One-Tool B70 Manuale utente

Battery Tester B70
1
BATTERY ANALYZER B70
Graphic Instructions
How To Operate
3-1. Battery Test
3-2. Alternator Test
3-3. Crank Motor Test
Battery Spec Charts
This machine is for 12V & 24V Lead-Acid vehicle battery.
Please don’t store the machine in high temp or humidity place. It’ll
damage the machine.
The working voltage range is 9V~35V DC.
Please operate after turn on the headlight 3~5 minutes to clean the
surface voltage when the battery was just full recharged.
The bad connect cable between 2pcs of 12V battery (24V system) will
cause the wrong result. Please check individual battery to ensure.
2. Graphic Instruction
1. Monitor Zone: Show Functions & Information
2. Function Zone: Input Data & Select Functions
1. Select: Press Up/Down/Left/Right to input data or select function.

Battery Tester B70
2
2. Enter: Confirm the selected function or data.
3. Exit: Abort the function or clear the data.
3. How to Operate.
3.1 Battery Test----12/24V
Select Test Item--Battery
Select Battery Type
Enter Battery Rating
Select Input ▲▼
CCA IEC
EN JIS
DIN Unknown
Select Rating ▲▼
SET 520 CCA
Press Enter to Start
Analyzing Wait
▌▌
Select Item ▲▼
Battery
Alternator
Cranking

Battery Tester B70
3
Waiting for Result
Result
Battery Voltage 12.52V
Charged 100% 13.2V
90% 12.9V
75% 12.45V
CCA Value 480CCA
The computed CCA value
In 24V system testing, CCA is the half of the sum of two batteries.
Internal Resist 6.65mΩ
(Int.R) It will between 2-15mΩ
Greater CCA with minor resist
In 24V system testing, Internal Resist will the sum of two batteries.
LIFE The computed life of battery, suggest to change if under 50%
RESULTS Good
12.52V 480 CCA
Int.R 6.65mΩ
LIFE 65%
RESULTS Good
25.86V 80CCA
Int.R. 13.30mΩ
LIFE 65%

Battery Tester B70
4
3.2 Alternator Test----12V
Select Testing Item—Alternator
Start the engine then press Enter to test
Pump to 3000 RPM for 3-5 Seconds,
Max Volt must under 15.0V, Min V must above 13.3V
(When turn off all loads)
Select Item ▲▼
Battery
Alternator
Cranking
Start the Engine
Then press Enter
3000RPM 13.96V
Max 14.07 V < 15.0 V
Min 13.55 V > 13.3 V
Press Enter Continue
Load is all opened
Then press Enter

Battery Tester B70
5
2000RPM 13.89V
Max13.96 V > 13.5V
Min 13.76V > 12.5V
Turn on the headlight & A/C(Max),
Then press Enter to start
Pump to 2000 RPM for 3-5 Seconds,
Max Volt must above 13.5V, Min V must above 12.5V (When turn on all loads)
3.3 Alternator Test----24V
Select Testing Item—Alternator
Start the engine then press Enter to test
Select Item ▲▼
Battery
Alternator
Cranking
Start the Engine
Then press Enter

Battery Tester B70
6
1500RPM 28.89V
Max28.96 V > 27.0V
Min 27.76V > 25.0V
Pump to 1000 RPM for 2-5 Seconds,
Max Volt must under 30.0V, Min V must above 26.6V (When turn off all loads)
Turn on the headlight & A/C(Max),
Then press Enter to start
Pump to 1500 RPM for 2-5 Seconds,
Max Volt must above 27.0V, Min V must above 25.0V (When full loading)
3.4 Crank Motor Test----12V
1000RPM 27.96V
Max 38.57 V < 30.0 V
Min 26.55 V > 26.6 V
Press Enter Continue
Load is all opened
Then press Enter

Battery Tester B70
7
Select Test Item—Cranking
The voltage should be above 9.2V when cranking.
Please test the battery before testing the alternator and crank motor. The bad
battery will affect the result of alternator and crank motor testing.
We should test the crank motor particularly when the voltage is under 9.2V,
but the result of battery testing is good.
Please change a good battery then start this test if the battery marked as
REPLACE in the battery testing.
3.5 Crank Motor Test----24V
Select Item ▲▼
Battery
Alternator
Cranking
Start the motor
Normal V 12.6 V
Crank V 10.3 V
Crank V > 9.2 V
Select Item ▲▼
Battery
Alternator
Cranking

Battery Tester B70
8
Select Test Item—Cranking
The voltage should be above 16.0V when cranking.
Please test the battery before testing the alternator and crank motor. The bad
battery will affect the result of alternator and crank motor testing.
We should test the crank motor particularly when the voltage is under 9.2V,
but the result of battery testing is good.
Please change a good battery then start this test if the battery marked as
REPLACE in the battery testing.
Where The Battery Model Number Is.
Start the motor
Normal V 25.90 V
Crank V 17.81 V
Crank V > 16.0 V

Battery Tester B70
9
Traditional test method (1/2 CCA Load Test)
A deep discharge test simulating the demands imposed on a battery. Test the
ability to deliver a starter motor's cranking current requirements while
maintaining a terminal post voltage above a minimum standard.
Apply a load equal to 1/2 the CCA rating for 15 seconds and measure the
voltage drop. Compare the voltage to a voltage chart.
The battery state -of-charge must be 75% (12.4 v) to perform a 1/2 CCA test. If
the battery is below 75% state-of-charge, it must be charged before testing.
New Measurement Techniques:
Ohmic Measurement
Resistance Measurements(DC method)
Impedance Measurements(AC method)
Conductance Measurements(AC method)
Resistance Measurement
Resistance measurements can be performed by applying a load across the
cell/unit and measuring the step change in voltage and current. The Ohmic
value is calculated by dividing the change in voltage by the change in current.

Battery Tester B70
10
Impedance Measurements
Impedance measurements can be performed by passing a current of known
frequency and amplitude through the battery and measuring the resultant ac
voltage drop across each cell/unit. The ac voltage measurement is taken
between the positive and negative terminals of individual cells or the smallest
group of cells possible. Compute the resultant impedance by Ohm's law.
Conductance measurements(Our Testing Method)
Conductance measurements can be performed by applying a voltage of known
frequency and amplitude across a cell/unit and observing the ac current that
flows in response to it. The conductance is the ratio of the ac current
component that is in-phase with the ac voltage, to the amplitude of the ac
voltage producing it.
The Benefit of Our Test Method
Conductance correlates directly to battery capacity
Passive test method is safe & repeatable
Never discharges the battery
Can Test discharged batteries
Provides a unique indication of battery
Indice
Altri manuali One-Tool Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione