Milesight UC50 Series Manuale utente

Milesight IoT
UC50x Series
User Guide

2
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the
instructions of this operating guide.
The device must not be remodeled in any way.
Do not place the device close to objects with naked flames.
Do not place the device where the temperature is below/above the operating range.
Make sure electronic components do not drop out of the enclosure while opening.
When installing the battery, please install it accurately, and do not install the reverse or
wrong model.
The device must never be subjected to shocks or impacts.
Declaration of Conformity
UC50x series is in conformity with the essential requirements and other relevant provisions of
the CE, FCC, and RoHS.
Copyright © 2011-2021 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual
shall copy or reproduce the whole or part of this user guide by any means without written
authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: 4/F, No.63-2 Wanghai Road,
2nd Software Park, Xiamen, China
Revision History
Date
Doc Version
Description
Jan. 20, 2021
V 1.0
Initial version

3
Contents
1. Product Introduction.................................................................................................................................4
1.1 Overview...........................................................................................................................................4
1.2 Features............................................................................................................................................4
2. Hardware Introduction............................................................................................................................. 4
2.1 Packing List..................................................................................................................................... 4
2.2 Hardware Overview........................................................................................................................ 5
2.3 Internal Interfaces...........................................................................................................................6
2.4 Dimensions(mm)............................................................................................................................ 7
3. Hardware Installation............................................................................................................................... 7
3.1 Hardware Switch.............................................................................................................................7
3.2 UC50x Installation...........................................................................................................................8
4. Operation Guide.........................................................................................................................................9
4.1 Log in the ToolBox..........................................................................................................................9
4.1.1 NFC Configuration...............................................................................................................9
4.1.2 USB Configuration.............................................................................................................10
4.2 LoRaWAN Settings....................................................................................................................... 12
4.3 Interface Settings......................................................................................................................... 14
4.3.1 RS485 Settings.................................................................................................................. 15
4.3.2 RS232 Settings.................................................................................................................. 18
4.3.3 GPIO Settings.....................................................................................................................18
4.3.4 AI Settings.......................................................................................................................... 20
4.4 Maintenance..................................................................................................................................22
4.4.1 Upgrade.............................................................................................................................. 22
4.4.2 Backup................................................................................................................................ 23
4.4.3 Reset to Factory Default.................................................................................................. 24
5. Milesight IoT Cloud Management........................................................................................................25
5.1 Add a Milesight Gateway.............................................................................................................25
5.2 Add UC50x to Milesight IoT Cloud.............................................................................................26
6. Device Payload........................................................................................................................................27

4
1. Product Introduction
1.1 Overview
UC50x series is a LoRaWAN®controller used for data acquisition from multiple sensors. It
contains different I/O interfaces such as analog inputs, digital inputs, digital outputs, serial ports
and so on, which simplify the deployment and replacement of LoRaWAN®networks.
UC50x series can be easily and quickly configured by NFC or wired USB port. For outdoor
applications, it provides solar or built-in battery power supply and is equipped with IP67-rated
enclosure and M12 connectors to protect itself from water and dust in harsh environments.
1.2 Features
Easy to connect with multiple wired sensors through GPIO/AI/RS232/RS485 interfaces
Long transmission distance up to 11km with line of sight
Waterproof design including IP67 case and M12 connectors
Solar powered and built-in battery optional
Quick wireless configuration via NFC
Compliant with standard LoRaWAN®gateways and network servers
Quick and easy management with Milesight IoT Cloud solution
2. Hardware Introduction
2.1 Packing List
1 × Quick Guide
1 × DC Power Cable
(UC501 only)
1 × Solar Panel Kit
(UC501 Optional)
2 × Hose Clamps
(Optional)
If any of the above items is missing or damaged, please contact your sales Representative.
1 × U50x Device
2 × Data Cables
1 × Mounting
Bracket
Wall Mounting
Kits
1 × Warranty
Card

5
2.2 Hardware Overview
UC501 UC502
Data Interface 1:
Pin
Description
1
5V/9V/12V(Switchable)
2
3.3V
3
GND
4
GPIO1
5
GPIO2
6
RS232/RS485(Switchable)
7
8
Reserved
Pin
RS232
RS485
6
TXD
A
7
RXD
B
Data Interface 2:
Pin
Description
1
5V/9V/12V(Switchable)
2
3.3V
3
GND
4
Analog Input 1
5
Analog Input 2
6
Reserved

6
Power Interface (UC501):
Pin
Description
1
VCC(5-24V)
2
GND
2.3 Internal Interfaces
DIP Switch:
Interface
DIP Switch
Power Output
12V: 1 on 2 off 3 off
9V: 1 off 2 on 3 off
5V: 1 of 2 off 3 on
Analog Input
4-20mA ADC: 1 off 2 on 3 on
0-10V ADC: 1 on 2 off 3 off
RS485
Add 120 Ω resistor between A and B: 1 on 2 off 3 off
Add 1k Ω pull-up resistor on A: 1 off 2 on 3 off
Add 1k Ω pull-down resistor on B: 1 of 2 off 3 on
Note:
1) Analog inputs are set to 4-20mA by default, power outputs are set to 12V by default.
2) Power output on interface 1 is used for powering serial port devices, power output on
interface 2 is used for powering analog devices.

7
Power Button:
Function
Action
LED Indication
Turn On
Press and hold the button for more than 3s.
Off →On
Turn Off
Press and hold the button for more than 3s.
On -> Off
Reset
Press and hold the button for more than 10s.
Blinks.
Check
On/Off Status
Quickly press the power button.
Light On: Device is on.
Light Off: Device is off.
2.4 Dimensions(mm)
3. Hardware Installation
3.1 Hardware Switch
When using the analog input or power output of UC50x series, please follow the steps to switch
the working mode of hardware interface:
1. Remove the screw caps and take off the roof cover.
2. Change DIP switches that are related analog inputs and power outputs as shown in Section
2.3.
3. Put back the roof cover and screw the screws.
Note: Please turn off the device before changing DIP switches.

8
3.2 UC50x Installation
Wall Mounting
Make sure you have wall mounting bracket, bracket mounting screws, wall plugs, wall mounting
screws and other required tools.
Steps:
1. Mount the enclosure to the mounting bracket with the bracket mounting screws.
2. Align the mounting bracket horizontally to the desired position on the wall, use a marker pen
to mark four mounting holes on the wall, and then remove the mounting bracket from the wall.
Note: The connecting lines of adjacent points are at right angles.
3. Drill the four holes by using your drill with a 6 mm drill bit on the positions you marked
previously on the wall.
4. Insert four wall plugs into the holes respectively.
5. Mount the mounting bracket horizontally to the wall by fixing the wall mounting screws into
the wall plugs.
Pole Mounting
Make sure you have wall mounting bracket, bracket mounting screws, hose clamp and other
required tools.
Steps:
1. Mount the enclosure to the mounting bracket with the bracket mounting screws.

9
2. Loosen the hose clamp by turning the locking mechanism counter-clockwise.
3. Straighten out the hose clamp and slide it through the rectangular holes in the mounting
bracket, wrap the hose clamp around the pole.
4. Use a screwdriver to tighten the locking mechanism by turning it clockwise.
4. Operation Guide
4.1 Log in the ToolBox
UC50x series can be monitored and configured via ToolBox APP or ToolBox software. Please
select one of them to complete configuration.
4.1.1 NFC Configuration
Preparation:
Smartphone (NFC supported)
Milesight ToolBox APP: V1.3.9 and above
Steps:
1. Download and install from Google Play or Apple Store.
2. Enable NFC on the smartphone and open“Milesight ToolBox” APP.
3. Attach the smartphone with NFC area to the device to read basic information.
4. Basic information and settings of devices will be shown on ToolBox if it’s recognized

10
successfully. You can turn on/off the device by tapping the button on the Device Status. In order
to protect the security of devices, password validation is required when configuring via unused
phone . Default password is 123456.
5. Tap “Read” button to check current status of device.
6. Tap “Write” button to write all your settings to the device.
Note:
1) Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
2) If the smartphone fails to read/write configurations via NFC, keep the phone away and back
to try again.
3) UC50x series can also be configured by dedicated NFC reader, which can be purchased from
Milesight IoT.
4.1.2 USB Configuration
Preparation:
Type-C USB cable
PC (Windows 10 is recommended)
ToolBox: V6.35 and above
Altri manuali per UC50 Series
3
Indice
Altri manuali Milesight Controllori

Milesight
Milesight UC50 Series Manuale utente

Milesight
Milesight UC51 Series Manuale utente

Milesight
Milesight WS558 Manuale utente

Milesight
Milesight UC51 Series Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC11 Series Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC100 Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC50 Series Manuale utente