............8
Glossary ...............................................9
Receiving, unpacking, and setting up the
PIT5000.........................................................11
Receiving and unpacking .................11
Hardware .......................................................12
Recommended power connections .12
Temporary power connections .........13
Connecting the 12 V battery.............14
Computer mounting panel................15
Control panel .....................................16
Software ........................................................23
First—Check the computer’s time ....23
Second—zero the pressure ...............25
Flexibility in the PIT5000 application
............................................................25
The main tabs in the application......25
Setup tab ...........................................26
Report 2—the enhanced report........35
Data Panel .........................................36
Data Panel (continued) .....................37
Data Panel (Continued).....................38
Add Note button ............................... 39
End Test button ................................ 40
Strip Chart tab .................................. 41
Strip Chart tab (continued) .............. 42
Data tab ............................................ 43
Details tab......................................... 44
Details tab (reset, calibration, paths)
........................................................... 45
Details tab (do not delete these files)
........................................................... 46
Stroke Count tab .............................. 47
Stroke Count tab (continued) .......... 48
Stroke Count tab (continued) .......... 49
Stroke Count tab (continued) .......... 50
Shut down and disconnect .............. 51
Appendices ................................................... 52
Returning for repair or calibration .. 52
Troubleshooting Guide..................... 53
Specifications ................................... 55
Specifications (continued) ............... 56
Part numbers.................................... 57

Meriam Contact Information
Meriam
Address
Meriam
10920 Madison Avenue
Cleveland | Ohio | 44102
USA
Telephone
US customers: (800) 817-7849
International customers: + 1 216 281 1100
Fax
US customers: + 1 216 281 0228
International customers: + 1 216 281 0228
E-mail addresses
Departments
E-mail addresses
Return Material Authorization /
Service & Repair Department
Sales
Website
www.Meriam.com
Local Meriam Representatives
Find a local Meriam
representative
Use this link to help you find Meriam representative on this
world map: REP LOCATOR.
Or, you may use this full website address to go to the same
location: http://www.meriam.com/representatives-map/

Glossary
Words and phrases
Definitions
12 V car adapter cable
Also known as a cigarette lighter adapter. This is an optional cable
with DC-to-DC sockets.
Autoscale Graph
The Autoscale function automatically rescales the axes of the
currently selected graph based on the data it receives.
By default, autoscaling is always on.
Button or key
A button always refers to an area on the screen that you can
click to select functionality.
A key always refers to hardware push buttons on the keyboard
that you can press.
Control Panel
The Control Panel is located in the bottom of the carrying case. It
has the keyboard and these labeled areas: Power, Computer, and
Measure.
Data Panel
The Data Panel displays in the PIT5000 application on the right
side in all tabs. The panel displays different information including
flashing red alarms and the following four buttons: Start Program,
Begin Test, End Test, and Add Notes.
Digital Counter
A digital I/O device that provides 5 volts to the stroke counter and
converts the stroke count to a digital signal to the computer via
USB.
Dry contact set
The contacts in a Dry contact set do not have electrical power on
them. The dry contacts are for the (non-supplied) pump stroke
counter.
Edit box
Edit boxes (also known as fields) are for you to enter your data.
M12 connectors (M & F)
Male NPT
NPT is an abbreviation of National Pipe Thread (Tapered). This is a
standard male tapered pipe thread.
PIT5000
PIT is an acronym for Pipeline Integrity Tester.
P Leak Pressure
P Leak Pressure refers to Preliminary Leak Test Pressure. Some
customers perform a 15-minute leak test before going to higher
pressures.
Pressure
Pipe
You may see different ways of expressing these concepts in
printed material, on the PIT5000, and in the software. The most
common are:
Press
P Leak and PLeak
PTest

Words and phrases
Definitions
PTest Instrument Pressure
PTest is an abbreviation of the words Pressure Test.
Instrument Pressure refers to the pressure of the PIT5000
device.
Quick-test connection
The Quick-test connection is located on the Control Panel in the
Measure pane.
RTD
RTD is an abbreviation of Resistance Temperature Detectors.
Strip Chart
Strip Chart is a tab in the PIT5000 application that displays a live
plot of pipe pressure (Press), ambient temperature (T-Amb) and
pipe temperature (T-Pipe) versus time in order to record the
hydrostatic test and its duration.
Stroke Count versus
Stroke Counter
Stroke Count refers to number of recorded pump strokes.
Stroke Counter refers to the digital counter that records pump
strokes. It is connected to the pump using the Stroke Counter
cable.
Temperature
Ambient
You may see different ways of expressing these concepts in
printed material, on the PIT5000, and in the software. The most
common are:
Tambient
T ambient
T-Amb
T Amb
Ambient Temp
Temperature
Pipeline
You may see different ways of expressing these concepts in
printed material, on the PIT5000, and in the software. The most
common are:
Pipeline Temp
Pipe Temperature
Pipe temp
T
T-Pipe or T-pipe
T Pipe
Tpipe
V dc
Volts direct current.
V ac
Volts alternating current.
Indice
Altri manuali Meriam Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione

















