I Product Intro ……………………………………………………………………………………… .. …… .2
II General Safety Rules ……………………………………………………………………………… .. 2
III Major Functions ……………………………………………………………………………………… ..2
IV Operation Precautions ………………………………………………………………………………… ..3
V General Inspection ……………………………………………………………………………………… . 3
VI Functional Inspections.............................................................................................................................. 3
VII Battery Recharging Instruction ……………………………………………………………………… .3
VII Firmware Upgrades …………………………………………………………………………………… .3
I X Product Familiarization ……………………………………………………………………………… . 5
1. Interface and Buttons ……………………………………………………………………………… 5
2. Screen ……………………………………………………………………………………………… 5
X Measurement Operation Instruction ………………………………………………………………… .6
1. Parameter Area Intro ………………………………………………………………………………… 6
2. Measurement Area Intro ……………………………………………………………………… 6
3. Specific Parameter s Intro ……………………………………………………………………… 6
XI Application Examples ……………………………………………………………………………… .9
1. Example One: Measure Simple Signal …………………………………………………………… 11
2. Example Two : Measure with Cursor ……………………………………………………………… 12
3. Example Three : Save Waveform Image …………………………………………………………… 13
4. Example Four : Acquire Single Signal ……………………………………………………………… 14
5. Example Five : Compare Waveform Signals ……………………………………………………… 15

2
I
Product
Product
Product
Product Intro
Intro
Intro
Intro
DSO Nano pocket size oscilloscope is a compatible 32bit digital storage oscilloscope. Based on ARM -M3,
i t
’
s equipped with 320*240 color display, SD card, USB port and recharging function. It
’
s compact, simple to
operate; meets the basic demands of school lab, electric furniture repairmen and electric engineering.
II
General
General
General
General Safety
Safety
Safety
Safety Rules
Rules
Rules
Rules
To ensure your safety & avoid any damages to the product/connected devices, please read the following
safety rules carefully. To avoid any possible dangers, please use this product according to the rules.
Use
Use
Use
Use appropriate
appropriate
appropriate
appropriate power
power
power
power cord.
cord.
cord.
cord. Please use dedicated power cord which is certified in the country/region.
Connect/disconnect
Connect/disconnect
Connect/disconnect
Connect/disconnect properly.
properly.
properly.
properly. Do not plug/unplug when the probe(s)/test lead ( s ) is connected to the
power source . Before you plug/unplug the current probes, please disconnect the power to the circuit-under-test.
Observe
Observe
Observe
Observe all
all
all
all terminal
terminal
terminal
terminal ratings.
ratings.
ratings.
ratings. To avoid fire/electric shock, please don ’ t measure signal with DC100V or
above, or the device might be destroyed. Please read the manual carefully to know the detailed info of related
ratings before connection.
Please
Please
Please
Please do
do
do
do not
not
not
not operate
operate
operate
operate in
in
in
in humid
humid
humid
humid environment.
environment.
environment.
environment.
Please
Please
Please
Please do
do
do
do not
not
not
not operate
operate
operate
operate in
in
in
in inflammable/explosive
inflammable/explosive
inflammable/explosive
inflammable/explosive environment.
environment.
environment.
environment.
Please
Please
Please
Please keep
keep
keep
keep the
the
the
the surface
surface
surface
surface of
of
of
of the
the
the
the product
product
product
product clean
clean
clean
clean and
and
and
and dry.
dry.
dry.
dry.
III
Major
Major
Major
Major Functions
Functions
Functions
Functions
Display 2.8 ” color TFT LCD
display resolution 320 × 240
Display Colors 65K
Virtual Broadband 0-200kHz
Max. Sampling Rate 1Msps 12 bit
Sampling Storage Depth 4096 points
Transverse Sensitivity 1uS/Div~10S/Div(1-2-5 stepping)
Vertical Sensitivity 10mv/Div~10V/Div(x1 probe)
0.5V/Div~10V/Div(x10 probe)
Input Resistance >500K Ω
Max. Input Voltage 80Vpp (x1 probe )
Coupling Mode DC
Triggering Mode Auto ,Normal ,Single ,None ,Scan
Auto Measurement
frequency ,cycle ,duty ,Vpp ,Vram ,
Vavg
,DC voltage
Vertical Precise Measurement Cursor
Horizontal Precise Measurement Cursor
Rising/Falling Edge Trigger
Triggering Cursor
Triggering Sensitivity Cursor
Hold/Run
Inbuilt Test Signal 10Hz~1MHz(1-2-5 stepping)
Waveform Storage 2Mbyte
PC Connection Interface Connection through USB
Recharging Method Recharging through USB interface
Dimensions 105mm × 53mm × 8mm

3
IV
Operation
Operation
Operation
Operation Precautions
Precautions
Precautions
Precautions
▌Temperature :
Working condition :+0 ℃to +500 ℃
Non-working condition :-20 ℃to +60 ℃ :
▌Humidity :
Working condition :High temperature :40 ° C - 50 ° C ,0%-60%RH
Working condition :Low temperature :0 ° C - 40 ° C ,10%-90%RH
Non-working condition :High temperature :40 ° C- 60 ° C ,5%-60%RH
Non-working condition :Low temperature :0 ° C - 40 ° C ,5%-90%RH
VGeneral
General
General
General Inspection
Inspection
Inspection
Inspection
When you get a new DSO Nano , it
’
s suggested to inspect the product by the following steps:
1.Inspect for damage caused by shipping.
If the carton / plastic protection pad is seriously damaged, please keep the package until the product and
accessories pass the inspection electrically and mechanically.
2.Inspect the product
Please contact the company if the following problems occur : 1) product surface is damaged, 2) product
doesn ’ t work properly, 3) product does not pass performance test.
If the damage is resulted from shipping, please keep the package and contact the transportation department/
RIGOL distributor who is in charge of this service, for repair or exchange.
VI Functional
Functional
Functional
Functional Inspection
Inspection
Inspection
Inspection
Make a quick functional inspection to ensure the product is working soundly. Please perform following steps:
1.Turn on the power supply, access homepage of the oscilloscope.
2.Connect the oscilloscope with standard signals (e.g. square wave 20KHz ,Vpp=5V), set the switch on
probe tip as 1X, plug oscilloscope probe to the jack .
Check whether the measured signal value is the same as the standard value; it can be calibrated if the
margin is small.
VII
Battery
Battery
Battery
Battery Recharging
Recharging
Recharging
Recharging Instruction
Instruction
Instruction
Instruction
When the battery sign shows as “ ” , or when the display is dim, please recharge in time. The product can
be power on or off while recharging .
VIII
Firmware
Firmware
Firmware
Firmware Upgrade
Upgrade
Upgrade
Upgrade
To upgrade firmware, please perform following steps:
1. Open web to access www.minidso.com , download the latest applicable firmware to your PC.
2. Simultaneously press “ ▼ ” and turn on power supply, enter DFU firmware upgrade mode.
3. Use USB to connect DS O Nano to your PC, a removable disk named DFU V3_ 22 _A will appear on
your PC. Copy the hex firmware to the root directory of your disk. After the extension of the firmware
changes from “ hex ” to “ rdy ” , reboot , thus firmware is upgraded.

4
IX
Product
Product
Product
Product Familiarization
Familiarization
Familiarization
Familiarization
1.
1.
1.
1. Interface
Interface
Interface
Interface &
&
&
& Buttons
Buttons
Buttons
Buttons
1. Copy file from PC to the virtual USB disk
2. After extension changes from “ hex ” to
“ rdy ” , it
’
s upgraded.

5
2.
2.
2.
2. Screen
Screen
Screen
Screen
The
The
The
The screen
screen
screen
screen display
display
display
display is
is
is
is depicted
depicted
depicted
depicted as
as
as
as below:
below:
below:
below:
Parameter Area
Measurement
Area
Parameter Area
Display the position of
current waveform
A B C D E F G H

6
The table below show s the intro of button functions
Button Function
A
�
||
Run/Hold
Choose to save current parameter setting(long press)
▲ Upward selection
▼ Downward selection
◄(left/decrease )change setting parameters
►(right/increase )change setting parameters
OK Menu
Choose to save current file(long press)
NOTE :There are corresponding colors for items in Parameter A rea and Measurement A rea.
XMeasurement
Measurement
Measurement
Measurement Operation
Operation
Operation
Operation Instruction
Instruction
Instruction
Instruction
1. Parameter Area Intro
Menu Item Function(Operate: Press ◄ or ► )
A AUTO/NORM/SINGL/NONE/SCAN Automation/ Normal /Single/Slow
Scan/Instant Scan
B 10mV-10V (1-2-5 stepping )y-axis voltage per grid
C× 1/ × 10 multiple
D 1uS — 2S (1-2-5 stepping )x-axis voltage per grid
E -Inp/Data/-Data/Inp+D/D-Inp/Inp-D Operation of 2 waveforms (Inp is
current waveform; D/Data is
previously saved waveform)
F Triggering Method: Falling edge
trigger, Rising edge trigger.
G±40mV —± 3.9V Horizontal triggering range
H
/
Power supply by battery/ by USB
2. Measurement Area Intro
Item Function Intro
Yn Y-axis Function Setting
Xn X-axis Function Setting
Tr Triggering Function Setting
Me Measurement Function Setting
Ex Waveform Operation Function Setting
Fn Save and Load Function Setting
Sn Output Waveform Parameters Setting
Ca Calibration Setting
3. Specific Parameter Intro
Choose the items in parameter area through “ ▲ ” or “ ▼ ” . Pres s “ OK ” to access parameter setting menu, use
“▲” and “ ▼” to choose the parameter item, and then use “ ◄ ” and “ ► ” to change the parameter value of the
place where the cursor blinks.
(1)Annotation of Yn parameters

7
Y Ranges Y-axis voltage per grid
ProbeAtt Multiple
FitRange Auto adjustment
Y Offset Waveform adjust s up & down within the win d ow
CursorV1 Cursor V1:top limit of visible trigger level
CursorV2 CursorV2:bottom limit of visible trigger level
CursorTp Hide/ Display Measurement Cursor
(2)Annotations of Xn Parameters
TimeBase X-axis voltage per grid
Fit Base Auto adjustment

8
ViewPosi Horizontal movement to view waveform
SmplDpth Internal storage depth (1k ~6k )
CursorT1 Time measurement cursorT1
CursorT2 Time measurement cursorT2
CursorTp Hide/Display Measurement Cursor
(3)Annotations of Tr parameters
SyncMode
Choice s of Triggering Mode
AUTO/NORM/SINGL/NONE/SCAN
Automation/Normal/Singular/Slow Scan/Instant Scan
TrigMode Rising edge/falling edge triggering mode
Auto Fit Auto adjustment
Threshol Horizontal Triggering Position Level
Sensitiv Horizontal Triggering Range
CursorTp Hide/Display Horizontal Triggering Position Level
(4)Annotations of Me Parameters

9
Freq Signal Frequency
Duty Dutyfactor
Vrms Voltage Effective Value
Vavg
Average Value of V oltage
Vp-p Peak-to-Peak Voltage
Vmax Maximum Voltage
Vmin Minimum Voltage
(5)Annotations of Ex Parameters
Ext Refn 2 waveforms operation (Inp is current waveform; D/Data is
previously saved waveform)
-Inp/Data/-Data/Inp+D/D-Inp/Inp-D

10
Ext Posi Display current waveform
(6)Annotations of Fn Parameters
Save Bmp Save bmp file (waveform image) to the built-in U disk
Save Dat Save dat file to the built-in U disk
Save Buf Save buf file (sampling buffering data) to built-in U disk
Save Csv Save csv file (export sampling buffering data)to built-in U disk
Load Dat load Dat
Load Buf load Buf
(7)Annotations of Sn Parameters
Out Freq Signal output frequency
Out Duty Signal output dutyfactor
Questo manuale è adatto per i seguenti modelli
1
Indice
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione