Olympus BX-UCB Manuale utente

INSTRUCTIONS
BX-UCB
U-HSTR2
CONTROL BOX
HAND SWITCH
A X 9 9 4 4
This instruction manual is for the Olympus Control Box model BX-UCB and Hand Switch model U-
HSTR2, both for use with the BX2 motorized microscope. To ensure safety, optimum performance
and familiarize yourself fully with the use of the motorized microscope, we recommend that you
study this manual thoroughly before operating the system. Retain this instruction manual in an
easily accessible place near the work desk for future reference.


BX-UCB/U-HSTR2
CONTENTS
IMPORTANT — Be sure to read this section for safe use of the equipment. — 1-2
1 NOMENCLATURE
2 OPERATION
2-1 Control Box BX-UCB ..................................................................................................................................................................... 5
1Turning Power On 2Functions of Indicator LEDs
2-2 Hand Switch U-HSTR2 ............................................................................................................................................................... 5
1Attaching Indication Stickers 2Grouping Panel Sheet
2-3 Operation Settings of the DIP Switches ............................................................................................................. 6
3 SPECIFICATIONS
4 TROUBLESHOOTING GUIDE
5 ASSEMBLY - If you intend to assemble the unit by yourself, read this section first. -
PROPER SELECTION OF THE POWER SUPPLY CORD ........................................................... 11- 12
3-4
5-6
7
8
9-10

1
IMPORTANT
The BX-UCB control box is the basic module for controlling the drive of a BX2 microscope with motorized
specification. It also incorporates the power supply for the microscope.
The U-HSTR2 hand switch has a button layout optimized for the motorized BX2 system.
SAFETY PRECAUTIONS
1. Before connecting cables, be sure to set the main switch of the BX-UCB control box to “ ” (OFF)”.
2. Make sure to ground the equipment for safety and for maintaining the electrical safety performance.
3. When installing the control box, leave spaces of more than 10 cm around it. (Note that the control box also has a
ventilation air inlet on the front panel).
4. Distribute the power cord and other cables away from the lamp housing and its surroundings. Otherwise, the cord or
cable coating may melt by heat and cause an electric shock hazard.
5. Never allow the push ring driver (U-FWT/O/R) or Allen wrench that is provided with an associated module or microscope
to enter the air vents on the control box. Otherwise, an electric shock and/or malfunction may occur.
Symbol Explanation
The following symbols are found on the unit. Study the meaning of the symbols and always use the equipment in the
safest possible manner.
Before use, carefully read the instruction manual. Improper use could result in personal injury to
the user and/or damage to the equipment.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
l
Safety Symbols
Transmitted lighting.
Reflected lighting.
1Getting Ready
1. The control box and hand switch are precision equipment. Handle them carefully by avoiding any shock or impact, and
also connect each cable gently.
2. Do not use the equipment under a direct sunlight, in a place under high temperature and humidity or in a place subject
to vibrations. (For the operating environmental condition, see chapter 3, “SPECIFICATIONS” on page 7.)
3. While the main switch of the BX-UCB control box is set to “ I” (ON), do not replace any module, plug or unplug any cable
or switch the light path manually to prevent malfunction (manual switching of the revolving nosepiece is permitted).
4. Never disassemble any part of the unit as this could result in mafunctions or reduced performance.

2
BX-UCB/U-HSTR2
2Caution
If the equipment is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the
equipment may also be damaged. Always use the equipment as outlined in this instruction manual.
The following symbols are used to set off text in this instruction manual.
: Indicates that failure to follow the instructions in the warning could result in bodily harm to the
user and/or damage to equipment (including objects in the vicinity of the equipment).
# : Indicates that failure to follow the instructions could result in damage to equipment.
} : Indicates commentary (for ease of operation and maintenance).
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device complies with the requirements of directive 98/79/EC concerning in vitro diag-
nostic medical devices. CE marking means the conformity to the directive.
3Intended use
This instrument has been designed to be used to observe magnified images of specimens in routine and research
applications.
Do not use this instrument for any purpose other than its intended use.

3
NOMENCLATURE
Make sure to connect the Olympus-specified module to each connector.
The PC in use should meet the IEC60950 requirements.
If any non-specified equipment is used, Olympus cannot guarantee any performance of the system.
Control Box BX-UCB
Indicator LEDs
· RMT: Lights at the time of remote control (in orange).
· ERR: Blinks in case of an error (in red).
Lights during attachment (in green).
· NP: Lights when the specified motorized revolving
nosepiece is attached.
· MU: Lights when the BX-RFAA or BX-RLAA is attached.
· RSHT: Shutter of the BX-RFAA.
· AS: Aperture iris diaphragm of the U-UCD8A or BX-RLAA.
· FW1:
· FW2:
· FW3:
· TL : Top lens of the U-UCD8A.
· CDT: Turret of the U-UCD8A.
· Z/AF: Lights when the Z/AF board is attached.
Main switch ( I: ON, : OFF)
RS232C connector (9-pin male)
PC connector
DIP switches
Used for selection of operation
settings. (p.6)
HS (Hand Switch) connector
FW1/FW2/FW3 connectors
U-UCD8A connector
BX61/62 connector
RFAA/RLAA/NP connector
Transmitted light 100 W halogen lamp
housing connector
Reflected light 100 W halogen lamp housing
connector
Option slot
Z board or AF board can be installed.
Option slots (2 ch)
Power cord connector
} Each indicator lights when the U-FWT, FWO or
FWR is attached.

4
BX-UCB/U-HSTR2
Hand Switch U-HSTR2
}The functions of the buttons on this hand switch are variable depending on whether the attached vertical illuminator is the BX-
RFAA (on the upper stage) or the BX-RLAA (on the lower stage).
The button functions can be set arbitrarily when the PC control (remote control) is used.
}Above each button, attach the indication sticker corresponding to the function set for the button.
· TL (Top Lens) button
· DF (Darkfield) button
Grouping Panel Sheets (3 types) Indication Stickers
· RSHT (Shutter) button
· BF (Brightfield) button
AS - (Aperture iris diaphragm
close) button
AS + (Aperture iris diaphragm
open) button
Projections for blind
touch operations
Connector
Reserve button
· CDT - (Turret counterclockwise) button
· —
Objective buttons
· CDT + (Turret clockwise) button
· —
· MU + (Mirror Unit clockwise) button
· —
· MU - (Mirror Unit counterclockwise) button
· —

5
OPERATION
2-1 Control Box BX-UCB
1Turning Power On (Fig. 1)
Fig. 1
Ensure that the modules to be used are connected properly.
1. Set the main switch @ to “ I” (ON).
2. Ensure that the LED indicators ² corresponding to the connected mod-
ules are lit.
2Functions of Indicator LEDs (Fig. 1)
1. RMT: Lights only at the time of remote control.
2. ERR: Blinks in case of an error. At this time, the associated indica-
tors blink as described below.
3. NP to Z/AF: Each indicator lights when the corresponding module is
attached.
2-2 Hand Switch U-HSTR2
Fig. 2
1Attaching Indication Stickers (Fig. 2)
1. Attach each piece of the provided function indication stickers onto the
dented area @ above the button where the corresponding function is
set.
2. The indication stickers are given weak adhesive force intentionally so
that they can be removed and re-attached easily.
3. The indication stickers include two types of stickers carrying no indica-
tion on them.
· Light shield sticker: Attach to the dented area above a button with no
function set.
· Blank sticker: Create a custom indication sticker by writing the function
name with oily ink and attach to the dented area above
the required button.
Fig. 3
2Grouping Panel Sheet (Fig. 3)
Two sheets showing the function groups of buttons with enclosing lines
@ and a blank sheet ² are provided. Select and use the sheet that is
most convenient.
· Sheet @ (front): Used when a PC is not combined.
· Sheet @ (back): Used when direct designation of the mirror unit or filter
wheel is intended.
· Blank sheet ²: Can be used by drawing desired grouping lines with
oily ink pen.
@
²
@
²
@

6
BX-UCB/U-HSTR2
2-3 Operation Selection of the DIP Switches
}The allocated functions of the DIP switches are shown in the table below.
# Make sure the main switch is set to “ ” (OFF) before setting the DIP switches. The unit detects the new settings
only when the power is switched on, making those settings effective.
}The shaded sections show factory settings (all set at off).
* The freedom degree (number of available holes) search is effective only when initialization is performed at
the time of switching on the power (DIP switches 7 of SW1is set at off). The compatible motorized modules
are U-FWT, U-FWR, U-FWO and BX-RFAA.
** When using the U-D6REM or U-D5BDREM, you do not have to set the DIP switches 2 and 3 due to the revolving
nosepiece's automatic selection function.
Regarding the RS232C Cable
# Be sure to use a commercially available RS232C straight cable. (Use of other cables may cause malfunction.)
Use a D-Sub 9P (female)-D-Sub 9P (female) connector. Be sure to set the main switches of the control box and PC
to “ ” (OFF) before connecting the RS232C cable.
10
01
12345678
0
1
00
1
0
0
0
1
0
1
00000000
1
DIP Switch Bit Position (On: 1, Off: 0) Function Detail
SW1 (upper row)
Buzzer prohibited Activates buzzer.
Does not activate buzzer.
Revolving nosepiece type**
U-D5BDREMC/U-P5REMC/U-P5BDREMC
U-D6REMC/U-D6BDREMC
Not used.
Not used.
Reserved for manufacturer
Reserved for manufacturer
Fixed at off.
Fixed at off.
Freedom degree (number
of available holes) search*
Searches when power is switched on.
Does not search when power is switched on.
Initialization prohibited
when power is switched on
All fixed at off.
Reserved for manufacturer
SW2 (lower row)
Does not initialize.
Initializes.
U-D6REMC/U-D6BDREMC
U-D5BDREMC/U-P5REMC/U-P5BDREMC

7
SPECIFICATIONS
Item Specification
Control Box BX-UCB
Power supply rating Input rating: 100 to 120/220 to 240 V , 50/60 Hz, 3.5/1.5 A
LED indicators · RMT (Remote) LED · ERR (Error) LED
· Module connection LED x 10
Option slots Power capacity (single slot)
Per board Total of 3 slots
+5 V 1 A max. 2 A max.
+15 V 1 A 1 A (normal) + 1 A (motor load 20% duty)
+24 V 1 A max 2 A max.
Dimensions & weight 125(W) x 216(H) x 310(D) mm, approx. 5 kg (11 lb.)
Hand Switch U-HSTR2
Button functions Connects to the BX-UCB for use in the control of following operations.
(Can also be connected to Olympus AX70, AX80 or U-REMPS but the
operation is not normal in this case.)
When a PC is not used:
· With the BX-RFAA vertical illuminator, the hand switch controls opera-
tions including the shutter release, top lens, reserve, aperture iris dia-
phragm opening/closing, turret clockwise/counterclockwise rotation,
mirror unit clockwise/counterclockwise operation and objective switch-
ing (from 7).
· With the BX-RLAA vertical illuminator, the hand switch can control op-
erations including BF, DF, reserve, aperture iris diaphragm opening/
closing and objective switching (from 7).
When a PC is used:
· Any function can be assigned from the PC.
Dimensions & weight 147 (W) x 32 (H) x 108 (D) mm., approx. 0.37 kg (0.81 lb.)
Operating environment · Indoor use.
· Altitude: Max. 2000 m.
· Ambient temperature: 10 to 35°C.
· Maximum relative humidity: 80% (up to 31°C). The maximum humidity
decreases linearly at above 31°C, through 70% (at 34°C), 60% (at 37°C)
to 50% (at 40°C).
· Supply voltage fluctuation: ±10%.
· Pollution degree: 2 (in accordance with IEC664).
· Overvoltage category: II (in accordance with IEC664).
Altri manuali per BX-UCB
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Olympus Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente