Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the
instructions of this operating guide.
The device must not be remodeled in any way.
Do not place the device close to objects with naked flames.
Do not place the device where the temperature is below/above the operating range.
Make sure electronic components do not drop out of the enclosure while opening.
When installing the battery, please install it accurately, and do not install the reverse or
wrong model.
The device must never be subjected to shocks or impacts.
Declaration of Conformity
UC51x series is in conformity with the essential requirements and other relevant provisions of
the CE, FCC, and RoHS.
Copyright©2011-2021 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual
shall copy or reproduce the whole or part of this user guide by any means without written
authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: 4/F, No.63-2 Wanghai Road,
2nd Software Park, Xiamen, China
Revision History
Date
Doc Version
Description
Feb. 20, 2021
V 1.0
Initial version

3
Contents
1. Product Introduction.................................................................................................................................4
1.1 Overview........................................................................................................................................... 4
1.2 Features............................................................................................................................................4
2. Hardware Introduction..............................................................................................................................4
2.1 Packing List......................................................................................................................................4
2.2 Hardware Overview.........................................................................................................................5
2.3 Power Button................................................................................................................................... 5
2.4 Dimensions(mm)............................................................................................................................ 6
3. Installation..................................................................................................................................................6
4. Operation Guide.........................................................................................................................................8
4.1 Log in the ToolBox.......................................................................................................................... 8
4.1.1 NFC Configuration...............................................................................................................8
4.1.2 USB Configuration............................................................................................................... 9
4.2 Solenoid Valve Control.................................................................................................................10
4.3 LoRaWAN Settings....................................................................................................................... 11
4.4 Solenoid Settings.......................................................................................................................... 14
4.5 Maintenance.................................................................................................................................. 15
4.5.1 Upgrade...............................................................................................................................15
4.5.2 Backup.................................................................................................................................16
4.5.3 Reset to Factory Default...................................................................................................17
5. Milesight IoT Cloud Management........................................................................................................ 18
5.1 Add a Milesight Gateway............................................................................................................. 18
5.2 Add UC51x to Milesight IoT Cloud............................................................................................. 19
5.3 Solenoid Valve Control.................................................................................................................21
6. Device Payload........................................................................................................................................ 22

4
1. Product Introduction
1.1 Overview
UC51x series LoRaWAN®wireless solenoid valve controller is a device used to remotely control
DC latching solenoids of the valve. It contains 2 solenoid interfaces and 1 pulse interface, which
can be easily controlled locally or remotely.
Besides ultra-low-power LoRaWAN®technology, UC51x series also provides both solar and
built-in battery power supply for uninterrupted operation. For outdoor applications, it equips with
IP67-rated enclosure and M12 connectors to protect from water and dust under harsh
environments.
1.2 Features
Compatible with standard DC latching solenoids
OPEN/CLOSE control by mobile APP locally or commands remotely
One pulse water meter interface for flow monitoring
Transmission distance up to 11km with line of sight
Waterproof design including IP67 case and M12 connectors
Solar powered and built-in chargeable battery
Quick wireless configuration via NFC
Time and flow control via Milesight IoT Cloud
2. Hardware Introduction
2.1 Packing List
1 × Warranty Card
1 × Quick Guide
1 × Solar Panel Kit
(UC511 Optional)
2 × Hose Clamps
(Optional)
1 × U51x Device
3 × Data Cables
(1.5m)
1 × Mounting
Bracket
Wall Mounting Kits

5
If any of the above items is missing or damaged, please contact your sales Representative.
2.2 Hardware Overview
UC511 UC512
Solenoid Interfaces:
Pin
Description
1
GND
2
GPIO(for wiring switch)
3
CLOSE(Black)
4
OPEN(Red)
Pulse Interface/DC:
Pin
Description
1
GPIO2
2
VCC(5-24V)
3
GND
4
GPIO1
5
GND
6
GND
2.3 Power Button
Function
Action
LED Indication
Turn On
Press and hold the button for more than 3s.
Off →On
Turn Off
Press and hold the button for more than 3s.
On -> Off
Reset
Press and hold the button for more than 10s.
Blinks.
Check
On/Off Status
Quickly press the power button.
Light On: Device is on.
Light Off: Device is off.

6
2.4 Dimensions(mm)
3. Installation
Wall Mounting
Make sure you have wall mounting bracket, bracket mounting screws, wall plugs, wall mounting
screws and other required tools.
Steps:
1. Mount the enclosure to the mounting bracket with the bracket mounting screws.
2. Align the mounting bracket horizontally to the desired position on the wall, use a marker pen
to mark four mounting holes on the wall, and then remove the mounting bracket from the wall.
Note: The connecting lines of adjacent points are at right angles.
3. Drill the four holes by using your drill with a 6 mm drill bit on the positions you marked
previously on the wall.
4. Insert four wall plugs into the holes respectively.
5. Mount the mounting bracket horizontally to the wall by fixing the wall mounting screws into
the wall plugs.

7
Pole Mounting
Make sure you have wall mounting bracket, bracket mounting screws, hose clamp and other
required tools.
Steps:
1. Mount the enclosure to the mounting bracket with the bracket mounting screws.
2. Loosen the hose clamp by turning the locking mechanism counter-clockwise.
3. Straighten out the hose clamp and slide it through the rectangular holes in the mounting
bracket, wrap the hose clamp around the pole.
4. Use a screwdriver to tighten the locking mechanism by turning it clockwise.

8
4. Operation Guide
4.1 Log in the ToolBox
UC51x series can be monitored and configured via ToolBox APP or ToolBox software. Please
select one of them to complete configuration.
4.1.1 NFC Configuration
Preparation:
Smartphone (NFC supported)
Milesight ToolBox App: V1.3.9 and above
Steps:
1. download and install from Google Play or Apple Store.
2. Enable NFC on the smartphone and open“Milesight ToolBox” APP.
3. Attach the smartphone with NFC area to the device to read basic information.
4. Basic information and settings of devices will be shown on ToolBox if it’s recognized
successfully. You can turn on/off the device by tapping the button on the Device Status. In order
to protect the security of devices, password validation is required when configuring via unused
phone . Default password is 123456.

9
5. Tap “Read” button to check current status of device.
6. Tap “Write” button to write all your settings to the device.
Note:
1) Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
2) If the smartphone fails to read/write configurations via NFC, keep the phone away and back
to try again.
3) UC51x series can also be configured by dedicated NFC reader, which can be purchased from
Milesight IoT.
4.1.2 USB Configuration
Preparation:
Type-C USB cable
PC (Windows 10 is recommended)
ToolBox: V6.35 and above
Steps:
1. Download ToolBox from Milesight IoT website.
2. Open the case of UC51x and connect the UC51x to computer via type-C port.
3. Open the ToolBox and select type as “General”, then click password to log in ToolBox.
(Default password: 123456)

10
4. After logging in the ToolBox, you can click “Power On” or “Power Off” to turn on/off device
and change other settings.
4.2 Solenoid Valve Control
Solenoid valve can be controlled by ToolBox App or ToolBox software locally.
Via ToolBox Software:
Click “Open” or “Close” button on the “Status” page to change the status of solenoid valves.
Altri manuali per UC51 Series
2
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali Milesight Controllori

Milesight
Milesight UC50 Series Manuale utente

Milesight
Milesight UC51 Series Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC500 Series Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC300 Manuale utente

Milesight
Milesight UC11 Series Manuale utente

Milesight
Milesight UC100-868M Manuale utente

Milesight
Milesight UC100 Manuale utente

Milesight
Milesight UC300 Manuale utente