Omicron Lab Bode 100 Manuale utente

Bode 100
Quick Start Guide

Version: ENU1006 03 02 — Year: 2019
© OMICRON Lab, OMICRON electronics. All rights reserved.
This quick start guide is a publication of OMICRON electronics.
All rights including translation reserved. Reproduction of any kind, e.g., photocopying, microfilming,
optical character recognition and/or storage in electronic data processing systems, requires the explicit
consent of OMICRON electronics. Reprinting, wholly or in part, is not permitted.
The product information, specifications, and technical data embodied in this manual represent the
technical status at the time of writing and are subject to change without prior notice.
Windows is a registered trademark of Microsoft Corporation. OMICRON Lab and Smart Measurement
Solutions are registered trademarks of OMICRON electronics.
Bode 100 Quick Start Guide
2OMICRON Lab

Contents
1 About this Quick Start Guide ......................................................................................... 4
2 Safety instructions ........................................................................................................... 5
2.1 Operator qualifications ....................................................................................................... 5
2.2 Rules for use ...................................................................................................................... 6
2.3 Designated use .................................................................................................................. 6
2.4 Disclaimer ........................................................................................................................... 6
2.5 Cleaning ............................................................................................................................. 6
3 Compliance statements and recycling .......................................................................... 7
3.1 Compliance statement ........................................................................................................ 7
3.2 Information for disposal and recycling ................................................................................ 7
4 Bode 100 and accessories ............................................................................................. 8
4.1 Delivered items ................................................................................................................... 8
4.2 Optional accessories .......................................................................................................... 9
5 Device overview .............................................................................................................. 11
6 Getting started ................................................................................................................. 12
6.1 System requirements ........................................................................................................ 12
6.2 Installing the Bode Analyzer Suite ..................................................................................... 12
6.3 Powering the Bode 100 ...................................................................................................... 12
6.4 Connecting Bode 100 to a computer ................................................................................. 13
6.5 Performing your first measurement ................................................................................... 13
7 Troubleshooting .............................................................................................................. 16
Support ............................................................................................................................. 17
Index ................................................................................................................................... 18
Contents
OMICRON Lab 3

1 About this Quick Start Guide
This Quick Start Guide was written for professional specialists in electronics and electrical
engineering. Its purpose is to familiarize you with the Bode 100 vector network analyzer and its
various application fields. It contains helpful instructions on how to use Bode 100 safely, properly, and
efficiently.
This Bode 100 Quick Start Guide provides you short information on how to install the
Bode Analyzer Suite and how to connect Bode 100 to your PC . It is intended as an aid for you to take
Bode 100 into operation quickly and easily. Thus, this Quick Start Guide only provides a small subset
of information available for Bode 100.
Therefore, we recommend to read the Bode 100 User Manual, which is available in PDF format on the
DVD delivered with Bode 100.
Furthermore, the Bode 100 User Manual can be viewed by clicking the icon at the top right corner
of the Bode Analyzer Suite screen.
In addition, the latest version of this Quick Start Guide and the Bode 100 User Manual can be
downloaded from www.omicron-lab.com.
Safety symbols used in this document
DANGER
Death or severe injury will occur if the appropriate safety instructions are not
observed.
WARNING
Death or severe injury can occur if the appropriate safety instructions are not
observed.
CAUTION
Minor or moderate injury may occur if the appropriate safety instructions are not
observed.
NOTICE
Equipment damage or loss of data possible
Bode 100 Quick Start Guide
4OMICRON Lab

2 Safety instructions
Before operating Bode 100 and its accessories, read the following safety instructions carefully. If you
do not understand some safety instructions, contact OMICRON Lab before proceeding. When working
with Bode 100, observe all safety instructions in this document. You are responsible for every
application that makes use of an OMICRON or OMICRON Lab product. Any miss-operation can result
in damage to property or persons. Maintenance and repair of Bode 100 and its accessories is only
permitted by qualified experts either at OMICRON Lab or at certified repair centers.
Following these instructions will help you to prevent danger, repair costs and possible down time due
to incorrect operation. Furthermore, it ensures the reliability and life-cycle of Bode 100.
Use Bode 100 in observance of all existing safety requirements from national standards for
accident prevention and environmental protection.
Reading the Bode 100 manual alone does not release you from the duty of complying with all national
and international safety regulations relevant for working with Bode 100, for example, the regulation
EN50191 "Erection and Operation of Electrical Test Equipment”.
WARNING
Bode 100 is a SELV device (SELV = Safety Extra Low Voltage according to IEC
60950).
► Do not apply hazardous voltage levels >50 VDC or >25 VAC to the inputs of
Bode 100.
► Ensure that voltage and current probes used with Bode 100 are properly grounded
in accordance with their manufacturer's guidelines.
► When working with voltage or current probes, always connect the Bode 100's
ground terminal (available for HW Rev. 2 or higher) with a solid connection of at
least 3.6 mm² cross-section and not longer than 10 m to the ground terminal in the
laboratory.
► Be aware that no indication on Bode 100 shows that the output is active. This
could be especially critical if amplifiers are connected to Bode 100.
2.1 Operator qualifications
• Testing with Bode 100 must only be carried out by qualified, skilled and authorized personnel.
• Personnel receiving training, instructions, directions, or education on Bode 100 must be under
constant supervision of an experienced operator while working with the equipment.
• Testing with Bode 100 must comply with the internal safety instructions as well as additional
relevant documents.
Safety instructions
OMICRON Lab 5

2.2 Rules for use
•Bode 100 is exclusively intended for the application area specified in this document. The
manufacturer/distributors are not liable for damage resulting from a use other than the specified
operation. The user alone assumes all responsibility and risk.
• Use Bode 100 only when it is in a technically sound condition.
• Do not open Bode 100 or remove any of its housing components.
• Do not carry out any modifications, extensions or adaptations to Bode 100.
• Use Bode 100 in observance of all existing safety requirements from national and international
standards for accident prevention and environmental protection.
• Always keep the manual either printed or as PDF file at the site where Bode 100 is used. The
manual must be read by all people working with Bode 100. In addition to the manual and the
applicable regulations for accident prevention in the country and at the site of operation, heed the
accepted technical procedures for safe and competent work.
2.3 Designated use
Bode 100 and its accessories are especially designed for swept frequency measurements of
electronic circuits in laboratory and manufacturing environments.
Examples for typical applications are:
• Measurement of the complex transfer function of amplifiers, filters and attenuators
• S-Parameter measurement in the 50 Ohm domain
• Stability assessment of control loops
• Determination of resonance frequencies of piezo elements and quartz crystals
• Impedance measurement of inductors, capacitors and resistors
2.4 Disclaimer
The advisory procedures and information contained within this document have been compiled as a
guide to the safe and effective operation of Bode 100. It has been prepared in conjunction with
application engineers and the collective experience of the manufacturer.
The in-service conditions for the use of Bode 100 may vary between customers and end-users.
Consequently, this document is offered as a guide only. It shall be used in conjunction with the
customers own safety procedures, maintenance program, engineering judgment, and training
qualifications.
Using Bode 100 or its accessories in a manner not specified by the manufacturer may result in
damage to property or persons.
2.5 Cleaning
Use a cloth dampened with isopropanol alcohol to clean Bode 100 and its accessories.
Bode 100 Quick Start Guide
6OMICRON Lab

3 Compliance statements and recycling
3.1 Compliance statement
Declaration of Conformity (EU)
The equipment adheres to the guidelines of the council of the European Community for meeting the
requirements of the member states regarding the electromagnetic compatibility (EMC) directive and
the RoHS directive.
FCC compliance (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case
the user will be required to correct the interference at his own expense. Changes or modifications not
expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
Declaration of compliance (Canada)
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe
A est conforme à la norme NMB-003 du Canada.
3.2 Information for disposal and recycling
Bode 100 and all of its accessories are not intended for household use. At
the end of its service life, do not dispose of the test set with household
waste!
For customers in EU countries (incl. European Economic Area)
OMICRON test sets are subject to the EU Waste Electrical and Electronic
Equipment Directive (WEEE directive). As part of our legal obligations
under this legislation, OMICRON offers to take back the test set and to
ensure that it is disposed of by an authorized recycling facility.
For customers outside the European Economic Area
Please contact the authorities in charge for the relevant environmental
regulations in your country and dispose Bode 100 and all of its
accessories only in accordance with your local legal requirements.
Compliance statements and recycling
OMICRON Lab 7

4 Bode 100 and accessories
4.1 Delivered items
Bode 100
multi functional test set Bode Analyzer Suite on DVD Wide-range AC power supply
including mains input plugs for
different national standards
Test objects
(Quartz filter and IF filter) on
PCB
USB Cable
4 pc. BNC 50 Ω cables with 500
mm length (m-m)
BNC adapters (straight, T, Short,
Load 50 Ω) Bode 100 Quick Start Guide Multilingual safety instructions
The delivered items may vary a bit from the look shown above. Please refer to the packing
list received with the Bode 100 for further information
Bode 100 Quick Start Guide
8OMICRON Lab

4.2 Optional accessories
B-WIT 100 Wideband Injection Transformer
The B-WIT 100 is used to inject signals into control loops. Its main
application is in the stability analysis of switched mode power
supplies and linear voltage regulators.
Order number: OL000151
B-LFT 100 Low-Frequency Injection Transformer
The B-LFT 100 is especially designed to inject low frequencies into
control loops such as PFC voltage loops.
Order number: OL000169
PML-111O 10:1 Passive Probe
PML-111O is a passive 10:1 probe designed for the input stage of
Bode 100. It is manufactured by PMK in Germany and fits perfectly
to the Bode 100.
Order number: OL000110
B-SMC Impedance Adapter for surface mount components
The B-SMC extends the impedance measurement range of
Bode 100. It enables you to easily measure components for
surface mounting such as ceramic capacitors or chip resistors.
Order number: OL000152
B-WIC Impedance Adapter for thru hole type components
The B-WIC extends the impedance measurement range of
Bode 100. It enables you to perform impedance measurements for
thru hole type components such as inductors or crystal oscillators.
Order number: OL000153
B-AMP 12 Amplifier
12 dB amplifier to boost the output signal of Bode 100 for
applications where more than 13 dBm are needed.
Order number: OL000168
B-LCM Common Mode Choke
A low-frequency common mode choke to reduce ground-loop
errors in e.g. Shunt-Thru measurements.
Order number: OL000175
Bode 100 and accessories
OMICRON Lab 9

B-RFID Measurement Adapters
The B-RFID adapters allow standard compliant measurement of
the resonance frequency and Q-factor of RFID antennas.
Order numbers: OL000170-OL000173
For more information on the above mentioned Bode 100 accessories and recommended
accessories manufactured by partner companies visit www.omicron-lab.com.
Bode 100 Quick Start Guide
10 OMICRON Lab
Altri manuali per Bode 100
3
Indice
Altri manuali Omicron Lab Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione













