GENERAL SAFETY INSTRUCTIONS
1. Read Instructions - All safety and operation instructions must be read.
2. Retain Instructions - The safety and operating instructions should be kept for future
reference.
3. Heed Warnings - All warnings should be followed.
4. Follow Instructions - All installation and operating instructions should be followed.
5. Water – The QuietCool system should not be used near water. If you live in a very humid
climate, be sure to cover your damper box with insulation to reduce condensation.
6. Heat - The QuietCool system should be situated away from heat sources.
7. Damage Requiring Service - Only qualified service personnel should service the
QuietCool system. The user should not attempt to service the product.
CONTENTS
1. SYSTEM OVERVIEW......................................................3
1-1 Introduction.......................................................3
1-2 Features ..........................................................3
1-3 Key Specifications .................................................3
2. INSTALLATION ..........................................................4
2-1 Installing the Hub .................................................4
2-2 Wiring the Hub.....................................................4
2-3 Fan Hub LED Indicators ...........................................10
2-4 Pairing the Wall Switch............................................ 11
2-5 Finding a Location for the Wall Switch ............................. 11
2-6 Installing the Wall Switch .........................................12
3. OPERATION ............................................................12
3-1 Operating the Wall Switch .........................................12
3-2 Frequently Asked Questions.......................................13
RF WIRELESS CONTROL WARRANTY ...................................15
ADVANCED WHOLE HOUSE FANS
®
QC Manufacturing, Inc.
43352 Business Park Drive
Temecula, CA 92590
PH 951.325.6340
FX 951.325.6351
QuietCoolSystems.com
INCLUDED IN THE BOX
- IT-RFHUB-01 RF Control Hub - IT-RFSWITCH-01 RF Switch - QuietCool Owner’s Guide
- (2) AAA batteries - Mounting screws and drywall anchors

1-888-QUIETCOOL
3
STOP! READ ALL INSTRUCTIONS IN THIS GUIDE BEFORE INSTALLING YOUR
QUIETCOOL SYSTEM
Read this guide before proceeding! The manufacturer is NOT responsible for faulty
installation or product damages caused through failure to fully read this guide BEFORE
attempting installation.
FCC Regulations
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution
Changes or modifications not expressly approved by the part responsible for compliance could void the user's
authority to operate the equipment.
1. SYSTEM OVERVIEW
1-1 INTRODUCTION
Congratulations on the purchase of your new QuietCool RF Wireless Control!
The QuietCool Whole House Fan RF Wireless Control is the simplest way to control your
QuietCool Advanced Whole House Fan from anywhere in your home!
The QuietCool RF Wireless Control allows users to set the length of time that the fan will run
and set the desired speed level.
1-2 Features
• Control your QuietCool from anywhere in your home
• Set countdown time for each QuietCool in your home (up to 12 hours)
• Adjust speed setting for each multi-speed QuietCool
• Pair up to 20 switches to each Hub
• Surface mount wall switch that can be removed and used from anywhere in the home
1-3 Key Specifications
IT-RFHUB-01 (Hub):
Voltage: 120V
Frequency: 60Hz
Motor load: 1HP, 735W (Max)
IT-RFSWITCH-01 (Switch):
Voltage: 3VDC (2 AAA batteries)
Battery Standby Current: ≤10uA
RF working distance: 100ft (no obstructions)

QUIETCOOLSYSTEMS.COM
4
2. INSTALLATION
2-1 Installing the Hub
IMPORTANT: If you are installing the Hub onto an existing QuietCool fan, be sure
to shut off the power before attempting installation. If you are installing the Hub
onto a new fan, perform all installation steps before plugging in the fan.
Install the Hub directly to the motorhead:
1. Remove the handy box cover on your QuietCool fan. Remove the wire nuts from the power
cord and motor wires inside the handy box. Remove the ground screw.
2. Remove the power cord bushing and power cord. Keep both the bushing and power cord as
you will be using it for the installation of the hub.
3. Remove the four screws that are used to mount the handy box to the QuietCool motorhead.
Retain the four screws as you will be using them to attach the Hub to the QuietCool
motorhead.
4. Using your philips screwdriver, open up the Hub and install the powercord bushing through
the hole at the back of the hub.
5. Run the motor wire leads through the large knockout in the bottom of the hub.
6. Using the four screws from the handybox, mount the Hub to your QuietCool motorhead.
2-2 Wiring the Hub
NOTE: Wiring Diagrams are for examples only and wiring should be done
by an experienced electrician. 12 or 14-gauge romex is common. Check your
local building code before choosing the wire type.
NOTE: Ensure the power is disconnected before performing any wiring
connections.
NOTE: The wiring diagrams and instructions are shown using the power cord
included with your QuietCool. The installation can also be performed with
2-wire romex and hard wired.
NOTE: If you are retrofitting the RF Control, you will have to un-wire the existing
wall swtich. You will reuse the power that was run to the switch to go directly into
the RF Control Hub.
TOOLS YOU WILL NEED
- Phillips screwdriver - Power-drill - Philips bit

1-888-QUIETCOOL
5
Single Speed Wiring (for all 1500/1.5 models) (see Figure A)
1. Using a wire nut, connect the black wire from the power cord to the black wire
from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub
4. Cap the yellow and red wires from the Hub.
5. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
6. Set the dip switch positions inside the Hub as shown in the diagram below.
7. Power-on the Hub. The Power LED indicator will be lit.
8. Press the Test button to make sure the fan works. The Test LED indicator will
blink once every two seconds indicating 1-speed and the fan will be on. Press
the Test button again and the fan should shut off and the LED will be off.
9. If the fan doesn’t operate as described in step 8, please check the dip switch
postion.
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - ON
2 - OFF
3 - OFF
ON
1 2 3
Whole House Fan
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - ON
2 - OFF
3 - OFF
ON
1 2 3
Whole House Fan
Figure A

QUIETCOOLSYSTEMS.COM
6
Two Speed Wiring (for CL-2250 to 7000 and TRI PRO-2.5 to 7.0) (see Figure B)
1. Using a wire nut, connect the black wire from the power cord to the black wire
from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub
4. Connect the red wire from the fan to the red wire on the Hub
5. Cap the yellow wire from the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram below.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will
blink twice every two seconds indicating 2-speed and the fan will be on high.
Press the Test button again and the fan will switch to low speed. Press the Test
button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch
postion.
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Whole House Fan
ON
1 2 3
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Whole House Fan
ON
1 2 3
Figure B

1-888-QUIETCOOL
7
Two Speed Wiring (for ES-2250 and STL PRO-2.5) (see Figure C)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub
4. Connect the yellow wire from the fan to the blue wire on the Hub
5. Cap the yellow wire from the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram below.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will
blink twice every two seconds indicating 2-speed and the fan will be on high.
Press the Test button again and the fan will switch to low speed. Press the Test
button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch
postion.
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure C

QUIETCOOLSYSTEMS.COM
8
Two Speed Wiring (for ES-3100, 4700, 5400, 6000, 7000, and STL PRO-3.3)
(see Figure D)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub
4. Connect the blue wire from the fan to the blue wire on the Hub
5. Cap the yellow wire from the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram below.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will
blink twice every two seconds indicating 2-speed and the fan will be on high.
Press the Test button again and the fan will switch to low speed. Press the Test
button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch
postion.
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure D

1-888-QUIETCOOL
9
Three Speed Wiring (for STL PRO-4.8, 5.5, 6.0, & 7.0) (see Figure E)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub
4. Connect the yellow wire from the fan to the yellow wire on the Hub
5. Connect the blue wire from the fan to the blue wire on the Hub
6. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram below.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will
blink three times every two seconds indicating 3-speed and the fan will be on
high. Press the Test button again and the fan will switch to medium speed.
Press the Test button again and the fan will switch to low speed. Press the Test
button again and the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch
postion.
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - OFF
3 - ON
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - OFF
3 - ON
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure E

QUIETCOOLSYSTEMS.COM
10
2-3 Fan Hub LED Indicators
Power Indicator
• The Power LED indicator will
always be lit when the Hub is
connected to Power.
• If this LED is not lit, check the
power source
Timer Indicator
• The Timer LED indicator will light
up as shown below:
1. 1 Hour: 1 Blink
2. 2 Hours: 2 Blinks
3. 4 Hours: 4 Blinks
4. 8 Hours: 8 Blinks
5. 12 Hours: 12 Blinks
6. Continuous On: Off
Test Indicator
• The Test LED indicator will light up as shown below when the Test button is pressed and
when the fan is turned on via the Wall Switch:
1. One Speed Fan: blink once every 2 seconds
2. Two Speed Fan: blink twice every 2 seconds
3. Three Speed Fan: blink three times every 2 seconds
Pair Indicator
• The Pair LED indicator will light up when making pair operations. Please see page 12 for
details on pairing.
Notes on Operation
• If the Dip Switch is not configured correctly, all the indicators on the Hub will stay solid
when the Hub is powered on. Please switch off power and re-configure the Dip Switch as
shown in the wiring diagrams.
POWER TIMER PAIRTEST
Indice
Altri manuali QuietCool Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente