09/ 2007
Sub-display
Polarity indication
Battery condition indicator
Button (yellow), display lighting,
Button BAR, Bar graph centring and switchover of numerical value (4000/
20000),
Button PEAK H, (Peak hold), peak value storage,
Button AUTO H, (Auto-Hold), measured value storage,
Button (blue), for DC voltage/ direct current or AC voltage/ current (AC),
resistance measurement Ω or LVΩ, diode or continuity testing, frequency or
pulse ratio measurement, temperature measurement in °C or in °F,
Button M/M/A, storage of the highest, lowest measured values, and the
mean value,
Button REL ∆, relative value function,
Button RANGE, switchover automatic/ manual measuring range,
Rotary switch, for selecting the measurement function,
Jack (positive1), for V, Ω, Hz, °C,
COM jack, common socket for current voltage, resistance, frequency, tem-
perature, capacity measurement, continuity and diode testing,
Jack (positive1), for mA range, for currents up to 200 mA,
Jack (positive1), for 10 A range, for currents up to 10 A,
Rubber protective frame
Optical interface, for accommodating the adapter located on the data
cable,
1)
This is what the automatic polarity indication for DC current and voltage refers to
5. General information
5.1 General details on the multimeter
5.1.1 The digital display is a 3 ¾ or 4 ½ digit liquid crystal display with a
13 mm font size and decimal point. The largest display value is 4.000/
20.000.
5.1.2 The bar graph display comprises 42 segments.
5.1.3 The polarity indication is automatic. Only one polarity with respect to
the socket marked “-” is indicated.
5.1.4 The overranging is indicated by “0L” or “- 0L” and, in part, an acoustic
warning.
Warning, no indication and prior warning in the event of an overload
condition! A exceeding of dangerous contact voltage (> 60 V DC/ 30 V
AC rms) is indicated by an additional flashing symbol “”.
5.1.5 The 01 confirms each button press with a signal sound.
Invalid button presses are confirmed by a double signal sound.
In the event of an incorrect circuit of the jack for the mA / A range
the 01 warns with a signal sound and the indication
of in the display .
The acoustic alarm and the indication in the display extinguish
if a safety measuring cable is plugged into the jack for the mA or
A range and the corresponding current measurement range was
selected by means of the rotary switch .
The acoustic alarm and the indication in the display also appear
in the case of a defective fuse, if the safety measuring cable is plugged
into the jack for the mA or A-range and the corresponding current
measurement range was selected by means of the rotary switch .
5.1.6 The 01 features individual setting options which in part
remain active even after a shutdown. In order to change a setting,
press one of the following buttons and simultaneously activate the
01 from its “OFF” switch position.
Button- : Deactivates/ activates the automatic shutdown of the
background lighting after 15 minutes.
Button- 7:
Presetting of the nominal mains frequency (50 Hz or
60 Hz). This adjustment ensures improved stability
and accuracy in AC V mode. These settings are main-
tained even after the 01 is switched off.
The settings are modified only after a new presetting!
Button- :Presetting the temperature measurement in °C or °F.
The settings are modified only after a new presetting!
Button-BLUE : Deactivates/ activates the automatic switch-off after
approx. 30 minutes (APO, Auto-Power-Off).
Button- :Deletion of the internal measuring value memory (see
also Chapter 5.2)
Button- :Deactivates/ activates the fitted buzzer.
5.1.7 The button (yellow) switches on the display illumination. Shutdown
is effected by a renewed press of the button or automatically after 15
mins.