6ASSESSMENT AND EVALUATION
Inspection of the test surface can be performed using several methods.
Please note the used standard and check available methods.
Below given methods are often used for assessment:
10x Magnifying loupe: A magnifying loupe is the basic method for evaluation.
Visual checking for elongation, peeling and cracking of the coating.
Please note that visual assessment produces different results between different operators.
Chemical testing: Several test standards allow the use of chemically testing for cracking. These tests use chemicals
that react with the ferrous substrate of the test panel. These tests are less prawn to be influenced by
differences between different operators.
Voltage testing: Voltage testing is only possible on a fully closed coating surface. To ensure accurate interpretation a
reference panel has to be tested prior to performing the impact test. Check if this method is allowed
according to the standard.
7SAFETY AND MAINTENANCE
The TQC Impact tester has been designed to be as safe as possible. However as with all equipment the user needs to follow the
required safety instructions. Always ensure yourself that local health and safety regulations do not include any extra specifications.
7.1 Safety
To ensure safe operation please follow the following guidelines:
•Never put your hands under the tube when the weight is raised.
•Always have a stamp in place when testing.
•Make sure the TQC impact tester is positioned fully level.
7.2 Maintenance
The TQC impact tester does not require maintenance like calibration. However periodic review of wear and tear should be done. In
case of doubt of the state of your impact tester please contact your supplier.
8DISCLAIMER
The information given in this manual is not intended to be exhaustive and any person using the product for any purpose other than
that specifically recommended in this manual without first obtaining written confirmation from us as to the suitability of the product
for the intended purpose does so at his own risk. Whilst we endeavour to ensure that all advice we give about the product
(whether in this manual or otherwise) is correct we have no control over either the quality or condition of the product or the many
factors affecting the use and application of the product. Therefore, unless we specifically agree in writing to do so, we do not
accept any liability whatsoever or howsoever arising for the performance of the product or for any loss or damage (other than death
or personal injury resulting from our negligence) arising out of the use of the product. The information contained in this manual is
liable to modification from time to time in the light of experience and our policy of continuous product development.