Quick Guide RS485 Frame Builder 08/2011 10
RS485 Frame Builder
• Standard messages supported by the RS485 RTS Transmitter
Read error counter of the stack
√GET_NETWORK_ERROR_STAT4D
55
45
74
4C
5E
4E
51
41
40
Message’s
number
Write label of the node
√SET_NODE_LABEL
Read label of the node
√GET_NODE_LABEL
Read version of the software
√GET_NODE_APP_VERSION
Read serial number of the node
√GET_NODE_SERIAL_NUMBER
Configure and reset network communication
statistics
√SET_NETWORK_STAT
Request to send network communication statistics
√GET_NETWORK_STAT
Define one entry in the group address table
√SET_GROUP_ADDR
Read one entry of groups table
√GET_GROUP_ADDR
Ask all online nodes to send their NodeID
√GET_NODE_ADDRESS
Message’s descriptionCompatibilityMessage’s name
RS485 Frame Builder
/ RS485 RTS Transmitter
• Settings messages supported by the RS485 RTS Transmitter
Set the modes to use√
SET_CHANNEL_MODE90
Set the number of RTS frames the product should
send on a CTRL_TILT order
√
SET_TILT_FRAMECOUNT91
Set the number of RTS frames the product should
send on a CTRL_DIM order
√
SET_DIM_FRAMECOUNT92
Activate Deactivate the sun protection√
SET_SUN_AUTO93
Lock Unlock Dry Contact inputs√
SET_DCT_LOCK94
Validate an addition or a deletion of an RTS
channel’s address
√
SET_CHANNEL97
9A
98
Message’s
number
Record Delete Intermediate Position√
SET_IP
Open the programming mode of a receiver√
SET_OPEN_PROG
Message’s descriptionCompatibilityMessage’s name