Skipper SB-100-SA Manuale utente

SKIPPER Electronics AS
Enebakkveien 150
P. O. Box 151, Manglerud
0612 Oslo, Norway
www.skipper.no
Telephone: +47 23 30 22 70
E-mail: support@skipper.no Document no: DM-BSB100 Rev 2012
Edition: 12.08.2020
100mm
Single bottom sea valve
Installation and operation Manual
SB-100-SA
SB-100-SB

Page2 of 22 Date: 12.08.2020
SKIPPER Electronics AS SB-100-XX Operation and Installation Manual
Weitergabe sowie vervielfältigung dieser unterlage, verwertung
und mitteilung ihres inhaltes nicht gestattet, soweit nicht
ausdrücklich zugestanden. Zuwiderhandlungen verpichten zu
schadenersatz.
Toute communication ou reproduction de ce document,
toute exploitation ou communication de ou son contenu sont
interdites, sauf autorisation expresse. Tout manquement à
cette règle est illicite et expose son auteur au versement de
dommeges et intèrèts.
Copying of this document, and giving it to others and the use
or communication of contents thereof, are forbidden without
express authority. Oenders are liable to the payment of
damages.
Sin nuestra expresa autorización, queda terminantemente
prohibida la reproducción total o parcial de este documento,
asì como su uso indebido y/o su exhibición o comunicación
a terceros. De los infractores Se exigirá el correspondiente
resarcimiento de daños y perjuicios.

Page3 of 22
Date: 12.08.2020
Contents
1. INTRODUCTION........................................................................................................................4
2. SPACE CONSIDERATIONS.....................................................................................................6
Space consideration SB-100-SA...................................................................... 6
Space consideration SB-100-SB ...................................................................... 7
3. WELDING THE BOTTOM FLANGE.....................................................................................8
4. SEA VALVE ASSEMBLY. ..........................................................................................................9
Assembly SB-100-SA...................................................................................... 9
Assembly SB-100-SB .................................................................................... 10
5. ASSEMBLING OF EXTENSION TUBE AND SENSOR ...................................................11
6. SENSOR INSTALLATION......................................................................................................12
7. CLAMP UNIT MOUNTING....................................................................................................13
8. LOWER THE SENSOR............................................................................................................14
Lowering sensor in SB-100-SB ..................................................................... 14
Lowering sensor in SB-100-SA ..................................................................... 14
9. SENSOR FORWARD ORIENTATION .................................................................................15
10. FINAL ASSEMBLY .................................................................................................................16
11. SENSOR REMOVAL...............................................................................................................17
12. RE-INSTALLATION...............................................................................................................18
13. ILLUSTRATED PARTS LIST. SHIPMENT ......................................................................19
12. ILLUSTRATED PARTS LIST. ASSAMBLED...................................................................20
Part list SB-100-SA........................................................................................ 20
Part list SB-100-SB........................................................................................ 21
13. MAINTENANCE .....................................................................................................................22
Maintenance Tasks for inactive sensors......................................................... 22
Dry docking in temperatures below freezing point........................................ 22
SKIPPER Electronics AS
SB-100-XX Operation and Installation Manual

Page4 of 22 Date: 12.08.2020
SKIPPER SB (Single Bottom) Sea Valve 100 mm
The SKIPPER SB Sea Valve 100 mm is used for installation of: SKIPPER speed log sensors and echo
sounder transducers tted with adaptors for XB-100-XX
1. Echo Sounder transducer type (50, 200 and 50/200 kHz).
2. Speed log sensors: DL2, DL21, DL1, DL850(270kHz), EML224.
Caution!
Be aware that the Sea Valve contains high precision parts and therefore proper
handling when mounting is essential for the nal result.
When handling the Sea Valve, all lifting devices must be attached on the outside of the
valve. It is very important to not insert any chains, wire, rope or any other device into
the valve chamber. This to avoid damaging and any kind of pollution of the Sea Valve.
The SKIPPER SB Sea Valve 100 mm is delivered partly assembled for transport. The parts necessary for
nal assembly will be found packed in a box delivered with the Sea Valve. First of all, it must be decided
where the Sea Valve should be installed. Normally, this will be in the fore part of the ship, in the centerline,
or as close to the centerline as possible. Optimal system operation is achieved by tting the transducer/
sensor as deep as possible on the hull.
• The active surface of the sensor must be installed with front face a maximum of +/-1 degree to the ships
horizontal plane. (2 axis Speed Logs).
• The active surface of the transducer must be installed with front face a maximum of +/-7 degree to the
ships horizontal plane. (Echo Sounder).
Do not mount transducers close to the bow thruster propeller outlets, or aft of other hull installations (outlets,
vents or other protruding details) who may create aeration or turbulence.
It is necessary to select a part of the hull that is submerged and free from turbulence and aeration under all
load and speed conditions, and to avoid positions where air is trapped in heavy weather.
If a at, horizontal section is not available for transducer tting, the shipyard must construct a suitable bed.
Welding seams in this area should be smoothed and rounded o, in order not to create turbulence or aeration
at speed.
Protect the active element of the transducer/sensors during transport and installation, and
do not paint the surface.
The Sea Valve should be placed in a service accessible place, large enough for installation and disassembly
of the sensor unit. See drawing: “Space considerations”.
1. INTRODUCTION
SKIPPER Electronics AS SB-100-XX Operation and Installation Manual

Page5 of 22
Date: 12.08.2020
Important
”Sensors for Speed Log and Echo Sounder are delivered with a xed cable. Attention must be taken
to allow easy replacement/pulling of new cable during maintenance”.
SKIPPER Electronics AS will recommend installation positions if GA-drawings (General
arrangements), lines drawings and frame drawings are made available for study.
Condition.
The welding to hull structures and structural support of the items may be subject to separate approval by
classication societies for each installation on board a ship.
Note: All “Item numbers” references on the following pages, can be found on drawing “Illustrated parts list.
Assembled” (unless specied).
SKIPPER Electronics AS
SB-100-XX Operation and Installation Manual

Page6 of 22 Date: 12.08.2020
2. SPACE CONSIDERATIONS
The Sea Valve should be placed in a service accessible place, large enough for installation and disassembly
of the sensor unit.
Space consideration SB-100-SA
SKIPPER Electronics AS SB-100-XX Operation and Installation Manual

Page7 of 22
Date: 12.08.2020
Space consideration SB-100-SB
SKIPPER Electronics AS
SB-100-XX Operation and Installation Manual

Page8 of 22 Date: 12.08.2020
Welding the Bottom Flange in Ship`s Hull
8
3. WELDING THE BOTTOM FLANGE
• When the position has been decided, a hole for the 220 mm bottom ange is cut in the hull.
• The bottom ange, Item (1), is welded into the hull. Standard welding practice, methods and procedures
should be observed, but may vary. (See welding notes).
Attention:
The bottom ange is a part of the Sea Valve that is machined with high accuracy and it should be
protected after mounting to avoid damage to the bottom ange surfaces. This to avoid leakage. If the
valve is pre-mounted, be sure to protect the valve from being polluted by welding debris.
WELDING NOTES!
All bottom parts and anges for welding are precisely machined parts. During welding of these parts
to the ship’s hull plates, careful attention must be paid to avoid construction strain on the bottom
parts and anges.
• Let parts cool down during welding.
• Over heating may change t and form and result in non-conformity with intended sensor/
transducer.
• Welding to thick hull steel plates will exert high stress on bottom parts and anges.
• Especially care must be taken during welding of stainless steel anges.
• Work must be performed by a qualied and certied welder.
Welding the bottom ange in ship’s hull.
SKIPPER Electronics AS SB-100-XX Operation and Installation Manual

Page9 of 22
Date: 12.08.2020
4. SEA VALVE ASSEMBLY.
• Place 1.5 mm gasket, Item (18) on top of Bottom Flange, Item (1).
• Then place the Main element, Item (6) on top of the Bottom Flange. The 16 mm nuts and washers should
be mounted and tightened. (Align parts before tighten nuts).
• Place a 1.5 mm gasket (item 18) on top of the main element, Item (6).
• Mount the intermediate element, Item (15) on top of the main element.
• All 8 screws, nuts and washers should be mounted, and tightened. (Align parts before tighten nuts).
Assembly SB-100-SA
Caution must be taken when mounting seavalves that all parts are aligned correctly, and that the inside is
clean. DO NOT use liguid sealants, and DO NOT paint the inside of a valve.
SKIPPER Electronics AS
SB-100-XX Operation and Installation Manual

Page10 of 22 Date: 12.08.2020
Step 1
• Place 1.5 mm gasket, on top of Bottom Flange.
• Then place the Ball Valve element on top of the Bottom Flange. The 16 mm nuts and washers should be
mounted, not tightened.
• Place a 1.5 mm gasket on top of the Ball Valve element.
• Mount the intermediate element on top of the Ball Valve element. The track for o-ring to be upwards.
• All 8 nuts and washers should be mounted, not tightened.
Step 2
• Place the plastic alignment tube, all the way, into the sea valve.
• Tighten 8 nuts ball valve to bottom ange.
• Tighten 8 nuts Intermediate element to ball valve.
• Remove the plastic alignment tool.
Step 1 Step 2
Intermediate element
Ball valve
Plastic alignment tube
Bottom ange
Assembly SB-100-SB
SKIPPER Electronics AS SB-100-XX Operation and Installation Manual
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Skipper Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente