8
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
In case of unexpected steam flow, connect piping from the exhaust
outlet to a safe area. Unexpectedly high steam volumes may cause
high-temperature condensate to be discharged through he exhaust
outlet, which may in turn cause burns or other injury.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Do not use excessive force when connecting threaded pipes to the
product. Over-tightening may cause breakage leading to fluid
discharge, which may cause burns or other injury.
CAUTION
Precautions before Installation
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
For the specific installation location of the SR, carefully consult the user.
Confirm the following items for the installation.
1. Before installing the SR, carefully discuss and ensure the installation and piping
method.
2. Do not install the SR near a stairway or emergency exit.
3. The surface for installation of the SR should be sturdy and horizontal.
As the SR is heavy equipment, anchor the legs securely on a strong and
horizontal foundation using the anchor bolts. (Dimension of anchor bolts: M16)
(Refer to the illustration on the next page regarding the position for anchor bolts
and number of anchor bolts required.)
4. For cases where people or products may come in contact with the SR unit, any
safety measures, such as insulation or isolation, should be implemented to
prevent injury.
Even if such contact is unlikely, it is recommended that the SR unit be as well
insulted as possible to increase heat efficiency.
5. Maintenance space should be secured.
Although the SR cannot be disassembled, maintenance space should be secured
for valves, etc.
(Refer to the illustration on the next page regarding maintenance space.)
6. If the SR is installed at height, make sure to install the SR such that there is
enough space to carry out maintenance work etc. with anti-drop measures such
as handrails having been implemented. We may not be able to perform technical
support service in a location where work cannot be safely carried out.