SLC-TRQ4 manual v1.1 6.
procedures with 2 discrete peaks as cap
release and warranty ring break torque
testing
testing hundreds of cycles
Result: maximum of the peaks
1. Select measuring unit
2. Set trigger level –Trigger level is a load level that starts and stops the
measurement recording - “start-stop signal” of the measurement. As long as the
measured value is under the trigger, recording will not be started. Measurement
will be stopped (or paused), if the measured value drops under the trigger level.
Recommended level is between 2-15% of the expected maximum value.
If you need range checking, set high and low limits. Values will be displayed with
different colors:
blue –under range
green –in range
red –over range
(by 2-channel unit select the “primary” channel too)
It is possible to switch on a sound signal for the exceeding of the high limit
with the ring button.
3. Set time out (relevant only in double peaks mode) –This time defines how long the
instrument waits for the start of the second peak’s measurement. If time out
elapses without value over the trigger, MAX2 will be 0.
4. Set Y scale for the diagram’s scaling (default setting is the maximum of the cell,
recommended value is a little above your expected maximum)
5. Select sample rate (6,25 –400 Hz, recommended: 50-200 Hz)
6. Set turn off time (for automatic shut down after disconnecting). For the TRQ3
displayed model it also means a standby time. If the touchscreen is not touched for
the set time interval, the device will automatically turn off.
7. Check Auto save box if you want to save all results automatically. The Android
application will also save those measurements, which were started on the
touchscreen of the TRQ3 (if the device is connected, and auto save is on).
CLEAR button on the main screen will clear the screen
CLEAR button on the SETUP screen will clear all the setup parameters including the
SmartLoadCell pairing.
Status LED –Status LED has 3 states:
-Green flashing –unit is ready to use, but unconnected
-Blue flashing –unit connected
-Red - charging
Menu/History –All saved results can be reviewed. Results can be deleted one by one (or
in bulk with hitting the trash button longer). Diagrams can be scrolled and zoomed.
Menu/Export to XML will create an export_11111_22222.xml file in the Download folder
of your android device. Download file can be forwarded to PC via Bluetooth, email,
internet or USB cable.