Oxygen X-Air C200 Manuale utente

Rev 2.3 2021.04
INSTALLATION AND OPERATION MANUAL
Heat Recovery Unit
OXYGEN X-Air C200

1

2
TABLE OF CONTENTS
1. TRANSPORTATION AND STORAGE OF EQUIPEMENT ................................................................................................. 3
2. UNIT PACKAGE ........................................................................................................................................................... 4
3. SAFETY REQUIREMENTS ............................................................................................................................................. 5
4. EU DECLARATION OF CONFORMITY........................................................................................................................... 6
5. TECHNICAL DATA ....................................................................................................................................................... 7
5.1. Product information sheet. Delegated Regulation (EU) 1254/2014 ............................................................. 7
5.2. Performance curves ...................................................................................................................................... 8
5.3. Performance and power consumption ......................................................................................................... 8
5.4. Sound characteristics .................................................................................................................................... 9
5.5. Dimensions and weight ............................................................................................................................... 10
6. FUNCTIONALITY ....................................................................................................................................................... 11
7. INSTALLATION OF THE UNIT .................................................................................................................................... 12
7.1. Selecting the mounting location ................................................................................................................. 12
7.2. Installation incline ....................................................................................................................................... 12
7.3. Connecting ducts ........................................................................................................................................ 13
7.4. Installing the maintenance and service hatch ............................................................................................ 14
7.5. Connecting the condensate drain ............................................................................................................... 15
7.6. Ventilation system balancing ...................................................................................................................... 16
8. CONNECTION OF THE UNIT ...................................................................................................................................... 17
8.1. Connecting electric circuit .......................................................................................................................... 17
8.2. Installation of the control panel ................................................................................................................. 18
8.3. Connector of comfort functions ................................................................................................................. 19
8.4. Control board electrical wiring diagram ..................................................................................................... 20
8.5. Description of control board contacts ........................................................................................................ 21
9. OPERATION OF THE UNIT ......................................................................................................................................... 22
9.1. WiFi controller ............................................................................................................................................ 22
9.1.1. Downloading the app ............................................................................................................................. 22
9.1.2. WiFi connection set-up ........................................................................................................................... 23
9.1.3. App home screen .................................................................................................................................... 25
9.1.4. Setting up weekly operation program .................................................................................................... 25
9.1.5. Ventilation boost activation ................................................................................................................... 26
9.1.6. Away ....................................................................................................................................................... 26
9.1.7. Filter menu ............................................................................................................................................. 27
9.1.8. Resetting WiFi controller to factory defaults ......................................................................................... 27
9.2. Control panel with touchscreen display ..................................................................................................... 28
9.2.1. Standby mode......................................................................................................................................... 28
9.2.2. Main screen ............................................................................................................................................ 29
9.2.3. Settings menu ......................................................................................................................................... 30
9.2.4. Setting up weekly operation program .................................................................................................... 31
9.2.5. Failure indication .................................................................................................................................... 31
9.3. Control panel with a knob ........................................................................................................................... 32
9.3.1. Operating state indicator ....................................................................................................................... 32
9.3.2. Air filter replacing / anti-frost protection indicator ............................................................................... 33
9.3.3. Failure indicator ...................................................................................................................................... 33
9.3.4. RESET procedure .................................................................................................................................... 34
9.3.5. Resetting the filter lifetime meter .......................................................................................................... 34
9.3.6. Additional system settings ..................................................................................................................... 35
9.4. Replacing air filters ..................................................................................................................................... 36
10. MAINTEINANCE AND WARRANTY ............................................................................................................................ 38
11. CONTACTS ................................................................................................................................................................ 39

3
1. TRANSPORTATION AND STORAGE OF EQUIPEMENT
Heat Recovery Unit (hereinafter – the Unit) is prepared for transportation and storage. Packaging
materials ensure protection against exposure to environment, dust and humidity. The Unit must be
properly secured during transportation to protect it against possible housing deformation or other
mechanical damage.
Transportation conditions:
-20oC - +40oC.
Long-term storage conditions:
+5oC - +40oC, relative air humidity <= 50%.
CONSIGNMENT ACCEPTANCE:
Carefully check the received consignment – make sure that the number of packages matches
with the consignment documentation. Upon noticing any non-conformity or damage of the
package (tears, dents or compressed box, detached or reattached packaging tape), inform the
courier immediately and indicate the disrepancies or damages in the consignment document.
Verify if the right product was delivered. Upon noticing any non-conformity, inform the Sender
immediately.
Verify if all the supplementary parts listed were delivered. In case of any doubt, contact the
Sender immediately.
Do not attempt to repair the Unit, damaged during the transportation by yourself!
IMPORTANT! Sender does not assume any obligations towards damage or loss of the Unit or its part,
if there is no a corresponding record in the consignment document!

4
2. UNIT PACKAGE
Heat Recovery Unit OXYGEN X-Air C200 1 pc
Control panel (10m connection cable included) or WiFi adapter 1 pc
Fastening elements:
L-shaped horizontal installation bracket 4 pcs
Bolt (type M5), 8 mm 8 pcs
Spring washer (type M5) 8 pcs
Condensate drain nozzle, Ø32 1 pc
Condensate drain gasket, Ø20 1 pc
Installation manual 1 pc

5
3. SAFETY REQUIREMENTS
Carefully read and follow safety requirements provided below before installing and while operating
the Unit:
Do not discard the Installation and operation manual, keep it for future reference.
The Unit should be installed and operated in compliance with this Installation and operation
manual, following the requirements of effective legislation and standards.
When connecting the Unit to mains supply, grounding must be installed in compliance with
requirements of effective legislation and standards.
To prevent accidents and potential damage to the Unit it should be installed, connected,
maintained and repaired only by qualified technician. Never attempt to do this by yourself!
Turn off the Unit by using Control panel and wait for fans to stop completely before replacing
air filters.
Turn off the Unit by using Control panel, wait for fans to stop completely and disconnect the
Unit from mains supply before performing any maintenance.
Disconnect the Unit from mains supply before disconnecting or reconnecting the control
panel.
Before connecting the Unit make sure that no items will get sucked into the its air intake
openings!
The Unit is not intended to be used by persons (including children) with reduced physical,
sensory or mental capabilities, unless they have been instructed to use the Unit and under
constant supervision of person held responsible for their safety.
Children may only use the Unit under adult supervision.
Only original supplementary parts and consumables, certified by manufacturer should be
used.
The Unit package (cardboard, plastic, foam polystyrene) can pose hazard to children. Dispose
or recycle the package elements!
Disused Unit should be disposed in accordance with requirements of legislation on handling
of waste electrical and electronic equipment.
IT IS PROHIBITED to operate the Unit with damaged mains supply cable! Switch off the power
circuit-breaker to disconnect mains supply and contact a qualified technician or manufacturer
service centre immediately upon noticing such damage.
IT IS PROHIBITED to attempt the repair of the damaged Unit or its part, to open its
maintenance and service hatch! Contact a qualified technician or manufacturer service centre.
IT IS PROHIBITED to operate the Unit while construction works are still in progress to remove
dust or excess moisture. Fine dust of building materials, used in construction, can irreversibly
change characteristics of the heat exchanger or cause damage to sensitive electronic
components. Failure of the Unit caused by such operation will void the warranty.

6
4. EU DECLARATION OF CONFORMITY
We, undersigned below, representing the manufacturer of ventilation equipment:
Sviezias oras, JSC
Birzelio 23-osios g. 23G
50220 Kaunas
LITHUANIA
confirm, that heat recovery ventilation device OXYGEN X-Air C200 conforms to Europe Union
standarts, directives and regulations:
2009/125/EC – eco-design requirements for energy-related products
ES 1253/2014
ES 1254/2014
ES 2017/1369
EN 13141-7:2010
2010/30/EU – labelling and standard product information of the consumption of energy and other
resources by energy-related products
ES 1254/2014
2011/65/EU – restriction of the use of certain hazardous substances in electrical and electronic
equipment (RoHS)
EN 50581(2012)
2014/35/EU – harmonization of the laws of the Member States relating to the making available on
the market of electrical equipment designed for use within certain voltage limits
EN 60335-1:2012
EN 60335-1:2012/A11:2014
CEO Zilvinas Salialionis
17.11.2020, Kaunas

7
5. TECHNICAL DATA
5.1. Product information sheet. Delegated Regulation (EU) 1254/2014
a) Supplier's name or trade mark OXYGEN
b) Model identifier X-Air C200
c) Specific energy consumption (SEC), SEC class A
Cold climate kWh/m2.a -83.8
Average climate kWh/m2.a -40.7
Warm climate kWh/m2.a -16.0
d) Declared typology Bi-directional,
residential ventilation
e) Type of drive installed or intended to be Variable speed drive
f) Type of heat recovery system Recuperative
g) Thermal efficiency of heat recovery % 81
h) Maximum flow rate m3/h 191
i) Electric power input of the fan drive, including W 106
j) Sound power level (LWA) 49
k) Reference flow rate m3/s 0.039
l) Reference pressure difference Pa 50
m) Specific power input (SPI) W/(m3/h) 0.33
n) Control factor 0.65
Control typology Local demand control
o) Declared maximum leakage rate:
internal % 2.2
external % 1.2
q) Position and description of visual filter warning Refer to installation
and operation manual
s) Internet address for pre-/dis-assembly www.oxygenvent.com
v) The annual electricity consumption (AEC) kWh/m2.a
1.7
w) The annual heating saved (AHS)
Cold climate kWh/a 88.2
Average climate kWh/a 45.1
Warm climate kWh/a 20.4

8
5.2. Performance curves
Graph. 1. Ventilation power dependence on the resistance of installed ventilation system
5.3. Performance and power consumption
Power setting Resistance, Pa Air flow, m3/h El. consumption, W
100%
100 191 96
150 177 94
200 154 93
250 130 90
300 106 88
350 81 84
400 54 80
450 16 79
70%
50 136 44
75 122 44
100 108 43
125 92 42
150 77 40
175 60 39
200 46 38
225 16 38
50% 25 100 24
75 80 24
Measured according to EN13141-7 with G4 class filters installed.
0
50
100
150
200
250
300
350
400
450
500
0 50 100 150 200
Resistance, Pa
Air flow, m3/h
Performance curves
70%
100%
50%

9
5.4. Sound characteristics
Power
setting Air duct
Sound power level (LWA)
Octave band, Hz Total
125 250 500 1000 2000 4000 8000
50%
Suppply 34.1 42.8 42.2 41.7 40.9 30.6 17.5 48.2
Extract 13.3 35.6 35 26.8 22.4 14.8 12.6 38.8
Outside 15.1 36.7 32.1 26.9 21.8 14.4 12.6 38.5
Exhaust 28.9 39.7 42 40.7 38.5 28.6 16 46.6
70%
Suppply 39 51.1 51.8 51.2 49.9 43.8 30.4 57.3
Extract 21.5 45.2 44.5 36.6 33.2 22.5 14.2 48.4
Outside 22 44.6 42.8 36.1 33.1 21.7 13.7 47.3
Exhaust 35.4 51.1 51.6 50.4 48.4 41.8 28.7 56.8
100%
Suppply 43 56.1 63.3 58.5 58.7 53.6 41.3 66.3
Extract 30.1 47.7 55.3 46.5 42.4 32.1 21.6 56.7
Outside 29.7 48.1 54.3 45.7 42.4 30.7 20.7 55.9
Exhaust 41.2 53.3 62 58.4 57.6 52.7 40 65.2
Measured according to LST EN13141-7.
Altri manuali per X-Air C200
1
Indice
Altri manuali Oxygen Sistema di riscaldamento

Oxygen
Oxygen X-Air V500E Manuale utente

Oxygen
Oxygen X-Air V200 Manuale utente

Oxygen
Oxygen X-Air C180E Manuale utente

Oxygen
Oxygen X-Air V400 Manuale utente

Oxygen
Oxygen X-Air C180 Manuale utente

Oxygen
Oxygen X-Air V600 Manuale utente

Oxygen
Oxygen X-Air C250 Manuale utente

Oxygen
Oxygen X-Air V400E Manuale utente

Oxygen
Oxygen TYPHON 2000 Manuale utente

Oxygen
Oxygen X-Air C200E Manuale utente