TYROLIT Hydrostress WSE1217P Manuale utente

Operating Instructions
Control unit WSE1217
Index 000
Original operating instructions
10991497en / 15.11.2016

Page 2
TYROLIT Hydrostress AG
Witzbergstrasse 18
CH-8330 Pfäkon
Switzerland
Tel. 0041 (1) 952 18 18
Fax 0041 (1) 952 18 00
Congratulations!
With a Hydrostress unit from TYROLIT, you have chosen a tried and tested piece of equipment
which has been designed and built to leading technical standards. Only genuine TYROLIT Hy-
drostress replacement parts can guarantee quality and interchangeability. If maintenance work
is neglected or carried out inexpertly we will be unable to honour our warranty obligations. Any
repair work must be carried out by trained personnel only.
Our after sales service is available to help ensure that your TYROLIT Hydrostress units remain in
perfect working order.
We hope that working with your TYROLIT unit will be a satisfying and fault-free experience.
TYROLIT Hydrostress
Copyright © TYROLIT Hydrostress

TYROLIT Hydrostress AG
Page 3
Safety
DANGER
Failure to comply with the safety instructions in the «Safety Manuals / System Handbooks» may
result in serious injuries or even death.
XMake sure that the «Safety Manuals / System Descriptions» for the relevant type of saw have
been fully read and understood.
DANGER
Death or serious injury can be caused by sudden start-up of the machine.
XBefore switching on the system, ensure that no other persons are present in the danger areas.
XSwitch the system o before connecting or disconnecting cables.
XSwitch the system o when you leave and secure it so that it cannot be switched back on
again.
Death or serious injury as a result of the sawing machine continuing to run after an acci-
dent.
XEnsure that the EMERGENCY STOP button can be reached quickly.
Electric shock from live cables and connectors.
XSwitch o the control unit WSE1217 before connecting or disconnecting cables.
XEnsure that the power supply is earthed and tted with a residual current operated protec-
tive device (FI Typ B) with a maximum residual current of 30mA.
Risk of re due to incorrect mains voltage.
XMake sure that the mains voltage and mains frequency match control unit mains settings
WSE1217.
In case of emergency
XPress the EMERGENCY STOP button on the remote controller.
If the EMERGENCY STOP is activated on the radio remote controller, the LED warning light ash-
es rapidly.
In an emergency the sawing machine can be also switched o using the main switch on the
control unit WSE1217.
EMERGENCY STOP
1
1.1

TYROLIT Hydrostress AG
Page 4
Description
Main components control unit
Main components control unit
1 Operating hours counter 7 Water connection / water outlet
2 Main switch 8 Main motor connection
3 Feed motor connection 9 Name plate
4 Remote controller connection 10 Indicator lights
5 Mains connector 11 Mains system selection button
6 Water nipple / water inlet 12 Reset button
Main components remote controller
Main components remote controller
1 Feed potentiometer 8 Pulse switch Control unit
2 On / O main motor 9 EMERGENCY STOP
3 Main motor potentiometer 10 Indicator lights
4 Water On / O 11 Warning light (radio & battery)
5 Diameter selector switch 12 Position lock switch (Traverse feed)
6 Traverse feed joystick 13 Casing
7 Starter switch
2
2.1
2.2

TYROLIT Hydrostress AG
Page 5
Remote controller
The remote controller can be replaced by an accumulator or a battery operated radio remote
controller. Additionally the remote controller can be operated using a cable.
Radio remote control
The transmitter and receiver are a pair of matched units. They cannot be used with other devices.
Operating modes
Rechargeable battery operation:
The interchangeable rechargeable battery is inserted in the base of the casing. The operating
period with a fully charged battery is approximately 12 hours. The reception distance is 25 m.
Battery operation:
The battery holder included in the scope of supply allows operation with three 1.5 V AA batter-
ies. The reception distance is 25 m.
Cable operation:
The cable insert included in the scope of supply allows connection of the remote controller to
the control unit WSE1217. The cable length is 10 m. Cable operation makes it possible to
work in areas where radio operation is not allowed (e.g. hospitals)..
With cable operation all control signals are transmitted via the power cable.
The rechargeable/ordinary battery holders may not be inserted in the base of the casing during
cable operation.
2.3
2.4

TYROLIT Hydrostress AG
Page 6
Accessories Remote control
The battery charger is exclusively for recharging the interchangeable rechargeable battery. The
battery holder and the cable insert must not be inserted.
Accessories
1 2x Interchangeable rechargeable batteries No. 10984306
2 Rechargeable battery charger No. 10984305
Rechargeable battery charger with
10-30 VDC connection
No.10984840
3 Remote control cable No. 10991362
4 Battery holder No. 10984307
5 Key No. 10984309
2.5

TYROLIT Hydrostress AG
Page 7
Connections
Making remote control and motor connections
9The control unit is isolated from the power supply
9Connectors/plugs are clean
9Cables are undamaged
X
Making the mains connection and water supply
9The power supply is earthed and tted with a residual current operated protective device
(FI Typ B; max. residual current 30mA)
9Cable cross-section is sucient: for up to 25 m long 5 x 4 mm2, more than 25 m long 5 x 6 mm2
3
3.1
3.2

TYROLIT Hydrostress AG
Page 8
Operation
Overview of operating elements
Operating elements
1 Position lock switch (Traverse feed) 8 Main motor potentiometer
2 Water On / O 9 Diameter selector switch
3 EMERGENCY STOP 10 Traverse feed joystick
4 Pulse switch Control unit 11 Main switch Control unit
5 Starter switch 12 Reset button
6 Feed potentiometer 13 Mains system selection button
7 On / O Main motor
The control unit WSE1217 can also be used for wire sawing and core drilling with suitable
TYROLIT Hydrostress system components.
Wire sawing:
To change to the control unit WSE1217 wire sawing mode the rotary switch (9) (diameter
selector switch) is turned to the symbol wire sawing.
4
4.1

TYROLIT Hydrostress AG
Page 9
Starting the control unit WSE1217
CAUTION
The control unit WSE1217 can be damaged if it slips or overturns!
XMake sure that the control unit WSE1217 stands horizontally (handle at top).
9Control unit WSE1217 is connected to the mains and the water supply.
9The sawing machine is connected to the control unit WSE1217.
(see «Operating instructions - Sawing machine )
9The remote control EMERGENCY STOP has been deactivated.
Starting the control unit WSE1217
XMove the controls shown below on the remote controller to the 0 position.
Feed potentiometer (6)
Starter switch (5)
Feed joy stick (10)
Main motor On/O (7)
XSwitch on the control unit WSE1217 using the main switch (11).
XSwitch on the radio remote controller using the starter switch (5).
–Warning lights (radio and battery) at rst show red
–An audible signal sounds simultaneously
–Indicators ash coloured
–Second audible signal sounds
–Indicators show coloured
–Warning light ashes green
XPress the remote control pulse switch (4) briey in the ON-position.
All indicator lights except the warning lights and the group alarm on the remote controller
go o.
XPress the reset button (12) on the control unit.
XPress the remote control pulse switch (4) briey in the ON-position.
The the control unit 'ready' lights show green.
XOpen the water valve on the system supply line.
XPress the Water On/O switch (2) on the remote control unit to I.
–Water ows from the cutting tool
XPress the main motor On/O switch (7) on the remote controller to position I.
–The electric motor starts if the main motor potentiometer is at the max. position.
XThe control unit WSE1217 has started and ready for operation.
4.2

TYROLIT Hydrostress AG
Page 10
Remote control frequency change
Remote control frequency change
The remote control systems are equipped with a frequency generator for frequency selection.
If the systems malfunction or the radio link is interrupted (another transmitter, range, empty
battery), the systems immediately go into EMERGENCY OFF mode.
New frequency search:
You can select the next frequency by switching the start switch on the remote control o and
back on.
The o/on switching procedure is limited to four attempts (channels). If the system has not
found a suitable frequency after four attempts, you must change to cable operation.
4.2.1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali TYROLIT Hydrostress Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente