Svantek SV 111 Manuale utente

1
SV111 User Manual
USER MANUAL
SV 111
Warsaw, 2018-12-19
Rev. 01.02
Copyright © 2018 SVANTEK.
All rights reserved.

2
SV111
User
M
anual
Note: Because of continuous product improvement SVANTEK reserves the right to make
changes to product specifications without notice. To download the most up to date user's
manual please visit our web site at www.svantek.com. This user’s manual presents the
firmware revision named 1.16.1.
The succeeding software revisions (marked with the higher numbers) can change the view of
some displays presented in the text of the manual.
WEEE Notice: Do not throw the device away with the unsorted municipal waste at the end
of its life. Instead, hand it in at an official collection point for recycling. By doing this you will help to
preserve the environment.
The software described in this manual is furnished under a license agreement and may be used only
in accordance with the terms of that agreement.
Copyright Notice
Copyright © 2018 Svantek Sp. z o.o.
All rights reserved.
Reproduction without permission is prohibited.
Trademarks
Trademarks or registered marks in this manual belong to their respective manufacturers.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment
on the part of Svantek.
Svantek provides this document “as is”, without warranty of any kind, either expressed or implied,
including, but not limited to, its particular purpose. Svantek reserves the right to make improvements
and/or changes to this manual, or to the products and/or the programs described in this manual, at
any time.
Information provided in this manual is intended to be accurate and reliable. However, Svantek
assumes no responsibility for its use, or for any infringements on the rights of third parties that may
result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically
made to the information herein to correct such errors, and these changes are incorporated into new
editions of the publication.
Technical Support Contact Information:
web: www.svantek.com
e-mail: [email protected]om.pl

3
SV111 User Manual
CONTENTS
1. General safety summary ................................................................................................................. 4
2. Calibration ....................................................................................................................................... 5
3. Accuracy of calibration .................................................................................................................... 5
4. SV111 model information ............................................................................................................... 5
5. Unpacking and Inspecting the package contents ............................................................................ 6
6. Optional accessories ........................................................................................................................ 7
7. SV111 vibration calibrator ............................................................................................................... 8
8. Control panel ................................................................................................................................... 9
9. Operating diagram ........................................................................................................................ 10
10. Submenu diagram ..................................................................................................................... 11
11. Installation of the whole-body sensor....................................................................................... 12
12. Installation of the SV 105 Hand-Arm sensor ............................................................................. 14
13. Installation of the SV 3023M2 accelerometer .......................................................................... 16
14. Installation of the general-purpose accelerometer .................................................................. 16
15. Programming ............................................................................................................................. 17
16. General Care and Cleaning ........................................................................................................ 19
17. Technical data............................................................................................................................ 20
Appendix A Recalibration ................................................................................................................ 21
Appendix B Defining calibration coefficient ................................................................................... 24

4
SV111
User
M
anual
1. General safety summary
Review the following safety precautions to avoid injury and prevent from damaging
this product or other products connected with it. To avoid potential hazards, use this
product only as specified. Qualified personnel should only perform the service
procedures.
Warnings, precautions and maintenance:
Before using the calibrator be sure that the shaker shipping lock is detached. Starting
the vibration calibrator with the shipping lock may destroy it.
Use a proper AC/DC adapter, specified for this product and certified for the country
of its use.
Keep the product’s surfaces clean and dry.
Even when the device is not in use it is recommended to charge the battery once a
month to keep it in good condition.
It is recommended to carry out a technical inspection and recalibration of the device
every 12 months to ensure accurate calibration level.
Recalibration can be made by the calibration laboratory. If there is no possibility to
recalibrate the device by calibration laboratory the device should be send to the
manufacturer.
All maintenance work and repairs can only be done by the personnel trained by the
manufacturer.
Handle with care.
Safety terms and symbols:
Symbol Symbol meaning
Do not throw into standard municipal waste containers. The user is obliged to
deliver used equipment to the manufacturer or to the recycling collection point.
This product can be recycled
This product has met EU consumer safety, health or environmental requirements

5
SV111 User Manual
2. Calibration
One of the fundamental questions, that are most frequently asked while taking a
measurement, is whether its result is accurate. Proceeding, with a measurement without
having a positive answer to this question, may result in obtaining data of no practical use
and wasting our time. However, we may easily obtain the answer by performing a calibration
of the vibration level meter using a vibration calibrator. This device should be used before
every set of measurements.
The vibration calibrator is a device, which produces the vibration of the defined levels and
frequency. It allows to calibrate the vibration meter in comparative way.
Calibration procedure is also the best way for the complete measuring system (Meter, Cable
and Transducer connected together) check. This is an essential action for the reliable
measurements performed in the field!
3. Accuracy of calibration
Each measurement performed by any measurement device is burdened with an error. Result
obtained from such measurement is only an estimate of the real value of the measured
quantity. Hence, the purpose of calibration is to limit this inevitable error to a certain
acceptable level. Maximum absolute value of the error of generated vibration signals is
called the tolerance and is strictly defined by the standard ISO8041:2005.
4. SV111 model information
The model SV111 is a Portable Vibration Calibrator. It is designed to check/calibrate various
types of vibration level meters according to the ISO 8041:2005.
Three standard frequencies 15.92 Hz, 79.58 and 159.2 Hz (plus one more extra 636,6Hz)
combined with high loading mass brings opportunity to calibrate almost any existing
transducer.
Because of its dedicated adapters, SV111 allows to take measurements in three directions.
So, to calibrate effectively tri-axial transducers!
Because of its own internal rechargeable battery, it is a truly mobile and flexible device
designed to use either in a laboratory or during fieldwork.
The unique feature of SV111 is capability to calibrate complete “seat accelerometer”,
without necessity to extract accelerometer form the rubber cushion!
The robust case allows placing the calibrator directly on the ground, what is extremely useful
in the field applications. Built in electronic leveling system helps with correct positioning of
the device for correct vibration calibration. Leveling of the SV111 is important for keeping
transversal vibrations levels within tolerances specified by the ISO8041:2005.

6
SV111
User
M
anual
5. Unpacking and Inspecting the package contents
Despite careful packing, the risk of the device damage cannot be entirely eliminated. Upon
delivery, please make sure that the device is not damaged and verify that you received the
ordered equipment and optional accessories (if ordered). In case of any problems, please
contact an authorized Svantek representative, the service staff or the manufacturer directly.
The complete set includes the following items:
SV111 Vibration calibrator
SA 33 AC/DC adapter
Before using the device:
Be sure that the shaker shipping lock is detached. Starting the vibration calibrator
with the shipping lock may destroy it.
To detach the shaker shipping lock, unscrew four bolts with the hex wrench and two screwdriver
tips attached to the magnet. Screw the central bolt into the loose sleeve.
Don’t throw away the transport lock with three bolts because it is necessary to secure the shaker
during transportation.

7
SV111 User Manual
Charge SV111 to the full. In order to charge the battery, connect SA33 AC/DC adapter
plug to SV111 EXT_DC supply socket and then connect it to the mains.
The SA33 AC/DC adapter is placed in the charger slot.
If the device has been kept or transported in low temperature (below 0 °C), it is
recommended to leave it for a few hours in the room temperature before connecting
it to the power supply. If any steam condensation appears, it is recommended not to
connect the device to the mains electricity for 4 to 8 hours until the exterior surface
is dry.
6. Optional accessories
The SV111 calibrator set doesn’t include the SA105 adapter used for calibration of the
SV105B hand-arm transducers and the SA44 adapter for calibration of the SV 3023M2
transducers. These adapters are optional and should be ordered separately.

8
SV111
User
M
anual
7. SV111 vibration calibrator
SV111 vibration calibrator
1.Magnet with two screwdriver tips; 2.Adapter; 3.Hex wrench slot with support
sleeves; 4.Charger slot; 5.Shaker; 6.Transportation lock; 7.Support; 8.Fastening
screw; 9.Display; 10.Keyboard; 11.EXT_DC supply socket; 12.USB port;
1
2
3
4
5
7
8
9
10
11
12
6

9
SV111 User Manual
8. Control panel
SV111 control panel
1.Vibrations level button/Power on button A; 2.Start/Stop button; 3.Serial number
box; 4.Display box; 5.Vibration frequency button/Power button B; 6. Spirit level;
7.USB port
1
2
3
4
5
6
7

10
SV111
User
M
anual
9. Operating diagram
SV 111
l
evelling
Vibration
parameters
setting
menu
Shaker
vibration
SV 111 s
witching
on
Sensor
installation
Skip
ping
the levelling
SV 111 l
evell
ed
…
Sample vibration
Start
shaker
Stop
shaker
Vibrations
parameters not
reached properly
Shaker vibrates
with set
Altri manuali per SV 111
1
Indice
Altri manuali Svantek Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione