Tellabs FlexSym OLT-mini Manuale utente

Copyright ©2021 Tellabs®All Rights Reserved
FlexSym©OLT-mini Installation and Turnup Guide

FlexSym©OLT-mini Installation and Turnup Guide
Page 2 of 35
Tellabs®Information
Copyright
Copyright ©2021 Tellabs Enterprise, Inc. All rights reserved.
The information in this publication is proprietary to Tellabs Enterprise, Inc.
No part of this publication may be used, disclosed, reproduced, adapted, translated, stored in a
retrieval system, or transmitted in any form or by any means, electronic or mechanical, for any
purpose, without the written permission of Tellabs Enterprise, Inc. Although every precaution
has been taken in the preparation of this publication, Tellabs Enterprise, Inc. assumes no (i)
responsibility for errors or omissions contained herein or (ii) liability for any damages resulting
from the use of information contained herein. Information in this publication is subject to change
without notice.
Trademarks
The following trademarks and service marks are owned by Tellabs Operations, Inc. or its
affiliates in the United States and/or other countries: TELLABS®, TELLABS and T symbol®,
T symbol®.
Any other company or product names may be trademarks of their respective companies.
Proprietary
This document is the property of Tellabs Enterprise, Inc. and contains confidential and
proprietary information owned by Tellabs Enterprise, Inc. Any copying, use, or disclosure of the
contents of this document, without the written permission of Tellabs Enterprise, Inc., is strictly
prohibited.

FlexSym©OLT-mini Installation and Turnup Guide
Page 3 of 35
Table of Contents
Tellabs®Information ......................................................................................................... 2
Copyright.....................................................................................................................................2
Trademarks.................................................................................................................................2
Proprietary..................................................................................................................................2
Tellabs®FlexSym OLT-mini Installation and Turnup Guide........................................ 4
Description..................................................................................................................................5
Site Preparation..........................................................................................................................7
Safety Precautions...................................................................................................................10
Installation ................................................................................................................................12
OLT Turnup...............................................................................................................................19
Add OLT to Panorama PON....................................................................................................26
Add ONT....................................................................................................................................31
Contact Us ................................................................................................................................35

FlexSym©OLT-mini Installation and Turnup Guide
Page 4 of 35
Tellabs®FlexSym OLT-mini Installation and Turnup
Guide
This document provides instructions to install and turnup the Tellabs® FlexSym OLT-
mini optical line terminal.
Document Revisions
Revision
Date
Notes
Revision A
Jul 2021
•Initial Release of Document
Related Documentation
N/A

FlexSym©OLT-mini Installation and Turnup Guide
Page 5 of 35
Description
The Tellabs FlexSym® OLT-mini is a small line size outdoor OLT with industrial temp
ratings. This OLT is designed to be utilized for small installations without temperature
control.
The OLT-mini supports the following features:
•2x PON Ports: The OLT-mini supports 2x PON ports. The ports can be either GPON or
XGS-PON. The PON modes cannot be mixed.
•4x 10/1 SFP+ Ports: The OLT-mini supports 4x OLT PON ports, typically intended to be
daisy chained to support the full bandwidth either East or West in an RSTP Switched
ring. The OLT uplinks are totally non blocking and can deliver the full bandwidth of the
10G PONs upstream or downstream.
•μUSB Interface: The OLT-mini provides a μUSB interface for turnup and debugging. The
OLT-mini supports turnup via a copper Ethernet interface as well.
•Industrial Temp Rating: The OLT-mini comes with a weathertight enclosure which
supports an operating range of -40C to +55C.

FlexSym©OLT-mini Installation and Turnup Guide
Page 6 of 35
•AC or DC Powering Options: The OLT-mini can be installed with AC power or DC
power input options. Additionally dual AC or DC power inputs are supported for high
availability solutions.
•Wall Mount:Supports standard mounting bracket for mounting of the OLT-mini on
walls or backboards.
•SSHv2 CLI Interface: The standard Tellabs CLI interface is supported for turn up and
debugging of the unit.
•Standard Panorama PON Interface: The Tellabs Panorama PON software will manage
the OLT-mini using the standard GUI and web interfaces.

FlexSym©OLT-mini Installation and Turnup Guide
Page 7 of 35
Site Preparation
•Tools Required
•OLT Part Numbers for Ordering
•OLT Laser Part Numbers
•OLT-mini Power Requirements
•OLT-mini Environmental Specifications
Tools Required
Installation of the OLT-mini will require the following tools:
•Laptop Computer: A laptop computer is required for turnup of the OLT-mini and
proper configuration of the uplink interfaces.
•μUSB Cable: If connecting to the OLT-mini using the μUSB interface, you will
need a standard USB3 to μUSB cable. The OLT-mini has a built in μUSB to serial
converter, so nothing other than the cable is needed for turnup via this interface.
You will need a terminal program to access the serial interface of the OLT-mini if you
use the μUSB interface. Teraterm and putty are good open source options. Teraterm is
used for the examples in this document.
•Copper SFP Module: If connecting to the OLT-mini using SSHv2, you will need a
copper SFP module to install into one of the OLT uplink ports.
You will need an SSHv2 terminal program if using SSHv2 to access the CLI and
configure the OLT-mini Turnup parameters. Teraterm and putty are good open source
options.
•Power Wiring: If using DC wiring, 20 AWG wiring or better is recommended.
•Uplink Lasers: Ensure you have purchased the appropriate Tellabs supported
Modules shown in the "OLT Laser Part Numbers" table shown below.
•M6 or 7/32" Allen Wrench: The enclosure is opened using either an M6 or
7/32" Allen wrench.

FlexSym©OLT-mini Installation and Turnup Guide
Page 8 of 35
OLT Part Numbers for Ordering
OLT Mini Part
Numbers
OLT Description
Comments
81.11S-OLTM-AC
FlexSym® OLT-mini, 2 PON, 4 Uplink, 120V AC
powered, optional DC power
Redundant power supply. DC
input option.
OLT Laser Part Numbers
Laser modules for the PONs and Uplinks must be purchased seperately. The OLT-mini
comes equipped with no laser modules.
Both PON lasers in the OLT-mini must be of the same type, i.e. both GPON, or both
XGS-PON.
OLT Laser Part
Number
Laser Description
Distance
Connector
Comments
0410-0471
850nm 10G SR SFP+
400m MMF
2xLC
Short Range MMF 10G Laser
0410-0470
1310nm 10G LR SFP+
10km SMF
2xLC
Long Range 10km 10G Laser
128211
850nm 1G SX SFP
550m MMF
2xLC
Short Range 1G Laser
81.11T-S1GB40KM-R6
1310 1G LR SFP
40km SMF
2xLC
Long Range 1G Laser
C.11T-S1GBELX1131S
1310 1G LR SFP
10km SMF
2xLC
Long Range 1G Wideband Laser
C11T-S1GBER450030
Copper1G SFP
100m
RJ45
Copper 1G SFP
81.11T-XFPGPON-IT
Tellabs GPON Laser
20km
1xSC UPC(blue)
2.5/1.25G Bidi GPON Laser
81.11T-XFPXGSPON
Tellabs XGS-PON Laser
20km
1xSC UPC(blue)
10G/10G Bidi XGS-PON Laser

FlexSym©OLT-mini Installation and Turnup Guide
Page 9 of 35
OLT-mini Power Requirements
The OLT-mini has the following AC power requirements when powered by AC:
AC Power Specifications
Value
Comments
AC Input Voltage
100-240VAC
AC Input Line Frequency
50-60Hz (nominal)
AC Current Rating
.7 A @ 100VAC, .3 A @ 240VAC
Max AC Input Power
72 W
The OLT-mini has the following DC power requirements when powered by DC:
DC Power Specifications
Value
Comment
DC Input Voltage
43-57DC
DC Current Rating
1.2 A @ 54VDC
DC Power
65 W
OLT-mini Environmental Specifications
Environmental Specifications
Value
Comments
Dimensions
13.5 x 6.25 x 14 in (343 x 159 x 356 mm)
Certifications
Operating Temperature Range
-40C to +55C (-40F to 131F)
Operating Humidity
5 to 95% non condensing

FlexSym©OLT-mini Installation and Turnup Guide
Page 10 of 35
Safety Precautions
Product Disposal Symbol
The Waste Electrical and Electronic Equipment (WEEE) symbol will accompany specific
products that must be collected and disposed of separately from household waste. The
black bar under the symbol signifies the product was placed on the market after August
13, 2005.
Items such as integrated batteries can be disposed of along with the product; they will
be separated at recycling centers. By participating in the separate collection of identified
products, you will help with the correct disposal of these items and contribute to the
ongoing protection of our environment and human health.
Safety Precautions
•Read this manual, in its entirety, prior to installing the device.
•Observe all warnings and cautions mentioned in this manual.
•Keep the device dry, ventilated, and clean.
•During severe weather conditions, unplug all electrical connections to the device
to protect against lightning surges.
•Keep the ventilation openings clean to ensure proper airflow and prolong the life
of the device.
•Do not open the device. There are no user-serviceable parts in the device.
Indice
Altri manuali Tellabs Hardware di rete

Tellabs
Tellabs ONT180C Manuale utente

Tellabs
Tellabs 251 Manuale utente

Tellabs
Tellabs 100 Series Manuale utente

Tellabs
Tellabs 7100 Istruzioni operative e di manutenzione

Tellabs
Tellabs 263DC Manuale utente

Tellabs
Tellabs 6047 Manuale utente

Tellabs
Tellabs FlexSym ONT205 Manuale utente

Tellabs
Tellabs 8820 MSR Guida utente

Tellabs
Tellabs FlexSym OLT6 Manuale utente
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio