Microsens MS450154PM-48 Manuale utente

MICROSENS GmbH & Co. KG - Kueferstraße 16 - 59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Introduction
Future proof Concept
The MICROSENS fiber to the office concept with the intelligent combination of fiber and twisted
pair cabling offers a long term and future proof investment.
Easy Installation
Due to the tool-less snap-in mounting the installation of the switches is made very easy and fast.
With this most compact system available on the market, the compatibility to the most common
manufacturers of building installation systems is given.
Optional Version with Power-over-Ethernet (PoE)
With the implementation of the IEEE802.3af standard it is possible to supply end devices such as
IP-telephones, Access Points and cameras direct with electrical from the installation switch. The
switch is able to operate either as a power source (Power Source Equipment = PSE) or can be
supplied with power (Powered Device = PD) over the TP-uplink.
Comprehensive Management
The integrated management offers the complete configuration, monitoring and administration
of all devices in the network via a powerful software packet, the MICROSENS Device Manager.
Additional features such as VLANs, Data prioritisation (QoS) and Power-over-Ethernet can be
configured individually.
Using the firmware upgrade option it is possible to expand the functionality of the switch
without any hardware changes (e.g. authentication, SNMP, Telnet, etc.).
Features
•Switch
Fan less Fast Ethernet 10/100 Mbps installation switch according IEEE802.3
Layer 2 non-blocking switch, wire speed forwarding, store-and-forward, ma. 1024 MAC
addresses, auto learning and aging, 1 MB RAM, Full Duplex Frame according IEEE802.3x
•Installation
Simple installation due to snap-in (without screws) into cable trunks and sub floor boxes,
small dimensions
•Power Supply
Integrated power supply 100-240 V AC, PoE Version with 48 V DC input (via external
power supply) for switch and Power-over-Ethernet, max. power consumption of the
switch 3.5 W (without PoE supply), PoE max. 60 W (4x 15 W per port)
Depending on the application the use of a power supply is complete unnecessary. The
switch is supplied with power direct via the PoE capable TP-uplink (Powered Device = PD)
•Twisted-Pair Ports
5x 10/100Base-TX (RJ-45), auto negotiation for the detection of the speed 10/100 Mbps
and half or full duplex, auto crossover for the automatic configuration of the pinout
enabling implementation of homogeneous cabling
Full Power-over-Ethernet function according IEEE802.3af on all ports
•Management
Integrated management agent, port based configuration via PC based Management Tool
for speed (10/100 Mbps), full/half duplex, auto negotiation, auto crossover and port
Power-over-Ethernet
Data prioritisation (Quality of Service): 4 priority levels, port based (hardware priority),
Tag based (IEEE 802.1p/Q VLAN-Tag), IP TOS-field (DiffServ. Codepoints)
•Firmware Options
SNMP, Telnet, RADIUS authentication, web based management
MICROSENS
Installation-Switch 45x45
with Twisted Pair Uplink

Installation-Switch 45x45 with TP-Uplink Page 2/6
MICROSENS GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
System Components
Port 4: 10/100Base-TX, PoE (PSE)
Port 2: 10/100Base-TX, PoE (PSE)
Port 3: 10/100Base-TX, PoE (PSE)
Port 1: 10/100Base-TX, PoE (PSE)
Port 5: 10/100Base-TX, PoE (PD)
Power Connector
Fig. 1: Connectors
Power Supply
There are two options for the power supply:
MS450150M: This model has an integrated power supply. 100 – 240 V AC is connected direct to
the screw terminal (3x 1.5 mm2).
MS450154PM-48: This model supports Power-over-Ethernet according IEEE802.3af. The power
supply is done by an external power supply (MS700675, not included at delivery). The power
supply has a max. output of 65 W and is supplying the switch and the PoE end devices (max. 4x
15 W).
Alternatively the switch (MS450154PM-48) can be supplied via the TP uplink and PoE with power
(Powered Device = PD). The received power (15.4 W class 0) is not only for the supply of the
switch, it can be used also for the supply of the connected end devices (port 1-4) acting as a
Power Source Equipment (PSE).
In this application the following has to be considered:
•for the power to the connected end devices (PSE) a max. power of
1x 7.5 W (class 2) or
2x 4 W (class 1) is available
•at the uplink port has to receive a minimum voltage of 46 V DC
Note: The end devices available on the market today are often not using the complete power
specified in their class. This allows the connection of end devices according class 3 or class 0,
because their real power consumption does not exceed the limit of the MICROSENS switch.
In this case the “Forces Mode” of the power mode is selected via the network management. The
power consumption at the ports is monitored permanent and if the limit of 10 W is reached the
specific port is switched off.

Installation-Switch 45x45 with TP-Uplink Page 3/6
MICROSENS GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Technical Specifications
Type Fast Ethernet Installation-Switch 45x45
5 Ports 10/100Base-TX according IEEE 802.3
for cable trunk/sub floor box mounting
Cable type STP-cable, 100 Ω, Category 5 with RJ-45 connector
Max. cable length 100 m
Data rate 10 or 100 Mbps
LED displays ON Ready for operation
L0 on: Link at Uplink-Port
flashing: Data transmitted on uplink port
FD off: Uplink connection half duplex
mode
flashing: Collision in half duplex mode
on: Uplink full duplex
each TP-Port 1..4:
Ln on: Link at Port n
flashing: Data transmitted on Port n
Power Supply Direct –current voltage 48 VDC (44 to 55 V DC)
max. 3.5 W for switch plus max. 4x 15.4 W
for the supply of connected end devices (PD)
Operating temperature 0°C to 50°C
Storage temperature -20°C to 85°C
Rel. humidity 5% to 80% non condensing
PoE optional (only MS450154PM-48 version)
Integrated controller according IEEE 802.3af:
- max. 15.4 W per port (by using an external power supply)
- max. 10 W total (in operation mode as Powered Device)

Installation-Switch 45x45 with TP-Uplink Page 4/6
MICROSENS GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Dimensions
90
45 45
57
33
33
45
Front Side
Bottom Side
Fig. 2: Dimensions

Installation-Switch 45x45 with TP-Uplink Page 5/6
MICROSENS GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Resetting of the Switch
It is possible to reset the Switch by using the two buttons, which are integrated in the RJ45
sockets of the ports 1 and 2.
The buttons have following functions:
Reset Factory Default
Reset / IP Confuguration
Fig.. 3: Position of the reset buttons
1. Reset / IP-Configuration
Reset:
The switch can be reset by short pressing of the relevant button. Then the last stored
configuration is loaded into the unit. The Management configuration such as IP address and unit
name is not changed.
Attention: During the reset the data transmission via the switch is interrupted
IP-Configuration:
Longer pressing (approx. 5 sec) of the relevant button causes the IP Configuration after the
done reset. Now the IP address and the unit name can be given in via a network computer with
started Device Manager Software.
2. Factory Reset
By continuously pressing of the relevant factory reset button while activity of the reset button
(port 1) all in the unit stored configuration settings are reset to factory adjustments. The
configuration of the agent like IP address and unit name will not be changed.
The “factory reset” is only relevant for the switch data, not for the integrated management
agent. Only port configurations, priorities and VLAN settings will be reset.

Installation-Switch 45x45 with TP-Uplink Page 6/6
MICROSENS GmbH & Co. KG - Kueferstraße 16 - D-59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Management
The Installation Switch is equipped with an integrated management agent. Variants without
integrated network management are not available. The functionality of the network
management is fixed by the installed firmware and can be updated via a TFTP upload.
The following interfaces are available:
Standard
Support of the Device Manager Software (version 3.35), SNMP traps, SNMP system table
(interface table)
Telnet (optional, MS200230)
Telnet Command Line Interface (CLI),
Device Manager Software from version 3.35, SNMP traps
SNMP (optional, MS200222)
Full SNMP support (standard and private MIB on CD), SNMP traps, support of the Device
Manager Software (version 3.35 and higher)
Following features can be configured via the network management::
•Hardware and access adjustments of the Switch
•Data prioritization (support of 4 Hardware Queues)
•VLANs (support of up to 16 VLANs)
•Power over Ethernet (on / off / forced mode)
Further Documentation
•Datasheet network management
•Datasheet installation accessories
Order Codes
Art.-No.
Description
Connectors
MS450150M Ethernet Installation-Switch 45x45
Twisted Pair Uplink, horizontal
5x RJ-45 10/100Base-TX
1x 3-pin 230 V AC
MS450154PM-48 Ethernet Installation-Switch 45x45
1310m Multimode SC, horizontal
4x RJ-45 10/100Base-TX (PSE)
1x RJ-45 10/100Base_TX (PD)
1x 3-pin 48 V DC
MS700675 Switching Power Supply 48V/1.35A 65W for
45x45 Power over Ethernet Switch, power
cable
1x 230 V AC
1x 48 V DC
MICROSENS reserves the right to make any changes without further notice to any product to improve reliability, function
or design. MICROSENS does not assume any liability arising out of the application or use of any product. 3105/He
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Microsens Interruttore

Microsens
Microsens MS653410MX Manuale utente

Microsens
Microsens MS453490M Manuale utente

Microsens
Microsens MS453526M Manuale utente

Microsens
Microsens MS657208PX Manuale utente

Microsens
Microsens MS657033X Manuale utente

Microsens
Microsens MS400870M Series Manuale utente

Microsens
Microsens 10Base-TX Scheda tecnica

Microsens
Microsens MS453510 Manuale utente

Microsens
Microsens Profi Line Modular SERIES Manuale utente

Microsens
Microsens MS415259M Manuale utente























