Display disappears on programmer:
- Check fused spur supply.
Heang does not come on:
- If the CH Indicator light is on then it is unlikely to be a fault with the programmer.
- If CH indicator light is NOT ON then check programme then try BOOST as this should
operate in any posion.
- Check that your room thermostat is calling for heat.
- Check that the boiler is on.
- Check that your pump is working.
- Check that your motorised valve if ed has opened.
Hot water does not come on:
- If the HW Indicator light is on then it is unlikely to be a fault with the programmer.
- If HW indicator light is NOT ON then check programme then try BOOST as this should
operate in any posion.
- Check that your Cylinder thermostat is calling for heat.
- Check that the boiler is on.
- Check that your pump is working.
- Check that your motorised valve if ed has opened.
If the problem persists contact your installer.
Note: If Service due soon or service due appears in display please contact your lan-
dlord.
...an Explanaon for Householders. Pro-
grammers allow you to set ‘On’ and ‘O’
me periods. Some models switch the
central heang and domesc hot water
on and o at the same me, while others
allow the domesc hot water and heang
to come on and go o at dierent mes.
Set the ‘On’ and ‘O’ me periods to suit
your own lifestyle. On some programmers
you must also set whether you want the
heang and hot water to run connuously,
run under the chosen ‘On’ and ‘O’ heang periods, or be permanently o. The me on
the programmer must be correct. Some types have to be adjusted in spring and autumn
at the changes between Greenwich Mean Time and Brish Summer Time. You may be
able to temporarily adjust the heang programme, for example, ‘Advance’, or ‘Boost’.
These are explained in the manufacturer’s instrucons. The heang will not work if the
room thermostat has switched the heang o. And, if you have a hot-water cylinder, the
water heang will not work if the cylinder thermostat detects that the hot water has
reached the correct temperature.
Please refer to the installing instrucons for any informaons about standards and pro-
duct environment.
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
In some instances the unit may have been set with the service interval funcon enabled.
By Law in rented accommodaon, your gas boiler should be inspected/serviced annual-
ly to ensure it is working correctly.
This opon is designed to remind the end user to contact the relevant person to have
the annual service carried out on the boiler.
This funcon will be enabled and programmed by your Installer, maintenance Engineer,
or Landlord.
If it has been set to do so, the unit will display a message on the screen to remind you
that a boiler service is due.
The Service Due Soon countdown will be indicated up to 50 days before the Service is
due to allow me to arrange for an engineer to aend, normal funcons will connue
during this stage.
At the end of this service due soon period, the unit will go to Service Due OFF at which
point only the 1hour boost will operate on TMR7 and PRG7, if the unit is a thermostat
RT1/RT7, it will operate at 20°C during this hour.
If PRG7 RF, Thermostat has no funcon.
NOTE
WHAT IS A PROGRAMMER ?