Michell Instruments CDP301 Manuale utente

CDP301 – Condumax
Dew-Point Tester
User’s Manual
97585 Issue 1
June 2020

Please ll out the form(s) below for each instrument that has been purchased.
Use this information when contacting Michell Instruments for service purposes.
Analyzer
Code
Serial Number
Invoice Date
Location of Instrument
Tag Number
Analyzer
Code
Serial Number
Invoice Date
Location of Instrument
Tag Number
Analyzer
Code
Serial Number
Invoice Date
Location of Instrument
Tag Number

© 2020 Michell Instruments
This document is the property of Michell Instruments Ltd and may not be copied or
otherwise reproduced, communicated in any way to third parties, nor stored in any Data
Processing System without the express written authorization of Michell Instruments Ltd.
CDP301 Dew-Point Tester
For Michell Instruments' contact information please go to
www.michell.com

CDP301 Dew-Point Tester User’s Manual
iv 97585 Issue 1, June 2020
Contents
Safety ...............................................................................................................................vii
Electrical Safety .................................................................................................................vii
Pressure Safety .................................................................................................................vii
Toxic Materials ...................................................................................................................vii
Repair and Maintenance .....................................................................................................vii
Safety Conformity ..............................................................................................................vii
Abbreviations .................................................................................................................... viii
Warnings .......................................................................................................................... viii
1 INTRODUCTION ................................................................................................1
1.1 Sample Gas Path .....................................................................................................1
1.2 Operating Overview .................................................................................................2
1.3 User Display and Interface .......................................................................................2
1.4 Calibration ..............................................................................................................2
1.5 Storage Instructions ................................................................................................2
2 INSTALLATION ..................................................................................................4
2.1 Sample Gas Connections..........................................................................................5
2.2 Electrical Safety ......................................................................................................6
2.3 Hazardous Area Safety ............................................................................................7
2.4 Gas Sample Connections..........................................................................................8
2.4.1 Connecting the Michell Sample System (optional accessory) ............................. 8
2.4.2 Considerations when setting sample pressure and flow .................................... 9
3 OPERATION ....................................................................................................10
3.1 Menu Map ............................................................................................................ 11
3.2 User Interface ....................................................................................................... 12
3.2.1 Front Page A Navigation .............................................................................. 15
3.2.2 Front Page B Navigation .............................................................................. 17
3.2.3 Front Page C Navigation .............................................................................. 18
3.2.4 Configuration Page ...................................................................................... 20
3.2.4.1 Measurement Configuration Page ........................................................... 21
3.2.4.2 Logging Configuration Page ................................................................... 22
3.2.4.3 Site Labels ............................................................................................ 24
3.2.4.4 Display ................................................................................................. 25
3.2.4.5 Enhanced Analysis Modes ...................................................................... 26
3.2.4.6 Real Time Clock (RTC) ........................................................................... 27
3.2.4.7 Camera Configuration ............................................................................ 28
3.2.4.8 Battery Status ....................................................................................... 29
3.2.4.9 About ................................................................................................... 30
3.2.4.10 Service ................................................................................................. 30
4 SYSTEM START-UP AND MEASUREMENT PROCEDURE ........................................31
4.1 Taking a measurement .......................................................................................... 31
4.2 System Shut-Down Procedure ................................................................................ 32
4.3 Battery Replacement ............................................................................................. 33
4.4 Battery Charging (within the Dew-Point Tester) ....................................................... 33
4.5 Spare Battery Charging.......................................................................................... 34
4.6 Data Access .......................................................................................................... 35
5 MAINTENANCE ................................................................................................36
5.1 Calibration ............................................................................................................ 36
5.2 Filter Element Replacement ................................................................................... 36
5.3 Mirror Cleaning ..................................................................................................... 37
5.3.1 CDP301 Preparation .................................................................................... 37
5.3.2 Opening Measurement Cell .......................................................................... 38

CDP301 Dew-Point Tester User’s Manual
Michell Instruments v
5.3.3 Removing Particulates ................................................................................. 39
5.3.4 Removing Residue ....................................................................................... 40
5.3.5 Reassemble Sample Cell .............................................................................. 40
5.3.6 Check Mirror Cleanliness .............................................................................. 41
Figures
Figure 1 Dimensions and Gas Connections ..................................................................... 4
Figure 2 Michell Sample System .................................................................................... 8
Figure 3 Menu Map .................................................................................................... 11
Figure 4 Push Button Operation ................................................................................... 12
Figure 5 Initialization Screen ....................................................................................... 12
Figure 6 Front Page A – Default .................................................................................. 13
Figure 7 Front Page A – Quick Menu ............................................................................ 16
Figure 8 Front Page B – Pop Up................................................................................... 17
Figure 9 Front Page C – Main Page .............................................................................. 18
Figure 10 Still Image View ............................................................................................ 19
Figure 11 Full-screen Video View ................................................................................... 19
Figure 12 Log File View ................................................................................................ 20
Figure 13 Configuration Menu – Measurement Page ....................................................... 21
Figure 14 Configuration Menu – Logging Page ................................................................ 22
Figure 15 Configuration Menu – Site Label Page ............................................................. 24
Figure 16 Configuration Menu – Display Page ................................................................. 25
Figure 17 Wdp Image................................................................................................... 26
Figure 18 Split Screen Mode ......................................................................................... 26
Figure 19 Configuration Menu – RTC Page ..................................................................... 27
Figure 20 Configuration Menu – Camera Page ................................................................ 28
Figure 21 Configuration Menu – Battery Page ................................................................. 29
Figure 22 About Info .................................................................................................... 30
Figure 23 Remove Charger Cover .................................................................................. 33
Figure 24 Connect Charger Lead ................................................................................... 34
Figure 25 Spare Battery Charging .................................................................................. 34
Figure 26 USB Port ....................................................................................................... 35
Figure 27 Cleaning Accessories ..................................................................................... 37
Figure 28 Lid Removal .................................................................................................. 38
Figure 29 Display Opened ............................................................................................. 38
Figure 30 Camera USB Connection ................................................................................ 39
Figure 31 Camera Sensor In-line Connector ................................................................... 39
Figure 32 Checking the Mirror Surface ........................................................................... 39
Figure 33 Camera Assembly .......................................................................................... 40
Figure 34 Screw Tightening Order ................................................................................. 40
Appendices
Appendix A Technical Specications ..............................................................................43
A.1 Dimensions .................................................................................44
Appendix B Hazardous Area Certication ......................................................................46
B.1 Product Standards .......................................................................46
B.2 Product Certication .................................................................... 46
B.3 Global Certicates/Approvals ........................................................46
Appendix C Quality, Recycling, Compliance & Warranty Information ................................48
Appendix D Analyzer Return Document & Decontamination Declaration .......................... 50

CDP301 Dew-Point Tester User’s Manual
vi 97585 Issue 1, June 2020

CDP301 Dew-Point Tester User’s Manual
Michell Instruments vii
Safety
This manual contains all the required information to install, operate and maintain this product. It
should be read and understood prior to use. Installation and operation of this product should be
carried out by suitably competent personnel only and must be in accordance with the terms of this
manual and associated safety certificates. Incorrect installation and operation of this product for
other than its intended purpose will render all warranties void.
This product is intended for use in a Hazardous Area and is awarded an ATEX, IECEx and cQPSus
Certificate. The relevant certificates should be fully examined and understood prior to installation or
use of this product.
Electrical Safety
The instrument is designed to be completely safe when used with options and accessories supplied
by the manufacturer for use with the instrument.
Pressure Safety
DO NOT permit pressures greater than the safe working pressure to be applied to the instrument.
The specified safe working pressure is 100 barg (1450 psig). Refer to the Technical Specifications in
Appendix A.
Toxic Materials
The use of hazardous materials in the construction of this instrument has been minimized. During
normal operation it is not possible for the user to come into contact with any hazardous substance
which might be employed in the construction of the instrument. Care should, however, be exercised
during maintenance and the disposal of certain parts.
Repair and Maintenance
The instrument must be maintained either by the manufacturer or an accredited service agent. For
Michell Instruments’ contact information please go to www.michell.com.
Safety Conformity
This product meets the essential protection requirements of the relevant EU and US standards
and directives. Further details of applied standards may be found in the Technical Specifications in
Appendix A.

CDP301 Dew-Point Tester User’s Manual
viii 97585 Issue 1, June 2020
Abbreviations
The following abbreviations are used in this manual:
barg pressure unit (=100 kP or 0.987 atm) (bar gauge)
ºC degrees Celsius
ºF degrees Fahrenheit
DC direct current
g grams
in inch(es)
µm micrometer
m/sec meters per second
mA milliampere
mm millimetres
MPa megapascal
Nl/min normal litres per minute
Nm Newton meter
oz ounces
psig pounds per square inch
RH relative humidity
scfh standard cubic feet per hour
fps feet per second
T temperature
V Volts
Ω Ohms
ø diameter
Warnings
The following general warning listed below is applicable to this instrument. It is repeated
in the text in the appropriate locations.
Where this hazard warning symbol appears in the following
sections it is used to indicate areas where potentially
hazardous operations need to be carried out.

CDP301 Dew-Point Tester User’s Manual
Michell Instruments 1
INTRODUCTION
1 INTRODUCTION
The CDP301 provides battery-powered manual visual measurement of the hydrocarbon
dew point and water dew point of processed natural gas. It is the result of more than
30 years’ experience in the supply of Dew-Point Testers to the worldwide oil, gas and
petrochemical industry.
The system consists of a hydrocarbon and water dew-point sensor cell and control
electronics housed in an Exd enclosure. A sample gas handling system to prepare the
gas sample prior to entry into the CDP301 Dew-Point Tester can also be supplied. The
Dew-Point Tester is designed to be positioned close to the process sample test point
and is ATEX, IECEx and cQPSus compliant for use in a Zone 1 or 2 Hazardous Area and
Class I, Div 1 Hazardous Locations. See marking label located on the side of Dew-Point
Tester to identify approvals.
The enhanced cooled-mirror principle of the CDP301 allows easy detection of
hydrocarbon or water dew point with the ability to review what has been observed
later. Key components of the dew-point tester are measurement cell, metallised-ceramic
mirror with integrated PT1000 resistance thermometer, triple-stage TEC (thermo-electric
cooler), hi-resolution colour camera, colour LCD display, tactile button HMI, operation
and measurement electronics, and rechargeable battery pack.
Standard accessories include a wheeled transport/storage case (suitable for non-
hazardous/safe area locations only) and backpack (of anti-static material) to carry the
CDP301 and sampling system to the location of use. A universal AC supplied battery
charger is provided (which must only be operated in safe area location). Spare battery,
sampling system and sample hoses are also available as optional accessories.
1.1 Sample Gas Path
The CDP301 measurement system must be supplied with gas at the required pressure
and ow via a sample gas handling panel. Sample gas entry and exit ports pass the
gas through ame arrestors. The inlet connection has a ow restriction device
tted. This is a mandatory safety device that limits pressure rise within the
Exd enclosure in the event of a gas leak occurring. The ow restriction device
must not be removed.
The Dew-Point Tester system components are housed within a cast, copper free aluminium
EExd rated enclosure. The enclosure has a screw cover incorporating a sealed window.
It is chromate primed, polyester coated in black, and provides environmental ingress
protection to IP64/NEMA4X. An enclosure breather is tted in the form of an additional
ame arrestor. It is important that no pipe connection is made to this breather and that
no restriction is allowed to occur.
All sample wetted metallic parts are manufactured in AISI 316L stainless steel with
Viton soft parts that comply with the NACE standard MR-0175 (latest edition). Tube
ttings are twin ferrule Swagelok© compression type.

CDP301 Dew-Point Tester User’s Manual
297585 Issue 1, June 2020
INTRODUCTION
1.2 Operating Overview
The CDP301 is a manual visual instrument. It is designed to follow the requirements
as described in ASTM D1142 and ISO6327. Using a simple button push, the measured
hydrocarbon and water dew-point temperature, pressure, date and time are stored and
indexed for review and retrieval/download at a later date.
1.3 User Display and Interface
The CDP301 Display and User Interface (UI) is presented via the circular window of the
enclosure. The unit is operated using 5 buttons, which allows full control of the UI. The
cover is fully detachable for greater access into the enclosure for service. During normal
operation of the instrument the cover must remain fully secured.
1.4 Calibration
Prior to shipment, the cooled-mirror dew-point sensor within the instrument undergoes
stringent factory calibration using high purity hydrocarbon gas of known dew point.
Due to the inherent stability of the instruments, only periodic calibration maintenance
is required under normal operating conditions. (See Maintenance Section below.)
1.5 Storage Instructions
The CDP301 has been designed for the accurate manual visual detection of hydrocarbon
and water dew point within natural gas. In order for the Dew-Point Tester to be functional
upon use it should be stored in accordance with the guidelines below:
• The Dew-Point Tester must be housed in a sheltered area, out of direct
sunlight and rain.
• The Dew-Point Tester should be stored to minimize the possibility of
sitting in ground water.
• The temperature within the storage environment should be maintained
between 0 and +50°C (+32 and +122°F).
• The humidity within the storage environment must be non-condensing.
• The storage environment must not expose the Dew-Point Tester to any
corrosive elements.
• The Dew-Point Tester may stay assembled with its sample conditioning
system (if supplied).
• All process connections should remain disconnected.
• All protective coatings should remain in place until use.
For the period from rst use of the CDP301, the following precautions should be followed:
• The Dew-Point Tester and associated sampling system must remain
isolated from the process gas, and the enclosure should remain closed to
ensure ingress protection is maintained.
• At time of start-up the procedures contained in this manual must be
followed.
Indice
Altri manuali Michell Instruments Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione