1. GUIDELINES, STANDARDS AND CONDITIONS
1.1 Applicable guidelines and standards 3
1.2 Approved personnel 3
1.3 Warning about discouraged use 3
1.4 Warranty provisions 3
2. SAFETY, PRECAUTIONS AND SYMBOLS
2.1 Signal words, instrucons and warnings 4
2.2 Precauons and safety instrucons 4
2.3 Residual risks 6
2.4 Symbols and abbreviaons 6
3. PRODUCT DETAILS
3.1 Idencaon 7
3.2 Descripon 8
3.3 Applicaon 8
3.4 Dimensions 9
3.5 Technical specicaons 10
4. INSTALL INSTRUCTIONS
4.1 Special tools and equipment 12
4.2 Installaon 13
5. CONNECT INSTRUCTIONS
5.1 Electrical material 13
5.2 Protecon - Condions and starng points 14
5.3 Overview and funcon diagram 15
5.4 Wiring diagram: Control board (RCB) 15
5.5 3-phase electric motor (208-600 VAC) 16
5.6 1-phase 3-wire electric motor (115-230 VAC) 17
5.7 1-phase 5-wire electric motor (115-230 VAC) 17
5.8 Automac control (ACS) (24 V AC/DC) 18
5.9 OPTIONAL - Manual control (MC) 18
5.10 OPTIONAL - Posion Feedback (RPU) 19
5.11 OPTIONAL - Alarm (AL) 20
6. USER INSTRUCTIONS
6.1 Usage - Condions and starng points 21
6.2 Status LEDs 21
6.3 Operaon 22
6.4 Alarm 23
6.5 Safety funcons and stop funcons 23
7. COMMISSIONING INSTRUCTIONS
7.1 Commissioning - Condions and starng points 24
7.2 Check: Control direcon of the Automac Control (ACS) 25
7.3 Check: Control direcon of the Manual Control (MC) 26
8. MAINTENANCE INSTRUCTIONS
8.1 Maintenance 27
9. SERVICE
9.1 Troubleshoong 27
9.2 Blink codes 28
9.3 Technical support 29
10. ENVIRONMENT
10.1 Decommissioning and removal 30
10.2 Waste disposal 31
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
2

1. GUIDELINES, STANDARDS AND CONDITIONS
1.1 Applicable guidelines and standards
This product complies with the provisions of the European guidelines that follow:
Machinery Direcve 2006/42/EC | Low Voltage Direcve 2006/95/EC | EMC Direcve 2004/108/EC
The harmonized standards (or parts of these standards) that follow are applicable:
NEN-EN-ISO 12100:2010 | NEN-EN-IEC 60204-1 |
NEN 82079-1 (62079: 2001) | NEN5509 | ISO 3864-2
Make sure that this product is only put into operaon if the system (in which it will be installed)
complies with the provisions of the applicable standards and guidelines.
1.2 Approved personnel
This product manual contains important informaon for installers about the installaon and
commissioning of a Ridder LogicLink RLL400 control-unit. Read this product manual and instrucons
rst before the work starts. Approved mechanical and/or electrical installers, with professional
competence, must do all work safe and responsible.
TARGET GROUP FOR EACH CHAPTER CHAPTER (refer to Table of Contents)
TARGET GROUP 1 2 3 4 5 6 7 8 9 10
User (operator) • • • • (•)
Installer / Approved personnel • • • • • • • • • •
(•) = Not fully applicable
Keep this product manual with the product during the lifespan. Make sure it is available for users
(operators), installers and approved personnel.
1.3 Warning about discouraged use
The condions that follow are applicable:
• Do not change (the construcon of) the LogicLink RLL400 control-unit.
• It is not permied to use the RLL400 control-unit to li or move people.
• Do not let the torque of the motor gearbox be more than its maximum.
• Do not let the duty cycle of the motor gearbox be more than its maximum.
Refer to §3.3 for a descripon of the intended use.
1.4 Warranty provisions
For the warranty period and condions refer to the ‘Condions’ secon on our website at ridder.
com, or in the Ridder catalogue.
Regulatory Conformity
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
3

2. SAFETY, PRECAUTIONS AND SYMBOLS
2.1 Signal words, instrucons and warnings
Signal words (ISO 3864-2)
This product manual contains safety instrucons with dierent signal words. The list that follows
gives the risk levels and possible eects of each signal word.
Instrucons and warnings on the product
Read the product manual to fully know all product properes,
before it is used or work starts!
Ê
It is not permied to use high-pressure cleaners (and related
cleaning agents)! Use a so brush with a small quanty of water
without cleaning agents.
Warning - Electrical voltage
Aer installaon interchange the plug in the highest posion
with the vent plug! Refer to the permied mounng posions in
the product manual.*
* Not applicable to the RW45 motor gearbox!
2.2 Precauons and safety instrucons
Precauons
GENERAL
A system can be dangerous. Safety precauons and instrucons are important.
• If these precauons cannot be obeyed, then use warnings.
Suggeson to perform an operaon more eecve.
May result in damage or problems if an acon is performed
incorrectly.
May result in minor injury if the hazard is not avoided.
Signicant injury, possible death, if the hazard is not avoided.
Severe injury and possible death if the hazard is not avoided.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
4

• The responsibility for precauons and warnings lies with the installer of the system. Refer to the,
local or naonal, laws and regulaons of the country if a cercaon (mark) is necessary.
• Parts of the electrical or electronic installaons are connected to dangerous electrical voltages.
Work without professional competence or not obeyed warning instrucons could cause injury
and/or material damage.
• Ridder is not responsible for injury, material damage or consequenal damage if accessories are
used that Ridder did not make.
TRANSPORT, STORAGE AND PACKAGING
The condions and instrucons that follow are applicable.
• Ambient temperature: -15 to +60 °C (+5 to +140 °F).
• Ambient: A not-condensed relave humidity is necessary.
• Do a check for transport damage and missing parts immediately on incoming goods.
• Tell damages and missing parts immediately to the transport company and to your local Aer
Sales contact person.
• Do not use damaged products and if necessary do not start the work.
• Send the product to the installaon site before it is removed from the (sealed) packaging. This
prevents damage (from mechanical shocks) to the product.
• Use applicable means-of-transport with dimensions which are sucient. Use (if necessary) the
correct work equipment and accessories. Refer to “Dimensions” and “Technical specicaons”.
Make sure that the working condions comply with the, local or naonal, laws and regulaons.
• Make sure that storage areas and the areas in the means-of-transport are dry and the airow is
sucient.
• Make sure that the products do not touch the (moist) boom surface of storage areas and of the
means-of-transport (use pallets or such). The boom surfaces must be smooth.
• Make sure that the products are protected from dust, dirt and direct sunlight.
• Apply an applicable corrosion-prevenve agent to surfaces that are not painted.
• Aer installaon discard the packaging and obey the applicable naonal and/or local regulaons.
Safety instrucons
• Use (if applicable) personal protecve-equipment for protecon which agrees with the dierent
types of work.
• Do not let persons and not approved personnel be near controls and systems in operaon.
• Damaged systems must be stopped immediately unl they are repaired.
• Use safety barriers, for system parts that move, to a height of 2.5 m from the ground.
• The safety distance to the danger zone (if applicable) must agree with ISO 13857:2008.
• Do not operate systems when persons are in the danger zone and can touch the system.
• Monitor the danger zone when you work with or near the system.
• Stop and de-energize systems during maintenance and cleaning work on or near the system.
• Make sure that there is sucient space between parts that move and adjacent objects.
• Stay away from or safety areas where there is a risk to become caught in a system that moves.
• The torque and the duty cycle of the system must be in the range of the motor gearbox
parameters. Refer to the product manual of the used Ridder motor-gearbox at ridder.com.
If you do not obey the safety instrucons that follow it can be
dangerous and cause injury.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
5

2.3 Residual risks
Automac controls
The Ridder drive-units are usually used in automac controlled systems. Persons who do work or
stay near the system must know about that. If persons or their clothes touch the system during
operaon, it can be dangerous.
Forces
Because of the forces in the systems (in which the drive unit is installed), Ridder cannot be sure that
there will be no injury to persons or damage to the system.
2.4 Symbols and abbreviaons
This secon tells about used symbols and abbreviaons in this manual. The table that follows gives
the descripons.
Symbol Description Symbol Description
1L1 Power IN (A2) MC Manual Control (external)
3L2 Power IN (A2) MPCB Motor-Protecon Circuit-Breaker
5L3 Power IN (A2) N Neutral wire
2T1 Power OUT (EM) PE Protecve earth
4T2 Power OUT (EM) PTC PTC thermistor
6T3 Power OUT (EM) RCB Ridder control-board
ACS Automac control-system RLL Ridder LogicLink
AL Alarm (circuit) RLS Limit-switch system
A1 RLL400 housing RPU Digital posioning-meter
A2 Control board RSU Limit-switch system
D1 Status LED - Green RW Motor gearbox
D2 Status LED - Red X1 Power input (RCB)
D3 Status LED - Red X2 Power output (EM)
D4 Status LED - Red X3 Transformer
EM, M Electric motor, Motor X4 PTC input
ES11,ES12 Duty switch RSU/RLS X5 Fault-contact output
ES21,ES22 Safety switch RSU/RLS X6 Automac-control input
GND Return wire of control signal (ACS) X7 RPU reference-input
ICurrent in Amperes (A) X8 Manual-control input
L1, L2, L3 Voltage source X9 Limit-switch input
Persons can be in danger of life if they touch a system that is in
operaon.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
6

3. PRODUCT DETAILS
3.1 Idencaon
EXAMPLE
Ê
This product manual is only applicable to:
• Ridder LogicLink RLL400 control-unit
• Serial numbers from 200.900.000
• Item numbers from 500000.
Idencaon is possible from the scker on the locaon shown.
Refer to the explanaon that follows on how to read the informaon.
For more informaon on item numbers and models refer to the
Ridder catalogue or website at ridder.com.
RW1400: RW1000 /1400, RW1200/1600S or RW2000S.
1-5D: 1~ mains voltage, 5-wire electric motor.
Alternatives
1-3: - 1~ mains voltage, 3-wire electric motor.
- 3~ mains voltage.
3: 3~ mains voltage.
Alternatives
115-400: Mains voltage 115 V/230 V (1~) or 208 V/400 V (3~).
RLL400: General designaon Ridder RLL400 control units.
1~ = 1-phase
= No symbol in idencaon. RW45, RW200, RW240/400/600 or RW800 motor gearbox.
( - ): RW45, RW200, RW240/400/600 or RW800.
3~ = 3-phase
400: Mains voltage 400 V (3~).
440-600: Mains voltage 440 V, 480 V or 600 V (3~).
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
7

3.2 Descripon
The RLL400 is a control unit to control a Ridder RW motor-gearbox. The
control unit is part of drive units with motor gearboxes type RW45,
RW200, RW240/400/600, RW800, RW1000 /1400, RW1200/1600S or
RW2000S.
The control unit is applicable to:
• Dierent supply voltages
• Dierent mains frequencies
• 3-phase and 1-phase voltages.
The control unit has a control board with a microprocessor and a semiconductor relay.
The control board has connecons for:
• The supply voltage
• The power supply for the electric motor (EM)
• An automac control signal (24 V AC/DC) from an automac control-system (ACS)
• A manual control (MC)
• A fault contact (NC) that can be part of an alarm circuit
• The PTC thermistor in the electric motor (EM) (if applicable) for thermal protecon
• A digital posioning-meter (RPU).
The limit-switch system is also connected to the control board of the control unit.
The RLL400 control-unit transmits control signals from the automac control-system (ACS) or
manual control (MC) and monitors if these are processed without malfuncons. The control unit has
rotaonal-eld detecon and phase detecon of the supply voltage.
The 24 V AC/DC control input is protected from:
• Control in two direcons at the same me
• Sudden changes of direcon.
The control unit has status LEDs to show error messages of the system.
The RLL400 control-unit has plug connectors and terminal strips to connect the cables. To pull the
cables through, out of the housing, the control unit also has cable glands. The protecon rang of
the RLL400 housing is IP54.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
8

3.3 Applicaon
The LogicLink RLL400 control-unit is installed, as part of a drive unit, on dierent RW motor-
gearboxes. The control-unit is used to control the motor gearboxes in two direcons-of-rotaon.
The RLL400 control-unit (on dierent RW motor-gearboxes) is applicable to:
• Venlaon systems
• Screen systems.
For other (dierent) applicaons, approval from Ridder Drive Systems is necessary.
3.4 Dimensions
Note: The dimensions and illustraons are approximate. In this product manual shown illustraons
can be dierent than the components and/or systems.
M16(4x)
200
90
64
90
70
490 182
268.5
M20(3x)
Example:
M16(4x)
200
64
90
70
490 182
268.5
M20(3x)
Example:
M20(1x)
503.5
117
83
78
150
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
9

3.5 Technical specicaons
Mechanical
Dimensions (WxHxD) RW45 - RW800: 490 mm x 90 mm x 200 mm
RW1000 - RW2000: 503.5 mm x 117 mm x 200 mm
Weight 3.1 - 5.4 kg
Ambient
Protecon rang IP54
Ambient temperature 0 to +60 °C (+32 to +140 °F)
Maximum relave humidity 95%
The three types of control boards (RCB) that follow
are available for the RLL400 control-unit.
RCB-A (Type A):
50/60 Hz AC
1~ 115V-230 V, 12FLA, 72 LRA
3~ 208-400 V, 12 FLA, 72 LRA
RCB-B (Type B):
50/60 Hz AC
3~ 400 V, 10 FLA, 60 LRA
RCB-C (Type C):
50/60 Hz AC
3~ 440-600 V, 10 FLA, 60 LRA
Refer to the table that follows for abbreviaons,
technical specicaons and descripons of all
connecons.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
10
Indice
Altri manuali Ridder Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente