INS261-8 4/21
1.1 Introduction
The Premier Elite 60IXD expander module provides up to 60 zones of expansion
using iD biscuits. The module has two loops each supporting up to 30 iD biscuits.
The 60IXD module can be installed in one of two modes:
Local Mode
The local mode allows the 60IXD to be connected to the expansion port on the
Premier Elite 24/48/88/168/640 control panels. This mode provides the following
facilities:
Two loops each supporting up to 30 iD biscuits
Fused 12V output for powering detectors
Advanced diagnostics using the system remote keypad
Biscuits can be mapped to any zone in the system
N The 60IXD expander module is only supported on Premier Elite 88/168
control panels from version 5.0 onwards Premier Elite 24 from Version 10.0
onwards and Premier Elite 48 from version 2.0 onwards. The Premier Elite 48 can
only support a maximum of 48 zones/biscuits. The Premier Elite 24 can only
support 24 biscuits
Network Mode
The network mode allows the Premier 60IXD to be connected to the network
terminals of any Premier control panel. This mode provides the following facilities:
Two loops each supporting up to 30 iD biscuits
Module reports as either 4 or 8 zone expanders (8XP)
Fused 12V output for powering detectors
Local diagnostics using an engineer’s keypad
Biscuits are mapped to a fixed expansion zone
N Although the 60IXD expander module can support 60 zones of
expansion, you can only utilise the expandable zones available on the control
panel, e.g., If the Premier Elite control panel only supports two zone expanders,
you can only use a maximum of 16 iD biscuits (2 x 8).