suprema IM-120 Manuale utente

Input Module
INSTALLATION GUIDE
Version 1.00
English
EN 101.00.IM-120 V1.00A

CONTENTS
Safety information 2
Instructional icons 2
Introduction 4
Components 4
Accessory 5
Name and function of each part 6
Installation 8
Power Connection 8
RS-485 Connection 9
Relay Connection 10
Supervised Input Connection 11
Tamper Connection 12
Using the Input Module with the enclosure 12
Product Specifications 17
FCC compliance information 19
Appendices 20
Disclaimers 20
Copyright Notice 20
Open Source License 20
MIT Open Source License 21

2
Safety information
Safety information
Please read this safety instructions before you use the product to prevent injury to yourself and others and to prevent
property damage. The term 'product' in this manual refers to the product and any items provided with the product.
Instructional icons
Warning: This symbol indicates situations that could result in death or severe injury.
Caution: This symbol indicates situations that may result in moderate injury or property damage.
Note: This symbol indicates notes or additional information.
Warning
Installation
Do not install or repair the product arbitrarily.
• This may result in electric shock, fire, or product damage.
• Damages caused by any modifications or failure to follow installation instructions can void the manufacturer’s warranty.
Do not install the product in a place with direct sunlight, moisture, dust, soot, or a gas leak.
• This may result in electric shock or fire.
Do not install the product in a location with heat from an electric heater.
• This may result in fire due to overheating.
Install the product in a dry location.
• Humidity and liquids may result in electric shock or product damage.
Do not install the product in a location where it will be affected by radio frequencies.
• This may result in fire or product damage.
Operation
Keep the product dry.
• Humidity and liquids may result in electric shock, fire, or product damage.
Do not use damaged power supply adaptors, plugs, or loose electrical sockets.
• Unsecured connections may cause electric shock or fire.
Do not bend or damage the power cord.
• This may result in electric shock or fire.

3
Safety information
Caution
Installation
Do not install the product under direct sunlight or UV light.
• This may result in product damage, malfunction, discoloration, or deformation.
Do not install the power supply cable in a location where people pass by.
• This may result in injury or product damage.
Do not install the product near magnetic objects, such as a magnet, TV, monitor (especially CRT), or speaker.
• The product may malfunction.
Operation
Do not drop the product or cause impacts to the product.
• The product may malfunction.
Do not disconnect the power supply while upgrading the firmware of the product.
• The product may malfunction.
Do not press buttons on the product by force or do not press them with a sharp tool.
• The product may malfunction.
Do not store your product in very hot or very cold places. It is recommended to use the product at
temperatures from -20°C to 60°C.
• The product may malfunction.
When cleaning the product, mind the following.
• Wipe the product with a clean and dry towel.
• If you need to sanitize the product, moisten the cloth or the wipe with a proper amount of rubbing alcohol and gently
clean all exposed surfaces including the fingerprint sensor. Use rubbing alcohol (containing 70% Isopropyl alcohol) and a
clean, non-abrasive cloth like lens wipe.
• Do not apply liquid directly to the surface of the product.
Do not use the product for anything other than its intended use.
• The product may malfunction.

4
Introduction
Introduction
Components
190
160
80
90
80
IM-120
Input Module
(IM-120) Drilling Template
Input Module
201.00.IM-120 V1.00A Open Source Software
MIT License
306.01 V1.02A
E
Fixing screw x12 Spacer x6 Quick Guide Open Source Software
Guide
• Components may vary according to the installation environment.

5
Introduction
Accessory
You can use the Input Module with the enclosure (ENCR-10). The enclosure is sold separately, and you can install two
Input Modules in one enclosure. The enclosure includes a power status LED board, power distribution board, power
supply, and tamper. To learn how to install the Input Module in the enclosure, refer to Using the Input Module with the
enclosure.
• There is no optimal height for installing ENCR-10 on the wall. Install it to a safe and convenient location for you
to use.
• Fixing screws for the enclosure, the device, and the power supply cable are included in the ENCR-10 package.
Use each screw correctly by following the details below.
- Fixing screws for the enclosure (diameter: 4 mm, length: 25 mm) x 4
- Fixing screws for the device (diameter: 3 mm, length: 5 mm) x 6
- Fixing screws for the power supply cable (diameter: 3 mm, length: 8 mm) x 1
ENCR-10

6
Introduction
Name and function of each part
5
No. Name
1RESET button
2INIT button
3Supervised Input (9, 10, 11) connection
4Supervised Input (6, 7, 8) connection
5Relay 1 connection
6AUX IN (0, 1) and Tamper connection
7RS-485 terminating resistance switch
8RS-485 connection
9Power connection (DC 12 - 24 V)
10 Relay 0 connection
11 Supervised Input (3, 4, 5) connection
12 Supervised Input (0, 1, 2) connection
• Press and hold the INIT button for 2 seconds or longer to initialize the Input Module currently linked with a
device and connect it to a different device.
12
3
4
5
6
7
8
10
9
11
12

7
Introduction
LED Indicator
You can check the status of the device by the color of the LED indicator.
Item LED Status
POWER Solid red Power on
STATUS
Solid green Connected with the secure session
Solid blue Disconnected from a master device
Solid pink Upgrading the firmware
Solid yellow RS-485 communication error due to different encryption key or OSDP
packet loss
Solid sky blue Connected without the secure session
Blinking green Waiting for the final input to reset settings
Solid green Settings initialization completed
SUPERVISED INPUT (0 - 11) Solid red Receiving an input signal
RELAY (0, 1) Solid red Relay operation
RS-485 TX Blinking orange Transmitting RS-485 data
RS-485 RX Blinking green Receiving RS-485 data
AUX IN (0, 1) Solid orange Receiving an AUX signal
TAMPER Solid orange Tamper operation
Installation example
The Input Module provides instant relay behavior by connecting to BioStar 2 for detected inputs in real-time and it
operates a relay or saves logs for detected inputs while it is disconnected from the master device. The Input Module
supports 12 channel supervised input, 2 channel relay, 2 channel AUX input, and 1 channel tamper input to detect
status, such as 1 channel RS-485, disconnection, short, on, or off for networking with the master device.
Fire
Alarm
Emergency
Door Sensor
Input
Input
Input
Input
Relay
Relay Alarm
RS-485
TCP/IP
Master Device
BioStar 2
Sensor
Sensor
Smoke
Sensor

8
Installation
Installation
• To learn how to install the Input Module in the enclosure, refer to Using the Input Module with the enclosure.
1
Fix a spacer on the position to mount Input Module using a fixing screw.
2
Fix the product on top of the fixed spacer firmly using a fixing screw.
Power Connection
DC Power
• Make sure to use separate power for the access control device and Input Module.
• Use the correct power specifications (12 VDC, 130 mA or 24 VDC, 82 mA).
• It is recommended to connect and use an Uninterruptible Power Supply (UPS) to prevent power failure.
12 VDC or 24 VDC
GND

9
Installation
RS-485 Connection
You can connect the Input Module to a master device.
• Use an AWG24 twisted pair with less than 1.2 km in length for the RS-485 cable.
• If connecting with a RS-485 daisy chain, connect the termination resistor (120 Ω) to both ends of the daisy
chain connection. If connected to the middle line, the signal level becomes smaller and the communication
performance will deteriorate. Make sure to connect it to both ends of the daisy chain connection. Set the
termination switch(TERM) to ON for Input Module.
• RS485 wire size shall be over 26 AWG and all wiring must comply with National Electrical Code, ANSI/NFPA 70.
Master Device
Slave Device
Terminating
resistance switch
Slave Device
RS-485
TRX+
RS-485
TRX-
Terminating
resistance
(120Ω)
GND
Indice
Altri manuali suprema Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente