socomec DIRIS A40 Manuale utente

DIRIS A40/A41
ETHERNET®
Operating instructions
F GB D I NL E P

2DIRIS A40/A41 - Ref.: 536 181 B GB

3
DIRIS A40/A41 - Ref.: 536 181 B GB
PRELIMINARY OPERATIONS _________________________________________________________ 4
GENERAL INFORMATION_________________________________________________________ 4
INSTALLATION __________________________________________________________________________ 5
CONNECTION _____________________________________________________________________ 5
VISUAL DIAGNOSTIC _____________________________________________________________ 6
PROGRAMMING ________________________________________________________________________ 7
ETHERNET CONFIGURATION ON DIRIS A40/A41_______________________________ 7
IP ADDRESS _______________________________________________________________________ 8
MASK _____________________________________________________________________________11
GATEWAY _________________________________________________________________________11
DHCP _____________________________________________________________________________12
WEBSERVER _____________________________________________________________________13
ENVIRONMENTAL CONDITIONS AND TYPE OF TEST _________________________14
INTERFACE SPECIFICATIONS: SUPPLY ________________________________________14
RS485 _____________________________________________________________________________14
ETHERNET________________________________________________________________________14
COMMUNICATION_____________________________________________________________________15
A : NEW COMMUNICATION TABLE FROM 01/2009__________________________ 15
1 > TABLE C550 Hex : Main measurements allocated from current transformer
and voltage transformer values__________________________________________ 15
2 > TABLE C650 Hex : Energy monitoring _____________________________________ 16
3 > TABLE C750 Hex : Additional measurements allocated from current transformer
and voltage transformer values__________________________________________ 16
4 > TABLE C850 Hex : Main measurements not allocated from current transformer
and voltage transformer values__________________________________________ 17
5 > TABLE C900Hex : Temperature measurements ______________________________ 18
6 > TABLE C950Hex : Harmonics___________________________________________ 18
7>TABLEE000Hex:Primaryconguration___________________________________ 24
8>TABLEE110Hex:Ethernetconguration __________________________________ 24
9>TABLEE200Hex:Ethernetconguration __________________________________ 26
Contents
GB

DIRIS A40/A41 - RS485 - ETHERNET®
4DIRIS A40/A41 - Ref.: 536 181 B GB
PRELIMINARY OPERATIONS
•ETHERNET MODULE WITH MODBUS RTU
GATEWAY – Ref. 48250204:
> MODBUS master gateway with RS485 3-point link
with TCP.
> MODBUS TCP and MODBUS RTU protocols.
>WEB-serverforproductconguration,displaying
the values and the diagnostics.
The gateway in this version enables the module to be
used as a master gateway for a Jbus/Modbus network
onRS485withamaximumof246slaves.Todothis,
a Jbus/Modbus address other than 255 needs to be
congured.
For personnel and product safety please read the
contents of these operating instructions carefully
before connecting.
Check the following points as soon as you receive the
DIRIS A40/A41 package:
•thepackingisingoodcondition,
•theproducthasnotbeendamagedduringtransit,
•the product reference number conforms to your
order,
•thepackagecontainstheproductandtheoperating
instructions.
Functions
The optional Ethernet module is linked to the DIRIS A40/A41(ref.48250201,48250202,48250207,48251201,
48251202,4825U201,48250211,48250213,48250214)andenablesconnectionstobemadetoa10BaseT
or 100BaseT type network. It also enables the DIRIS measurement units to be used and monitored from a PC
or an API.
GENERAL INFORMATION
The module is available in 2 versions:
•ETHERNET MODULE – Ref. 48250203:
> Link to an RJ45 connection.
> MODBUS TCP or MODBUS RTU Protocol with TCP.
>WEB-serverforproductconguration,displayingthe
values and diagnostics.
TCP/IP
Ethernet
Module
DIRIS A40/41
@1
(maximum of 4 clients)
Client 1
PC
Client 2
API
(maximum of 4 clients)
TCP/IP
(RJ45)
MODBUS
(RS485)
Ethernet
Module
DIRIS A40/41
@1
Client 1
PC
Client 2
API
Module
RS485
DIRIS A40/41
@2
Module
RS485
DIRIS A40/41
@3
Maximum of 246 slaves

DIRIS A40/A41 - RS485 - ETHERNET®
5
DIRIS A40/A41 - Ref.: 536 181 B GB
GB
INSTALLATION
CONNECTION
4
Follow indications when connecting the termi-
nal. Switch on voltage supply.
The DIRIS A40/A41 must be switched off
DIRIS 342 A
1
DIRIS 343 A
2
Fix the module in one of the four positions.
DIRIS 347 A
3
ThemoduleisttedontothebackoftheDIRIS A40/A41 in one of the 4 positions provided.
DIRIS 347 A

DIRIS A40/A41 - RS485 - ETHERNET®
6DIRIS A40/A41 - Ref.: 536 181 B GB
VISUAL DIAGNOSTIC
INSTALLATION
LED Colour Status Description
SYS - NOT LIT No internal electrical supply
Firmware is re-initialising
Hardware is faulty
Yellow LIT Loadingphaseofthesoftware,
waiting to start
FLASHING AT 1Hz Error during the start-up phase
Green LIT Operating system functioning
COM Red NOT LIT No errors
FLASHING Not used
LIT Internal JBUS error
Green NOT LIT See red LED
FLASHING JBUS external error
LIT Noerror,fullyfunctional
Link Green NOT LIT No connection to the Ethernet network
LIT Ethernet Network connected
Activity Yellow FLASHING Sending/receiving Ethernet frames
>
LED indicators

DIRIS A40/A41 - RS485 -
ETHERNET®
7
DIRIS A40/A41 - Ref.: 536 181 B GB
GB
PROGRAMMING
ETHERNET CONFIGURATION ON DIRIS A40/A41
This involves setting up the IP parameters for the
DIRIS connected to the gateway
IP address (Rth Adr IP) :
[CLASS A].[CLASS B].[CLASS C].[CLASS D]
Subnet mask (Eth MASH) :
[CLASS A].[CLASS B].[CLASS C].[CLASS D]
Gateway (Eth GATE) :
[CLASS A].[CLASS B].[CLASS C].[CLASS D]
DHCP activation (Eth DHCP) : Yes/ No
The factory setting is:
• IP address: 192.168.1.1
• Subnet mask: 255.255.255.0
• Gateway: 0.0.0.0
• DHCP activation: NO
x 4
x 4
x 4
x 1

DIRIS A40/A41 - RS485 - ETHERNET®
8DIRIS A40/A41 - Ref.: 536 181 B GB
PROGRAMMING
ADRESSE IP :
>
For example: Programming the address 191.158.1.7
CLASS A = 191
x 1
x 3
x 1

DIRIS A40/A41 - RS485 -
ETHERNET®
9
DIRIS A40/A41 - Ref.: 536 181 B GB
GB
ADRESSE IP :
>
For example: Programming the address 191.158.1.7
CLASS D = 158
PROGRAMMING
x 2
x 1
x 1

DIRIS A40/A41 - RS485 - ETHERNET®
10 DIRIS A40/A41 - Ref.: 536 181 B GB
PROGRAMMING
ADRESSE IP :
>
For example: Programming the address 191.158.1.7
CLASS C = 1
x 6
>
For example: Programming the address 191.158.1.7
CLASS C = 7
x 3
x 3
x 1
Altri manuali per DIRIS A40
14
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali socomec Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente