2 FEATURES
Depending on your existing heating installation, the table below will help you identify the features offered by the product.
Electric heating with pilot wires Electric heating without pilot wires Boiler
“PRESENT” mode: Your heating programmer
manages the pilot wire of the radiators (Chauffage
SMS is at rest). If your installation is devoid of a
heating programmer, the control is managed by your
heater.
“ECO” mode: Chauffage SMS applies a frost
protection signal to the pilot wire on the radiators
(your heating programmer is disconnected from the
pilot wire of the radiators).
If you want to obtain a higher ECO temperature than
frost protection, it is necessary first to install a
temperature sensor and to set this setpoint by SMS.
Then make sure that the heating programmer is not
in the anti-freeze or off position.
“PRESENT” mode: Your heating
programmer manages the regulation of your
radiators (Chauffage SMS is at rest). If your
installation is devoid of a heating
programmer, the control is managed by your
heater.
“ECO” mode: Chauffage SMS manages
the control of your radiators from the
temperature setpoint defined by SMS. In the
absence of a temperature sensor, the heating
is switched off (Attention to the risk of
frost!).
“PRESENT” mode: Your programmer
manages the regulation of your radiators
(Chauffage SMS is at rest). If your installation is
devoid of a heating programmer, the control is
managed by your heater.
“ECO” mode: Chauffage SMS manages the
control of your radiators from the temperature
setpoint defined by SMS. In the absence of a
temperature sensor, the heating is switched off
(Attention to the risk of frost!).
For recent boilers Chauffage S S acts
directly on a dedicated input. For others it
only acts on the water circulator of the
heating circuit.
Refer to wiring diagram on page 7 Refer to wiring diagram on page 8 Refer to wiring diagram on page 9