Standard Features for Cat Series 4 Entrance Expansion Module
The Cat Series 4 Entrance Expansion Module contains a
terminal block (J16) that provides an logical low output for each
relay output. They can be used to activate display LED’s on the
readers to indicate acceptance. The entrance indicated will de-
pend on the setting of SW1.
The Cat Series 4 Entrance Expansion contains a ter-
minal block (J3) to individually activate the REX (Request to
Exit) and when the input terminals are shorted or pulled to com-
mon. You may use dry relay contacts or transistor pull-downs
referenced to circuit common. Each input has a LED located
just to the right of the terminals to indicate when that input is on.
When each input is closed the output relay will be activated for
the time programmed by the Relay Timing Selector Switch and
then the relay will return to its normal state even if the input re-
mains closed.
- +
Location of
BAT termi-
nals with Po-
larity Marks
BAT
Input Terminals and Relay Outputs
Terminal
ID Terminal De-
scription (SW1)
Entrance
1 2 3
Relay Function
R0 REX 5, 9, 13 RLY0 Entr. Control
S0 Sense 5, 9, 13 RLY1 Alarm Shunt
R1 REX 6, 10, 14 RLY2 Entr. Control
S1 Sense 6, 10, 14 RLY3 Alarm Shunt
R2 REX 7, 11, 15 RLY4 Entr. Control
S2 Sense 7, 11, 15 RLY5 Alarm Shunt
R3 REX 8, 12, 16 RLY6 Entr. Control
S3 Sense 8, 12, 16 RLY7 Alarm Shunt
J7 located at the bottom of the board on the right
side maybe used to turn off all the relays at once by
opening the connection. This connector is normally
shipped with a Jumper installed. This could be used with
dry contacts opening on an external signal in conjunction
with J5 settings (J5 connected is fail safe) to de-energize
the relays during emergencies.
The relay outputs are type Form C (one normally open
and one normally closed contact) rated at 3 amps 24 v
ac/dc. Each relay has a LED (light emitting diode) next to
it indicating when the relay is energized.
The BAT connections allow a backup battery to be
connected. (SES Part No. B12V) This allows the unit to
continue to operate during short power interruptions
(approx 1 hour). Circuitry is included to charge and
maintain the battery. Note: Do not use these terminals
to power other devices.
J16 Outputs
Output Entr.
0 5, 9, 13
2 6, 10, 14
4 7, 11, 15
6 8, 12, 16