TrojanUV Trojanuvmax pro series Manuale utente

Congratulations. By purchasing this
COMM
center
, you have taken a significant
step in ensuring safe drinking water. Your
COMM
center
is designed to provide
you all the information you need, where you need it.
Date of installation: ______________________
Installed by: ______________________
Installer phone#: ______________________
Trojan Technologies
3020 Gore Road, London, Ontario, Canada N5V 4T7
www.trojanuv.com residential@trojanuv.com 1-800-265-5774
COMM
center
Owner’s Manual
Interested in a permanent,
unlimited record of system
performance, and a great
real-time interface? Try our
MAX
track
software - it's
completely free!
To learn more, visit:
http://protour.trojanuv.com


TABLE OF CONTENTS
Components 4
Installation 5
Operation 6
Navigation 6
Standard and Advanced Menu Settings 6
Welcome Page and Home Page 6
Menu Structure 7
What dose is being delivered? 8
How long has my lamp been running? 8
How long has my system been running? 8
What alarms are currently present?
9
What alarms have occurred? 9
How many more days should my lamp last? 10
How can I reset the lamp run hours after installing a new lamp? 10
Who do I contact for help? 10
What firmware revision do I have? 10
How do I set the time? 11
How do I set the date? 11
How do I change the menu mode? 12
How do adjust the screen contrast? 12
How do I adjust the volume of the audible alarm? 13
How do I permanently remove a unit? 14
How do I reset all addresses? 14
How do I remove a unit? 15
How do I re-install a unit? 15
How do I turn off a unit for servicing? 16
How do I turn a unit on after servicing? 16
Data-logging 17
Using a mini-SD card 17
Using MAXtrack software 18
Warranty 19
INSTALLATION
COMPONENTS
WARRANTYDATA-LOGGINGOPERATION

INSTALLATIONWARRANTY DATA-LOGGING OPERATION COMPONENTS
4
COMPONENTS
Purchased separately:
To connect multiple units:
RJ45 cable(s). Available from Trojan and retailers. One is provided with each COMMcenter.
To connect to a computer:
Telephone cable. Available from various retailers.
To data-log with a mini-SD card:
Mini-SD card and mini-SD card reader. Available from various retailers.
•
•
•
Example of a
card reader
Example of a
mini-SD card
RJ45 (Ethernet) cable
Part #602942
(not exactly as shown)
COMMcenter
Part #650623-001
(includes parts #602942 and 602982)
RJ11 to RS232 adapter
Part #602982

INSTALLATION
COMPONENTS WARRANTYDATA-LOGGINGOPERATION
5
INSTALLATION
Install TrojanUVMax water treatment unit(s) if required. A "unit" is a complete system.
Make sure the unit(s) are powered.
Install COMMcenter on wall if so desired (it may also rest on a flat surface). Mounting holes are 2.5" (6.8 cm)
apart. If using RJ45 (Ethernet) cable, COMMcenter may be installed at any distance from unit(s). If using a
wireless connection, please refer to wireless instructions provided with your system to determine maximum
distance.
If connecting to a single unit, connect the unit's power supply (pictured below) to the COMMcenter using the
cable provided with the COMMcenter. To connect to multiple units, see box below then return to step 5.
Please read pages 6 and 7 to familiarize yourself with the basic operations of the COMMcenter.
Set the time and date on the COMMcenter (refer to page 11).
If data-logging is desired, insert mini-SD card or connect to computer using MAXtrack software (free; to learn
more, visit http://protour.trojanuv.com). For details, refer to "Data-logging" section.
1.
2.
3.
4.
5.
6.
7.
Connect cable here
(port for line out)
COMMcenter Unit 3Unit 1 Unit 2
Installations involving multiple units
Up to 9 units may be linked to the COMMcenter. Make the required connections in the sequence
illustrated below. The port closest to the front of each power supply is for the line out; the port closest
to the back is for the line in. Only one Ethernet connection cable is provided with the COMMcenter -
additional cables may be purchased (part # 602942).
The units are identified by an "address". Until they have been connected, all units are addressed
('numbered') "zero". The COMMcenter assigns each unit an address when first connected. Each unit then
retains the address it is assigned, even when unplugged or connected to another COMMcenter.
Step 1Step 2Step 3
Out
In
Out
Out
In
In

INSTALLATIONWARRANTY DATA-LOGGING OPERATION COMPONENTS
6
OPERATION
Navigation
There are four buttons on the COMMcenter. Their function corresponds to what is displayed on the screen next to
each button, as illustrated below.
Standard And Advanced Menu Settings
There are two menu settings, Standard and Advanced. For the features of each, refer to the Menu Structure on
the next page. When the COMMcenter is connected to more than one unit, it defaults to Advanced Menus mode.
Otherwise, this mode may be selected - see "How do I change the menu mode?".
Welcome Page and Home Page
The Welcome page appears during start-up. Left unattended, the COMMcenter will alternate between the
Welcome page and the Home page. The latter displays the most critical information about the performance of the
unit(s). To view the menu options from the Welcome page or the Home page, press any button.
Legend:
a Dose 45, nearing alarm set point.
b Dose 40, alarm set point. Unit will shut solenoid valve (if so equipped) below this level.
Home page
Advanced menus mode
(2 units)
Home page
Standard menus mode
Welcome page
a b
a
b
Use this button to move up
through options.
Use this button to move down
through options.
This button does not have an
assigned function on this screen.
Use this button to select
"Settings"

INSTALLATIONCOMPONENTS WARRANTYDATA-LOGGING
OPERATION
7
Menu Structure
Screens with a double outline are only visible when in Advanced Menus mode.
Tip:
Most screens are
numbered.
Tip:
Use the buttons on the
right to navigate up and
down the selections.

INSTALLATIONWARRANTY DATA-LOGGING OPERATION COMPONENTS
8
What dose is being delivered?
How long has my lamp been running?
How long has my system been running?
One screen for each unit, up to a maximum
of 9. Navigate between units using buttons
on the right. If only one unit is present, this
is the Home page.
Note: The Home page for multiple
systems is also useful as it displays the
dose being delivered by each unit. It may
be viewed by selecting the following:

INSTALLATIONCOMPONENTS WARRANTYDATA-LOGGING
OPERATION
9
What alarms are currently present?
Alarms must first be acknowledged by pressing
any button on the COMMcenter or by pressing
the Mute button on the power supply. This does
not remove the alarm condition. Note: the "Alarms"
screens may only be viewed when in Advanced
Menus mode.
Use buttons on right
to select alarm
What alarms have occurred?
The COMMcenter stores the last 40 alarms that
have occurred in memory. For greater data-logging
capability, including the ability to data-log dose,
use our free MAXtrack software or insert a mini-
SD card. Note: the "Alarms" screens may only be
viewed when in Advanced Menus mode.
Use buttons on right
to select alarm
You can review
helpful advice by
simply pressing the
bottom left button.

INSTALLATIONWARRANTY DATA-LOGGING OPERATION COMPONENTS
10
How can I reset the lamp run hours
after installing a new lamp?
The lamp run hours can also be reset at the power
supply. See system Owner's Manual for details.
Note: the "Lamp Hours" screens may only be
viewed when in Advanced Menus mode.
What firmware revision do I have?
How many more days should
my lamp last?
Note: the "Lamp Hours" screens may only be
viewed when in Advanced Menus mode.
Who do I contact for help?
Use buttons on right
to choose unit.
Use buttons on right to
choose COMMcenter or
ballast interface (power
supply).
Indice
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente