LC120
MODE
cm³/Impulse
IMPULSE
LC120
MODE
Month
TIME
SET
MODE
◄
TIME
3
4
1
2
1 + V DC
2 OK
3 GND
4 Err
210 0 1
40101
OK/ Err Err LC 2101
40 0 1
OK/ Err Err/LC
LC60
LC120
LC250
LC500
MODE
TIME
TIME Mode
Electrical connection Signal output Connection in parallel
IMPULSE Mode
https://www.permausa.com/en/downloads/quick-start-guides/
HINT
Wiring diagram for 4 perma STAR CONTROL
OR
4. Confi guration
5. Electrical connection
6. Quick Reference
Feature Description
Power supply Power supply is indicated by the plug symbol in the display.
Purge
Access the purge feature by holding down the SET button for 10 seconds. Release
the button when “PU” appears and the purge will start automatically and show the
“PU” LCD display. The green LED will fl ash. The purge cycle runs for 3 complete
discharges of the drive spindle to deliver around 6 cc of grease. It can be stopped
at any time by pushing the SET button once.
Normal operation:
- Green LEDs fl ash every 7 seconds
- LCD screen displays TIME / IMPULSE setting & volume
Run cycle (lubricant being delivered):
- Green LED’s fl ash every second
- LCD screen displays “ru”
Empty Lubricant Cartridge (LC):
- Red LED’s double fl ash every 2 seconds
- LCD screen displays “LC”
Blockage / Back Pressure Overload (OL):
- Red LED’s double fl ash every 7 seconds
- LCD screen displays “OL”
Purge (PU):
- Green LED’s fl ash every second
- LCD screen displays “PU”
C120
◄
cm³
C120
cm³
LED Light & LCD
Screen combinations
9-30 V OUTPUT
Set the LC size by
pressing the SET button
(60, 120, 250, 500 cc)
Hold down SET button for 5 s; Select
desired mode (“TIME” & “IMPULSE”)
by pressing the SET button
Set the discharge period
(1-12 months; 1-26 weeks → only 500 cc)
Cycle through discharge setting with the
SET button
Set the discharge volume
(0,1 - 9,5 cc)
Cycle through volume setting with the
SET button