Numerik Jena SCM-1000 Manuale utente

USER MANUAL
English Original Instruction
SMART COMMUNICATION MODULE FOR LENGTH GAUGE ACANTO

Smart Communication Module
2/24
INDEX
1. FEATURES AND APPLICATIONS......................................................................3
2. SAFETY INFORMATION.........................................................................................4
2.1 General Information .................................................................................................4
2.2 Notes on Legal Requirements..................................................................................5
2.3 Notes on Transport, Storage and Handling..............................................................6
2.4 Notes on Operation..................................................................................................6
2.5 Environmental Protection and Disposal ...................................................................6
2.6 Scope of Delivery of SCM-1000...............................................................................6
3. TECHNICAL INFORMATION ................................................................................7
3.1 Technicalspecication .............................................................................................7
3.2 Technical drawing.....................................................................................................7
3.3 Nameplate................................................................................................................8
4. STATUS MESSAGES IN OPERATING MODE ..............................................9
5. INITIAL SETUP OF THE SMART COMMUNICATION MODULE.........10
5.1 Factory Settings .....................................................................................................10
5.2 Mechanical connections.........................................................................................10
5.3 Compatible software ..............................................................................................11
5.4 Commissioning of the Smart Communication Module ...........................................13
5.5 Changeofcustomer-specicsettings ....................................................................15
6. OPERATION OF THE SMART COMMUNICATION MODULE ..............16
6.1 Operation of the SCM with the SCA.......................................................................17
6.2 SCM output parameter ..........................................................................................19
6.3 ACANTO length gauge output parameter..............................................................20
6.4. Encoder settings ...................................................................................................20
7. APPLICATION PROGRAMMING INTERFACE ...........................................21
8. ORDER INFORMATION ........................................................................................21
9. SCM & SCA – TROUBLESHOOTING .............................................................21

Smart Communication Module
3/24
1. FEATURES AND APPLICATIONS
The SCM (Smart Communication Module) enables the conversion and data transfer of length
gaugesACANTOusingtheOpenPlatformCommunicationsUniedArchitecture(OPC)UAIoT-
protocol to transfer information to IT systems and IoT software.
OPC UA is a service-oriented industrial communication standard for secure and reliable data
exchange.Theprotocolisplatform-independentandenablesaseamlessowofinformation
betweendevicesfromdierentmanufacturers.OPCUAdenesthetransportofdataand
interfaces, security mechanisms and the semantic structure of the data, as well as services
for the exchange of data between clients and servers - including access to real-time data,
monitoring of alarms and events, access to historical data and other applications. This standard
is maintained and developed by the “OPC UA FOUNDATION”.
Essential features:
• Wireless data transmission up to 50 m
• Transmission of measured values, diagnostic data and evaluation numbers
• Identification and transfer of additional environmental information
(such as humidity, temperature, pressure)
• Use of the OPC UA communication structure
• Available for length gauge ACANTO (EnDat 2.2) in Europe.
Essential Benets:
• Cost-effective extension of networks, systems and applications
• Flexibility to integrate new devices into an existing network infrastructure
• Improved usability through wireless data transmission
• Data Improvement - Transparency for analysis and reporting at all IT levels
• Improved IT security through a sophisticated communication concept, protecting
against unauthorized data access
• Improved data availability and data security through a robust data architecture with
reliable communication mechanisms
• Reduction of downtimes due to predictive maintenance processes

Smart Communication Module
4/24
2. SAFETY INFORMATION
2.1 General Information
• Make sure to familiarize yourself thoroughly with the contents of the user manuals and
data sheets before installing and starting up the device!
• The devices as well as the accessory are guaranteed to function if the mounting and
operating conditions are maintained as stated in the respective user manuals and data
sheets .
• NUMERIK JENA GmbH is not liable for damages caused by unauthorized handling
of the devices and the accessory. Any unauthorized handling leads to forfeiture of all
warranty claims!
• NUMERIK JENA GmbH does not assume any liability for any damages or operating
errors caused by incorrect mounting and/or startup operations.
• Please consider user manuals, data sheets and safety instructions of devices from
other manufacturers which will be used in combination with encoders and accessories
from NUMERIK JENA to ensure a reliable operation.
• Please contact the support of NUMERIK JENA GmbH or an authorized representation
for further information. Please visit the NUMERIK JENA website to get the contact
information.
• Please pay attention to the safety instructions and warning symbols in the user manuals
and data sheets from NUMERIK JENA!
Danger to the device or to the function of the device!
Pull the plug!
Highlyinammable!

Smart Communication Module
5/24
Europe
2.2 Notes on Legal Requirements
Approval for radio transmission: For operation in radio mode.
NUMERIK JENA GmbH hereby declares that the SCM transmitter/receiver unit is in compliance
with the essential requirements and other relevant provisions of Directive 2014/53/EU.
The EC Declaration of Conformity can be requested from
NUMERIK JENA GmbH
Im Semmicht 4
07751 Jena
Germany
or www.numerikjena.de
Other countries on request.
USA FCC ID 2AC7Z-ESPWROOM32 -
THE DEVICE COMPLIES WITH PART 15 OF THE FCC RULES
This equipment radiates radio frequency energy and if not used properly - that is, in
strict accordance with the instructions in this manual - may cause interference to radio
communications and television reception.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Changesormodicationsnotexpresslyapprovedbythepartyresponsibleforcompliancecould
void the user‘s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
theequipmentoandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor
more of the following measures:
(3) Reorient or relocate the receiving antenna.
(4) Increase the separation between the equipment and receiver.
(5) Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
(6) Consult the dealer or an experienced radio/TV technician for help.

Smart Communication Module
6/24
2.3 Notes on Transport, Storage and Handling
The products from NUMERIK JENA GmbH must be transported and stored in the original
packaging only!
2.4 Notes on Operation
• The devices and accessories from NUMERIK JENA GmbH must be operated with the
supply voltage stated in the respective user manual or data sheet only.
• Comply with applicable PIN assignment if auxiliary electronic units are connected!
Do not connect or disconnect plugs if the power is on!
2.5 Environmental Protection and Disposal
Environmental damage due to incorrect disposal of the product, accessories or peripherals!
• Do not dispose in domestic waste.
• Dispose only by authorized collection points. Electrical waste and electronic components
are subject to special-waste regulations.
• Observe the applicable country-specific regulations.
More detailed information on legal regulations can be obtained from competent authorities.
2.6 Scope of Delivery of SCM-1000
The SCM-1000 comes with the following items:
• Smart Communication Module SCM-1000
• USB adapter cable, cable length 1.80 m
• Installation instructions
The current version of the data sheet is available in the download area at www.numerikjena.de.

Smart Communication Module
7/24
D24 59,65
48
3. TECHNICAL INFORMATION
3.1 Technical specication
TheSCM-1000complieswiththefollowingtechnicalspecication:
Table 1: Technical data of the SCM-1000
3.2 Technical drawing
Illustration 1: Technical drawing (all dimensions in mm)
Parameter SCM Unit
Interfaces USB 2.0
WiFi 802.11 b/g/n
Supply voltage 5.0 ± 10% V
Current consumption (max.) 165 mA
Samplerate Position (max.) 100 Hz
Weight 50 g
IP-rating (EN 60 529) IP50
Dimensions 59.65 x 24 mm
Operating temperature 0 to +55 (+32 to +131) °C (°F)
Storage temperature -20 to +70 (-4 to +158) °C (°F)
Shock [per 11 ms] ≤500(EN60068-2-27) m/s2
Vibration [within 55-2000 Hz] ≤100(EN60068-2-6) m/s2
Range (typical) 50 m

Smart Communication Module
8/24
3.3 Nameplate
Illustration 2: Figure of the SCM-1000 nameplate
Product Name
FCC-Declaration
Identity Number
Serial Number
Data Matrix Code

Smart Communication Module
9/24
LED status Length gauge connected Denition
Blue (steady) Yes Length gauge detected, SCM
operable
Red (steady) Yes SCM-1000 Error
Red(ashing) Yes Length gauge Error
please check the length gauge
Blue (steady) No Search for connected length
gauges
Red(ashing)/(steady) No Setup mode active; SCM-1000
initiated access point
M12 connector
(to connect the length gauge)
USB connector type Micro-B
(USB-power supply)
Status LED
4. STATUS MESSAGES IN OPERATING MODE
ThecurrentstatusoftheSCM-1000isindicatedbytheintegratedLED(checkgure3).
Illustration3:SchematicgureoftheSCM
Depending on the Smart Communication Modules status, the LED can assume one of
the following LED states (see table 2). Please note that the current state of assembly or
disassembly of the length gauge ACANTO is relevant for the correct interpretation of the status
message.
Table 2: LED states - overview

Smart Communication Module
10/24
Setting Value
WLAN - SSID scm1000
WLAN - Password 12345678
Hostname scm1000
Network IPv4 module 192.168.4.1/24
Gateway 192.168.4.1
DHCP Server active
URL opc.tcp://192.168.4.1:4840
5. INITIAL SETUP OF THE SMART COMMUNICATION MODULE
5.1 Factory Settings
The module is delivered with the following factory settings (please check table 3). For the initial
setup or a change of previous settings (for example changing the custom network name or
password), these factory defaults will be loaded and a hotspot will be generated automatically
by the SCM, in case no length gauge ACANTO is connected.
Table 3: Overview of the factory settings
5.2 Mechanical connections
The SCM-1000 has the following physical connection points:
• USB connector (Type Micro-B connector)
• 8-pin M12 coupling
Illustration4:SchematicgureoftheSCM-1000withconnectedlengthgauge
The power supply (see section 3) of the SCM-1000 and the connected length gauge is realized
via USB. Please note that SCM and connected device are using the same power supply
(Source: USB).
Illustration 5: USB connector type Micro-B
Lokales Netzwerk/WLAN
(wireless) local area network
D24
59.65
48
Questo manuale è adatto per i seguenti modelli
1
Indice
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente