Sona WTSL-SN-1 Manuale utente

1
Installation and User Guide
For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2®
"sona control unit install"

2
Sprue Safety Products Ltd. Vanguard Centre, Coventry CV4 7EZ UK
A Sprue Brand
GN3019R2
Email: technicalsupport@sonasafety.com / Web: www.sonasafety.com
Technical Support Line: 0800 171 2009
PLEASE READ THIS GUIDE IN FULL BEFORE USING YOUR WTSL-SN-1 ALARM
CONTROL UNIT!
This user guide is also available in large text and other formats. Please
call 0800 171 2009 for further information.
Battery powered Alarm Control Unit with Test, Silence, Locate function. Non-replaceable 3V
DC battery.
W2 module contained within product independently tested to RF standard ETSI EN 300 220-2 V2.3.2
(2010-02) byTRaC Global Ltd.

3
Features . . . . . . . . . . . . . . . . 4
Positioning . . . . . . . . . . . . . . 6
Installation. . . . . . . . . . . . . . . 6
Wireless Interlink . . . . . . . . . . . 8
Making the Alarm Control Unit
Tamper Proof . . . . . . . . . . . . .10
INSTALLATION GUIDE
Testing the Alarm System . . . . . .12
Product Functionality . . . . . . . . .13
When an Alarm Sounds . . . . . . .17
LED Indicators. . . . . . . . . . . . .18
Troubleshooting. . . . . . . . . . . .20
Maintenance. . . . . . . . . . . . . .21
Disposal . . . . . . . . . . . . . . . .22
Warranty . . . . . . . . . . . . . . . .23
USER GUIDE

4
FEATURES
• Wi-Safe 2®technology, enabling wireless interlinking between other Wi-Safe 2 products.
• Test / Silence ( ) button, allowing you to regularly test all wirelessly interlinked alarms on
a network. Pressing the silence button will reduce the sensitivity of alarms for up to 10 minutes,
unless carbon monoxide has been detected, in which case you can use the 'Locate' function below
to find the source alarm.
• Locate button ( ), allowing you to silence all alarms but the initiating alarm, during an alarm
condition. During a fault condition, this feature will allow you to locate the alarm in fault, in a
similar way.
• 5 year warranty.
INSTALLATION GUIDE

5
Test / Silence button Locate button
Carbon monoxide
alarm indicator Smoke / Heat
alarm indicator
Fault indicator

6
POSITIONING
This Alarm Control Unit is suitable for use in domestic premises only. It should be installed at an
accessible point on the wall, in a location where it will not be accidentally operated or knocked. The
Alarm Control Unit should be installed at a distance of approximately 1.4 m from the floor, lower if
required, so that it is fully accessible.
INSTALLATION
• Ensure this Alarm Control Unit is installed by a competent person who feels able to install it
according to the instructions.
• Read all installation instructions prior to installing this product.
WARNING:To prevent injury, thisAlarm Control Unit must be securely attached to the wall in accordance
with the installation instructions.
To mount the bracket onto a wall:
Please ensure that you use the screws provided, as they were chosen specifically for use with this
product. Drill holes into the wall and insert suitable wall plugs. Screw the bracket in place.

7
ACTIVATING THE ALARM CONTROL UNIT
The Alarm Control Unit has a sealed-in non-
replaceable battery. To activate the control unit
remove the disabling clip.
Upon activating the control unit all three LED's
should simultaneously flash twice, to indicate
that they are working.
Once the alarm is activated it is at this stage you
will need to connect it into the wireless network,
before securing to the wall bracket.

8
WIRELESS INTERLINK
The Alarm Control Unit is designed to be used as a remote interface between up to 50 products within
the Wi-Safe 2 product range.The Alarm Control Unit can be used to test, silence or locate any alarms
on the Wi-Safe 2 network. It is not designed to communicate with wireless alarms from other ranges
or manufacturers. The control unit needs to be ‘learned-in’ or interlinked, in order to communicate
within the network.
Wi-Safe2 enables wireless communication with any other product with Wi-Safe2 technology inside.
When one alarm detects smoke / heat / carbon monoxide, the wireless module inside sends a wireless
signal to all the connected alarms, ensuring almost instantaneous reaction across the network.
Wireless Interlink
Wi-Safe 2
enabled device
Wi-Safe 2
Test, Silence,
Locate Unit

9
Learn button
LED
HOW TO ‘LEARN-IN’ THE ALARM CONTROL
UNIT TO A WIRELESS NETWORK:
1. Using a ballpoint pen, briefly push and
release the 'learn button' on the back of the
control unit.The red LED next to the learn
button will flash briefly then light up for
approximately 5 seconds.
2. During these 5 seconds you need to briefly
press the test button on an alarm already
in the network, to wirelessly interlink the
two. The alarm will give an audible sound
consisting of two cycles of three loud beeps.
3. The red LED on the back of the control
unit will flash to indicate that it has been
‘learned-in’ successfully. If the test button
is not pressed quickly enough, the ‘learn-
in’ process will fail. If this happens, repeat
the process.

10
4. To complete the installation simply slide the
control unit onto the bracket until it clicks
into place.The control unit is now part of the
whole network.
The method above assumes you have already
installed your alarm network, prior to installing
your Alarm Control Unit. If you want to install
your Alarm Control Unit first, you can learn your
smoke, heat and CO alarm into it by following
the instructions in your alarm manual, using the
Alarm Control Unit as alarm 1 and holding the
Test button of the Alarm Control Unit for at least
2 seconds.
MAKING THE ALARM
CONTROL UNIT TAMPER
PROOF
Do not complete this action until you have
wirelessly interlinked all of your alarms.
Indice
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente