Rinnai Control-R Manuale utente

Recirculaon with On-Demand Accessories User Guide 1
ENGLISH

Recirculaon with On-Demand Accessories User Guide
2
This manual provides detailed informaon on Rinnai’s on-demand
recirculaon accessories; it is designed for eld installers and is a
supplement to the Control-R™ Wi-Fi Module Installaon Manual
(supplied inside module package).
1 What is Recirculaon?.....................................3
Recirculaon Components ........................................ 3
Tankless Water Heaters with Circ-Logic.................... 4
How On-Demand Recirculaon Works.................... 5
Recirculaon with a Dedicated Return Line............. 8
Recirculaon with a Crossover Valve ................... 11
2 Let’s Get Started ........................................... 12
Step 1: Install Module.......................................... 12
Step 2: Connect Module to Water Heater and
Congure Sengs ...................................... 12
Step 2A: SENSEI™ Models .................. 13
Step 2B: Non-SENSEI™ Models........... 23
Step 3: Tesng Accessories with Circ-Logic............. 31
3Installaon Tips ............................................ 32
4Frequently Asked Quesons ......................... 33
Appendix A: Install the Module on a Wall ...........36
Appendix B: Addional Parameter Sengs.........38

Recirculaon with On-Demand Accessories User Guide 3
Circ-Logic is Rinnai’s recirculaon technology built into Rinnai Tankless
Water Heaters. Circ-Logic denes recirculaon paerns that coincide
with your hot water usage. Hot water is available when and where you
want it with the on-demand recirculaon components listed below.
Mounts in a convenient locaon, such as a kitchen
faucet or bathroom sink and operates the recirculaon
system by pushing the buon.
Mounts ush to the wall or in the corner and operates the
recirculaon system with the detecon of moon.
Turns o recirculaon and is available for purchase if
required by local building codes.
Start recirculaon with a simple voice
command with Amazon Alexa or Google Home.
Amazon, Alexa and all related logos are trademarks of Amazon.com,
Inc. or its aliates. Google Home is a trademark of Google LLC.
Once connected and the Rinnai app is downloaded, the
Rinnai Tankless Water Heater can be controlled from the
user’s smart phone or tablet.

Recirculaon with On-Demand Accessories User Guide
4
Models with Recirculaon Capability
With
Internal Pump
Without
Internal Pump
Circ-Logic is included in Rinnai’s
SE+ Series featuring Therma-
Circ360™ models (Super High
Eciency Plus RUR Models):
• RUR98i/e
• RUR160i/e
• RUR199i/e
Included in these models are an
internal recirculaon pump and
crossover valve.
The following models include Circ-
Logic, but require installaon of
an external recirculaon pump
(purchased separately):
• RLX94i
• RL75i/e (VC)
• RL94i/e (VC)
• RU80i/RUC80i and RU80e
• RU90e/RUC90i
• RU98i/RUC98i and RU98e
SENSEI™ Models:
• CU199i/e (Commercial)
• CU160i/e (Commercial)
• RU199i/e (Residenal)
• RU180i/e (Residenal)
• RU160i/e (Residenal)
• RU130i/e (Residenal)
Example image

Recirculaon with On-Demand Accessories User Guide 5
The on-demand accessory is acvated (push buon is pressed,
moon sensor acvated, etc.)
A request (not a command) is sent to the water heater to turn on
the pump. In other words, the push buon or moon sensor is
asking the water heater if the pump can turn on to start
recirculaon.
With built-in Circ-Logic, the water heater decides (based on me
intervals and current water temperature) if the pump can turn
on. The water heater either ignores or accepts the request from
the recirculaon accessory.
If the water heater accepts the request to start recirculaon, the
pump turns on and runs for ve minutes or unl the water
temperature is reached (whichever occurs rst).
Aer recirculaon completes, the pump enters into a mandatory
dormant (inacve) state. During this me, the pump will not
turn on for any reason, even if the push buon or moon
sensor is acvated.
The pump remains dormant for the congured me intervals.
See Visual Illustraon on Next Page

Recirculaon with On-Demand Accessories User Guide
6
IF REQUEST IS
ACCEPTED
SENDS
REQUEST
CAN THE
PUMP TURN ON?
Circ-Logic decides if
the pump will turn on
(based on congured
me intervals and
current water
temperature).
WATER HEATER
IGNORES OR
ACCEPTS REQUEST
Pump turns on and runs
for 5 minutes or unl
water temperature is
reached (whichever
occurs rst).
Pump turns o and enters into a
mandatory dormant (inacve) state.
DURING THIS TIME, THE PUMP
WILL NOT TURN ON FOR ANY
REASON, EVEN IF THE PUSH
BUTTON IS PRESSED
The pump remains dormant for the
congured me intervals.
PUMP ON
5 MIN. PUMP OFF
15 MIN.*
Push buon
is pressed.
On-Demand Recirculation Example
* 15 Minutes is an
example me frame
and is for illustrave
purposes only.
RECIRCULATION
CYCLE COMPLETE

Recirculaon with On-Demand Accessories User Guide 7
IMPORTANT: If an on-demand request is made while the
pump is dormant, the pump WILL NOT turn back on.
The ON signal is sll sent to the water heater for a 5-minute mer. If
the dormant period completes with me available on the Control-R™
mer, the pump will acvate for those remaining minutes (see
example below).
5-minute recirculaon mer aer the
on-demand accessory is acvated.
Interval when the on-demand
accessory is acvated.

Recirculaon with On-Demand Accessories User Guide
8
Pump OFF intervals (the amount of me the pump stays o) are
dierent for RUR models and non-RUR models:
• RUR models include an integrated recirculaon pump
• Non-RUR models that are equipped with Circ-Logic require
installaon of an external recirculaon pump
Rinnai Temperature
Seng °F
Typical Pump OFF Intervals (Minutes)
Economy Mode Comfort Mode
140 18 9
135 20 10
22 11
130
125 24 12
120 28 14
115 32 16
110 38 19
108 40 20
106 44 22
104 48 24
102 52 26
100 56 28
98 62 31
RUR Models (Include Internal Recirculaon Pump)

Recirculaon with On-Demand Accessories User Guide 9
• The push buon or moon sensor is acvated.
• If the water heater accepts the request, the pump runs for ve minutes
(or unl the water temperature is reached) and then turns o.
• The pump remains o in its mandatory dormant (inacve) state for 24
minutes in Comfort mode.
If using a dedicated return line, set the dip switches as outlined in the
Tankless water heater Installaon and Operaon Manual.
Note: Instead of dip switches, SENSEI™ units have parameter sengs.
Temperature Economy Comfort
104 48 24
Comfort mode is recommended with on-demand recirculaon
accessories as it cycles the pump more frequently, ensuring the loop
temperature remains higher.
1234512345
1—24 Minutes
Pump ON
5 Min.
Pump OFF
24 Min.
Pump runs for 5 minutes or unl water temperature
is reached (whichever occurs rst).
Pump ON
5 Min.
Pump WILL NOT turn on
TIP
IMPORTANT
If a push buon or moon sensor is acvated during
the mandatory dormant (inacve) state, the pump
WILL NOT turn back on.
• Aer 24 minutes, the push buon or moon sensor may be
acvated to turn on the pump.

Recirculaon with On-Demand Accessories User Guide
10
Rinnai Temperature
Seng °F
Typical Pump OFF Intervals (Minutes)
Economy Mode Comfort Mode
140 31 15
135 31 15
31 15
130
125 31 15
120 31 15
115 35 18
110 42 21
108 45 22
106 49 24
104 54 27
102 60 30
100 68 34
98 79 39
Non-RUR Models (External Recirculaon Pump Required)
Altri manuali per Control-R
3
Indice
Altri manuali Rinnai Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente