SICK DC12-24V Manuale utente

OPERATING INSTRUCTIONS
picoCam2
2D machine vision

Described product
picoCam2
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK
Subject to change without notice

Contents
1 About this document........................................................................ 5
1.1 Information on the operating instructions.............................................. 5
1.2 Explanation of symbols............................................................................ 5
1.3 Further information................................................................................... 6
2 Safety information............................................................................ 7
2.1 Intended use............................................................................................. 7
2.2 Improper use............................................................................................. 7
2.3 Limitation of liability................................................................................. 7
2.4 Modifications and conversions................................................................ 7
2.5 Cybersecurity............................................................................................ 8
2.6 Requirements for skilled persons and operating personnel.................. 8
2.7 Operational safety and specific hazards................................................. 8
3 Product description........................................................................... 10
3.1 Scope of delivery....................................................................................... 10
3.2 Status indicators....................................................................................... 10
4 Transport and storage....................................................................... 11
4.1 Transport................................................................................................... 11
4.2 Unpacking.................................................................................................. 11
4.3 Transport inspection................................................................................. 11
4.4 Storage...................................................................................................... 11
5 Mounting............................................................................................. 12
5.1 Mounting instructions............................................................................... 12
5.2 Mounting the device................................................................................. 12
6 Electrical installation........................................................................ 13
6.1 Wiring instructions.................................................................................... 13
6.2 Prerequisites for safe operation of the device........................................ 13
6.3 Connecting the device electrically........................................................... 14
7 Operation............................................................................................ 16
7.1 Operation using SICK Vision Suite........................................................... 16
8 Maintenance...................................................................................... 17
8.1 Maintenance plan..................................................................................... 17
8.2 Cleaning..................................................................................................... 17
9 Troubleshooting................................................................................. 18
9.1 General faults, warnings, and errors....................................................... 18
9.2 Repairs...................................................................................................... 18
9.3 Returns...................................................................................................... 18
9.4 Disposal..................................................................................................... 18
CONTENTS
8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 3
Subject to change without notice

10 Technical data.................................................................................... 19
10.1 Dimensional drawing................................................................................ 19
10.2 Features.................................................................................................... 19
10.3 Mechanics/electronics............................................................................. 20
10.4 Performance............................................................................................. 20
10.5 Interfaces.................................................................................................. 20
10.6 Ambient data............................................................................................. 20
11 Accessories........................................................................................ 22
12 Annex.................................................................................................. 23
12.1 Declarations of conformity and certificates............................................ 23
12.2 Copyright notices...................................................................................... 23
CONTENTS
4O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK
Subject to change without notice

1 About this document
1.1 Information on the operating instructions
These operating instructions provide important information on how to use devices from
SICK AG.
Prerequisites for safe work are:
•Compliance with all safety notes and handling instructions supplied.
•Compliance with local work safety regulations and general safety regulations for
device applications
The operating instructions are intended to be used by qualified personnel and electrical
specialists.
NOTE
Read these operating instructions carefully to familiarize yourself with the device and its
functions before commencing any work.
The operating instructions are an integral part of the product. Store the instructions
in the immediate vicinity of the device so they remain accessible to staff at all times.
Should the device be passed on to a third party, these operating instructions should be
handed over with it.
These operating instructions do not provide information on the handling and safe
operation of the machine or system in which the device is integrated. Information on
this can be found in the operating instructions for the machine or system.
1.2 Explanation of symbols
Warnings and important information in this document are labeled with symbols. Sig‐
nal words introduce the instructions and indicate the extent of the hazard. To avoid
accidents, damage, and personal injury, always comply with the instructions and act
carefully.
DANGER
…indicates a situation of imminent danger, which will lead to a fatality or serious
injuries if not prevented.
WARNING
…indicates a potentially dangerous situation, which may lead to a fatality or serious
injuries if not prevented.
CAUTION
…indicates a potentially dangerous situation, which may lead to minor/slight injuries if
not prevented.
NOTICE
…indicates a potentially harmful situation, which may lead to material damage if not
prevented.
NOTE
…highlights useful tips and recommendations as well as information for efficient and
trouble-free operation.
ABOUT THIS DOCUMENT 1
8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 5
Subject to change without notice

1.3 Further information
NOTE
Further documentation for the device can be found on the online product page at:
•www.sick.com/picoCam2
There, additional information has been provided depending on the product, such as:
•Model-specific online data sheets for device types, containing technical data,
dimensional drawing, and specification diagrams
•Declarations of conformity and certificates of the product family
•Dimensional drawings and 3D CAD dimension models of the device types in
various electronic formats
•Other publications related to the devices described here
•Publications dealing with accessories
1 ABOUT THIS DOCUMENT
6O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK
Subject to change without notice

2 Safety information
2.1 Intended use
The picoCam2 is an industrial streaming camera used to take images for visualization
and image processing tasks. It is designed for use in industrial environments.
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.2 Improper use
Any use outside of the stated areas, in particular use outside of the technical specifica‐
tions and the requirements for intended use, will be deemed to be incorrect use.
•The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.
•The device must not be used in explosion-hazardous areas, in corrosive environ‐
ments or under extreme environmental conditions.
•Any use of accessories not specifically approved by SICK AG is at your own risk.
WARNING
Danger due to improper use!
Any improper use can result in dangerous situations.
Therefore, observe the following information:
■Product should be used only in accordance with its intended use.
■All information in the documentation must be strictly observed.
■Shut down the product immediately in case of damage.
2.3 Limitation of liability
Relevant standards and regulations, the latest technological developments, and our
many years of knowledge and experience have all been taken into account when
compiling the data and information contained in these operating instructions. The
manufacturer accepts no liability for damage caused by:
■Non-adherence to the product documentation (e.g., operating instructions)
■Incorrect use
■Use of untrained staff
■Unauthorized conversions or repair
■Technical modifications
■Use of unauthorized spare parts, consumables, and accessories
2.4 Modifications and conversions
NOTICE
Modifications and conversions to the device may result in unforeseeable dangers.
Interrupting or modifying the device or SICK software will invalidate any warranty claims
against SICK AG. This applies in particular to opening the housing, even as part of
mounting and electrical installation.
SAFETY INFORMATION 2
8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 7
Subject to change without notice

2.5 Cybersecurity
Overview
To protect against cybersecurity threats, it is necessary to continuously monitor and
maintain a comprehensive cybersecurity concept. A suitable concept consists of organi‐
zational, technical, procedural, electronic, and physical levels of defense and considers
suitable measures for different types of risks. The measures implemented in this
product can only support protection against cybersecurity threats if the product is used
as part of such a concept.
You will find further information at www.sick.com/psirt, e.g.:
•General information on cybersecurity
•Contact option for reporting vulnerabilities
•Information on known vulnerabilities (security advisories)
2.6 Requirements for skilled persons and operating personnel
WARNING
Risk of injury due to insufficient training.
Improper handling of the device may result in considerable personal injury and material
damage.
■All work must only ever be carried out by the stipulated persons.
The following qualifications are required for various activities:
Table 1: Activities and technical requirements
Activities Qualification
Mounting, maintenance ■Basic practical technical training
■Knowledge of the current safety regulations in the workplace
Electrical installation,
device replacement
■Practical electrical training
■Knowledge of current electrical safety regulations
■Knowledge of the operation and control of the devices in their
particular application
Commissioning, configura‐
tion
■Basic knowledge of the computer operating system used
■Basic knowledge of the design and setup of the described
connections and interfaces
■Basic knowledge of data transmission
Operation of the device for
the particular application
■Knowledge of the operation and control of the devices in their
particular application
■Knowledge of the software and hardware environment for the
particular application
2.7 Operational safety and specific hazards
Please observe the safety notes and the warnings listed here and in other sections
of this product documentation to reduce the possibility of risks to health and avoid
dangerous situations.
2 SAFETY INFORMATION
8O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK
Subject to change without notice

WARNING
Electrical voltage!
Electrical voltage can cause severe injury or death.
■Work on electrical systems must only be performed by qualified electricians.
■The power supply must be disconnected when attaching and detaching electrical
connections.
■The product must only be connected to a voltage supply as set out in the require‐
ments in the operating instructions.
■National and regional regulations must be complied with.
■Safety requirements relating to work on electrical systems must be complied with.
WARNING
Risk of injury and damage caused by potential equalization currents!
Improper grounding can lead to dangerous equipotential bonding currents, which may
in turn lead to dangerous voltages on metallic surfaces, such as the housing. Electrical
voltage can cause severe injury or death.
■Work on electrical systems must only be performed by qualified electricians.
■Follow the notes in the operating instructions.
■Install the grounding for the product and the system in accordance with national
and regional regulations.
SAFETY INFORMATION 2
8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 9
Subject to change without notice

3 Product description
3.1 Scope of delivery
The delivery of the device includes the following components:
Table 2: Scope of delivery
No. of
units
Component Remarks
1 Device in the version ordered Depending on version
1 Printed Quick Start Guide, multi‐
lingual
Brief information and general safety notes
3.2 Status indicators
1
1
Figure 1: Status indicators
1LED
LED Description
LED flashes green quickly Device booting
LED flashes green slowly Device ready
LED lights up green Device open
LED lights up red No firmware loaded
3 PRODUCT DESCRIPTION
10 O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK
Subject to change without notice
Indice
Altri manuali SICK Accessori

SICK
SICK UC12 Manuale utente

SICK
SICK GTB2 Flat Series Manuale utente

SICK
SICK Inspector I10 Manuale utente

SICK
SICK TiM781 Manuale utente

SICK
SICK WTT190L-A Series Manuale utente

SICK
SICK TiM8P Series Manuale utente

SICK
SICK WTT190LC-B2233A00 Manuale utente

SICK
SICK PSS Prime Manuale utente

SICK
SICK deTec4 Core Guida utente

SICK
SICK OD5000 Series Manuale utente

SICK
SICK RSB Manuale utente

SICK
SICK W16 Manuale utente

SICK
SICK GRTE18S V Series Manuale utente

SICK
SICK T-EASIC FTS Manuale utente

SICK
SICK MPS-C Manuale utente

SICK
SICK LMS100 Manuale utente

SICK
SICK GTE6 Series Manuale utente

SICK
SICK TiM781 Manuale utente

SICK
SICK GTE6L Series Manuale utente

SICK
SICK VISIC100SF Manuale utente