Tribe FLATPAR3H Manuale utente

USER MANUAL
MANUALE UTENTE
FLATPAR3H
EN - IT
SUPERSLIM LEDPAR

All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals’section on site www.musiclights.it
REV.006-10/17

1
FLATPAR3H
Packing content • FLATPAR3H
• Power cord
• Mount bracket (2 pc.)
• User manual
TABLE OF CONTENTS Safety
General instructions
Warnings and installation precautions
1 Introduction
1. 1 Description
1. 2 Technical specications
1. 3 Operating elements and connections
2 Installation
2. 1 Mounting
3 Functions and settings
3. 1 Operation
3. 2 Basic
3. 3 Menu structure
3. 4 Auto Show
3. 5 Static color
3. 6 Sound mode
3. 7 Manual color
3. 8 Master/Slave mode
3. 9 Linking
3. 10 DMX mode
3. 11 DMX addressing
3. 12 Connection of the DMX line
3. 13 Construction of the DMX termination
3. 14 DMX control
3. 15 Dimmer
3. 16 Operation through the IRC Controller
4 Maintenance
4. 1 Maintenance and cleaning the unit
4. 2 Fuse replacement
4. 3 Trouble shooting
2
2
3
3
4
6
7
7
8
9
9
9
9
9
10
10
10
11
11
12
13
13
15
15
15

FLATPAR3H
2
SAFETY
General instruction
• The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
• The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
• Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
• The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
• This unit is not for home use, only professional applications.
• Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 45 °C.
• Make certain that no inammable liquids, water or metal objects enter the xture.
• Do not dismantle or modify the xture.
• All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
• If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
• If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
• Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
• Always additionally secure the projector with the safety rope.When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
• Install the xture in a well ventilated place.
• Keep any inammable material at a safe distance from the xture.
• Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
• The lamp (LED) shall be changed if it has become damaged or thermally deformed.
• Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
• Do not touch the product’s housing when operating because it may be very hot.
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.

3
FLATPAR3H
- 1 - INTRODUCTION
1.1 DESCRIPTION
FLATPAR3H is a super-slim LED PAR conceived to break ground with a new generation in its’range thanks
to the innovative light-source based on 6 colours, RGBWAP/full colour.
FLATPAR3H has been designed with signal and power connections on the sides and a at bottom, makng
it very useful for oor applications and as compact and powerful wall-washer. Its round shape and die-cast
aluminium housing with tempered glass panel makes FLATAR3H a nice design tool which can also be used
for in-sight applications at every kind of event such as as conferences, wedding parties, fashion events and
exhibitions.
1.2 TECHNICAL SPECIFICATIONS
LIGHT SOURCE
• Source: 3x8W RGBWAP LEDs
• CT: W: 6200K
• CRI: 70
• Luminous ux: 651.27lm
• Lux: 337lux @3m full
• Source life expectancy: >50.000 h
OPTICS
• Beam angle: 25°
• Field angle: 44°
• Lens diameter: 38mm
• Additional optics: 45° (optional)
COLOUR SYSTEM
• Colour mixing: RGBWAP/FC
• Colour wheel: virtual colour wheel with presets
DYNAMIC EFFECTS
• Static colour mode: selection of static colour
• Manual colour mode: manual adjustment of colour
• Auto mode: built-in programs with execution speed adjustment
• Sound mode: music activation through internal microphone and sensitivity control
BODY
• Body: sturdy die-cast aluminium body conceived for long-time durability
• Body colour: black
CONTROL
• Protocols: DMX512
• DMX channels: 6/8/10 channel
• Display: LED display user interface
• Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
• IR: infrared sensor controlled by remote
• Master/Slave: for synchronized operation of more units linked in a chain
ELECTRONICS
• Dimmer: linear 0~100% electronic dimmer
• Dimmer curves: 4 dierent dimming curves available
• Strobe / shutter: 1~28 Hz, electronic
• Operating temperature: -10° ~ +45°

FLATPAR3H
4
Fig.1
• Flicker: icker free operation
ELECTRICAL
• Power supply: 100-240V – 50/60Hz
• Power consumption (at 230V): 25.5W
• Power consumption (at 120V): 25.5W
• Output (at 230V): 47 units on a single power line
• Output (at 120V): 25 units on a single power line
PHYSICAL
• Cooling: natural cooling of the peculiar chassis and to absence of fans
• Sospension and xing: double hanging bracket suitable for safe hanging and for oor positioning
• Signal connection: XLR 3p IN/OUT connectors
• Power connection: IEC IN/OUT connectors
• IP rating: 30
• Dimensions (WxHxD): 187x152x187mm
• Weight: 1.68kg
152
187187

5
FLATPAR3H
1.3 OPERATING ELEMENTS AND CONNECTIONS
Fig.2
1. MOUNTING BRACKET
2. LOCKING KNOB for the mounting bracket.
3. MICROPHONE to control the show by the ex-
ternal audio signal.
4. CONTROL PANEL with display and 4 button
used to access the control panel functions and
manage them.
5. DMX IN (3-pole XLR): 1 = ground, 2 = DMX -, 3
= DMX +
6. DMX OUT (3-pole XLR): 1= ground, 2 = DMX -,
3 = DMX +
7. POWER IN mains plug for connection to a sock-
et (100-240V 50/60Hz) via the supplied mains
cable.The support for the mains fuse is located
near the mains plug. Only replace a blown fuse
by one of the same type (T1A 250V).
8. POWER OUT: connect to supply power to the
next unit.
9. SAFETY EYE to attach safety cable
10.GND POINT grounding the xture to the earth
Rear panel
5 7
1
2
3
4
6 8
9
10

FLATPAR3H
6
- 2 - INSTALLATION
2.1 MOUNTING
FLATPAR3H may be set up on a solid and even surface. The unit can also be mounted upside down to a
cross arm. For xing, stable mounting clips are required. The mounting place must be of sucient stability
and be able to support a weight of 10 times of the unit’s weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xture’s being used.
• Install the projector at a suitable location by means of the mounting bracket (1).
• Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
• Adjust the projector and use the knob (2) to slightly release or tighten the locking mechanism of the
bracket if is necessary.
Fig.3
1
2

7
FLATPAR3H
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
Connect the supplied main cable to a socket (100-240V~/50-60Hz). Then the unit is ready for operation
and can be operated via a DMX controller or it independently performs its show program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the LED Display
(g.4).
Fig.4 - Functions of the buttons
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
MENU UP
DOWNENTER

FLATPAR3H
8
3.3 MENU STRUCTURE
MENU (LEVEL 1) (LEVEL 2) REMARK
1 6 CH d (1-512)
2 8 CH d (1-512)
3 12 CH d (1-512)
4 C-- C 1 C1:R, C2:G, C3:B, C4:A, C5:W,
C 2 C6:P, C7:RG, C8:RB, C9:RA, C10:RW,
C 3 C11:RP, C12:GB, C13:GA, C14:GW, C15:GP,
C 4 C16:BA, C17:BW, C18:BP, C19:AW, C20:AP,
C 5 C21:WP, C22:RGB, C23:RGA, C24:RGW, C25:RGP,
C 6 C26:RBA, C27:RBW, C28:RBP, C29:RAW, C30:RAP,
C 7 C31:RWP, C32:GBA, C33:GBW, C34:GBP, C35:BAW,
C 8 C36:BAP, C37:AWP, C38:BWP, C39:GAW, C40:GAP,
C 9 C41:GWP, C42:RGBA, C43:RGBW, C44:RGBP, C45:RGAW,
C 10 C46:RGAP, C47:RGWP, C48:RBAW, C49:RBAP, C50:RBWP,
C 11 C51:RAWP, C52:GBAW, C53:GBAP, C54:GBWP, C55:GAWP,
... C56:BAWP, C57:RGBAW, C58:RGBAP, C59:RGBWP, C60:RGAWP,
C 63 C61:RBAWP, C62:GBAWP, C63:RGBAWP,
5P-- P 1 P 1: 6 Colors snap
P 2 P 2: 6 Colors fade
P 3 P 3: 63 Colors snap
P 4 P 4: 63 Colors fade
6 S-- S (1-100) Speed: 1-100 (slow-fast)
7 Snd Snd (1-2) Sound1: 6 colors
Sound2: 63 colors
8 Sens u (0-100)
9 U-- r(0-255)
g(0-255)
b(0-255)
A(0-255)
W(0-255)
P(0-255)
10 dIM OFF OFF: Dimmer speed o
dIM1 DIM1: Dimmer speed fast
dIM2 DIM2: Dimmer speed middle
dIM3 DIM3: Dimmer speed slow
11 SET On
OFF
Indice
Lingue:
Altri manuali Tribe Attrezzatura per DJ

Tribe
Tribe LUMIPAR12UAW Manuale utente

Tribe
Tribe FLATPAR3Q Manuale utente

Tribe
Tribe JETSPOT1 Manuale utente

Tribe
Tribe MINIVERSAPAR Manuale utente

Tribe
Tribe BATGOBOIR Manuale utente

Tribe
Tribe JETSPOT4Z Manuale utente

Tribe
Tribe Crystal Manuale utente

Tribe
Tribe FLATPAR6H Manuale utente

Tribe
Tribe SUNRISE2 Manuale utente

Tribe
Tribe LUMIPAR 12UQ PRO Manuale utente























