Viavi FVAi-2030 Manuale utente

Multiple Application Platform
FVAi-2030 Benchtop Microscope
User Guide
22112369-339 R000, Standard
December 2021

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard ii
Copyright
Copyright © 2021 VIAVI Solutions Inc. All rights reserved. VIAVI and FiberChekPRO™ are trademarks or registered
trademarks of VIAVI in the United States and/or other countries. All other trademarks and registered trademarks
are the property of their respective owners. No part of this guide may be reproduced or transmitted,
electronically or otherwise, without written permission of the publisher.
Every effort was made to ensure that the information in this manual was accurate at the time of printing.
However, information is subject to change without notice, and VIAVI reserves the right to provide an addendum
to this manual with information not available at the time that this manual was created.
Patents
Patented as described at www.viavisolutions.com/patents.
Terms and Conditions
Specifications, terms, and conditions are subject to change without notice. The provision of hardware, services,
and/or software are subject to VIAVI standard terms and conditions, available at www.viavisolutions.com/terms.
Warranty
VIAVI warrants this equipment to be free of defects in material and workmanship for one (1) calendar year from
the date of purchase. Any mishandling or unauthorized repairs will void this warranty. For additional warranty
terms and conditions, see www.viavisolutions.com/terms.
Disclaimer
The foregoing warranties are in lieu of all other warranties and conditions, expressed or implied. VIAVI specifically
disclaims all other warranties, either expressed or implied, on any hardware, documentation or services including
but not limited to warranties relating to quality, performance, non-infringement, merchantability or fitness for a
purpose, as well as those arising from any course of dealing, usage or trade practice. Under no circumstances will
VIAVI be liable for any indirect or consequential damages related to breach of this warranty.
California Proposition 65
California Proposition 65, officially known as the Safe Drinking Water and Toxic Enforcement Act of 1986, was
enacted in November 1986 with the aim of protecting individuals in the state of California and the state's drinking
water and environment from excessive exposure to chemicals known to the state to cause cancer, birth defects or
other reproductive harm. For the VIAVI position statement on the use of Proposition 65 chemicals in VIAVI
products, see the Hazardous Substance Control section of the VIAVI Policies & Standards web page.
Federal Communications Commission (FCC) Notice
Electronic test equipment is exempt from Part 15 compliance (FCC) in the United States.
EU WEEE and Battery Directives
This product, and the batteries used to power the product, should not be disposed of as unsorted municipal waste
and should be collected separately and disposed of according to your national regulations.
VIAVI has established a take-back processes in compliance with the EU Waste Electrical and Electronic Equipment
(WEEE) Directive, 2012/19/EU, and the EU Battery Directive, 2006/66/EC. Instructions for returning waste
equipment and batteries to VIAVI can be found in the WEEE section of the VIAVI Policies & Standards web page.
If you have questions concerning disposal of your equipment or batteries, contact the VIAVI WEEE Program
Management team at WEEE.EMEA@ViaviSolutions.com.
EU REACH
Article 33 of EU REACH regulation (EC) No 1907/2006 requires article suppliers to provide information if a listed
Substances of Very High Concern (SVHC) is present in an article above a certain threshold. For information on the
presence of REACH SVHCs in VIAVI products, see the Hazardous Substance Control section of the VIAVI Policies &
Standards web page.

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard iii
EU CE Marking Directives (LV, EMC, RoHS, RE)
This product conforms with all applicable CE marking directives. Please request the EU Declaration of Conformity
for details.
China RoHS materials declaration
7047 E. Greenway Parkway, Suite 250
Scottsdale, AZ 85254, USA
22157638, Rev
000
“ѝѝഭRoHS”
lj⭥ᆀؑӗ૱⊑ḃ᧗ࡦ㇑⨶࣎⌅NJ˄ؑӗъ䜘ˈㅜ 39 ˅
䱴ᖅ (Additional Information required for the Chinese Market only)
ᵜ䱴ᖅ᤹➗Āѝഭ RoHSāⲴ㾱≲䈤᰾Ҷᴹޣ⭥ᆀؑӗ૱⧟؍֯⭘ᵏ䲀ⲴᛵߥˈᒦࡇࠪҶӗ૱ѝᴹ
Ⲵᴹ∂ǃᴹᇣ⢙䍘Ⲵ㊫઼ᡰ൘䜘ԦDŽᵜ䱴ᖅ䘲⭘Ҿӗ૱ѫփ઼ᡰᴹ䝽ԦDŽ
ӗ૱㌫ࡇ: FVAi Series Bench-Top Microscope with Integrated LCD Autofocus 30x
(Product Family)
⧟؍֯⭘ᵏ䲀˖
ᵜḷ䇶ḷ⌘Ҿӗ૱ѫփѻкˈ㺘᰾䈕ӗ૱ᡆަ䝽Ԧᴹᴹ∂ǃᴹᇣ⢙䍘˄䈖ᛵ㿱л
㺘˅DŽ
ަѝⲴᮠᆇԓ㺘൘↓ᑨᶑԦл㠣ቁ൘ӗ૱⭏ӗᰕᵏѻᮠᒤ䈕ӗ૱ᡆަ䝽Ԧ
ᴹⲴᴹ∂ǃᴹᇣ⢙䍘нՊᔲᡆ⋴┿DŽ䈕ᵏ䲀н䘲⭘Ҿ䈨ྲ⭥⊐ㅹ᱃㙇૱DŽ
ᴹޣ↓ᑨᶑԦˈ䈧৲㿱ӗ૱⭘ᡧDŽ
ӗ૱⭏ӗᰕᵏ䈧৲㿱ӗ૱Ⲵṑ߶䇱ҖDŽ
ᴹ∂ǃᴹᇣ⢙䍘Ⲵ㊫ර઼ᡰ൘䜘Ԧ
ᴹ∂ǃᴹᇣ⢙䍘઼ݳ㍐
ݳಘԦ
(Component)
䫵(Pb)
⊎(Hg)
䭹(Cd)
ޝԧ䬜
(CR
6+
)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟䟊
(PBDE)
ӗ૱ѫփ
(Main Product)
ঠࡧ⭥䐟ᶯ㓴Ԧ
(PCB Assemblies)
X
O
O
O
O
O
䜘䝽㓯
(Internal wiring)
X
O
O
O
O
O
ᱮ⽪ಘ
(Display)
X
O
O
O
O
O
䭞ⴈ
(Keyboard)
O
O
O
O
O
O
⭥⊐
(Batteries)
O
O
O
O
O
O
⭥Ⓚ
(Power Supply)
X
O
O
O
O
O
c⭥ᐕ䴦Ԧ
(Electro-mechanical parts)
X
O
O
O
O
O
⺜ⴈ
(Hard Drive)
O
O
O
O
O
O
ݹ⁑ඇ / 䖵ࣙ⁑ඇ
(Optical modules) / (Auxiliary modules)
X
O
O
O
O
O
䠁ཆ༣䴦Ԧ઼㍗ᢓԦ
(Metal case parts and fixings)
X
O
O
O
O
O
ກᯉཆ༣䴦Ԧ
(Plastic case parts)
O
O
O
O
O
O
ḷㆮ઼㜦ᑖ
(Labels and tapes)
O
O
O
O
O
O
䝽Ԧ
(Accessories)
ཆ᧕⭥㔶઼䘲䝽ಘ
(External cables and adapters)
X
O
O
O
O
O
઼ަᆳঠࡧᶀᯉ
(Handbooks and other printed material)
O
O
O
O
O
O
㻵㇡઼㕊ᑖ
(Carrying case and strap)
O
O
O
O
O
O
ަᆳ䝽Ԧ
(Other accessories)
O
O
O
O
O
O
ᵜ㺘ᱟ᤹➗
S / T 11364
Ⲵ㿴ᇊ㕆ࡦⲴ
:
O
˖㺘⽪䈕ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴ䟿൷൘ GB/T 26572 㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
X
˖㺘⽪䈕ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴ䟿䎵ࠪ GB/T 26572 㿴ᇊⲴ䲀䟿㾱≲DŽ

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard iv
Contents
1 Overview.....................................................................................................................................1-1
Ordering information.......................................................................................................................... 1-2
Technical Assistance Center and Knowledge Base ............................................................................. 1-3
2 Getting started ............................................................................................................................2-1
Features .............................................................................................................................................. 2-2
Powering the FVAi-2030 microscope on or off................................................................................... 2-3
Mounting fiber adapters and connectors........................................................................................... 2-4
Navigating the Home screen .............................................................................................................. 2-6
Accessing Live view............................................................................................................................. 2-8
Applying a profile and an optical setting .......................................................................................... 2-10
Managing groups .............................................................................................................................. 2-12
Managing user information .............................................................................................................. 2-14
Managing microscope settings ......................................................................................................... 2-15
Managing the Fiber Centering Limit setting and marker ........................................................... 2-16
Managing image-save options.......................................................................................................... 2-18
Managing system settings ................................................................................................................ 2-19
Calibrating the touchscreen....................................................................................................... 2-20
Connecting and activating a supported USB device ......................................................................... 2-21
Activating a P5000i probe .......................................................................................................... 2-21
Activating an MP Series optical power meter............................................................................ 2-23
3 Fiber inspection during standalone operation..............................................................................3-1
Requirements for Pass/Fail tests ........................................................................................................ 3-2
Starting a Pass/Fail test from the FVAi-2030 ...................................................................................... 3-3
Viewing the fiber chamfer .................................................................................................................. 3-4
Capturing images................................................................................................................................ 3-5
Recalling test results and images........................................................................................................ 3-7
4 Using the FVAi-2030 microscope with FiberChekPRO...................................................................4-1
Connecting to FiberChekPRO.............................................................................................................. 4-2
Performing Pass/Fail tests and generating reports ............................................................................ 4-3
Viewing the fiber chamfer with FiberChekPRO .................................................................................. 4-5
Creating analysis profiles for the FVAi-2030 microscope ................................................................... 4-6
Appendix A Firmware update ........................................................................................................... A-1
Appendix B System reset .................................................................................................................. B-1
Appendix C Specifications ..................................................................................................................C-1
Appendix D Document revision history ............................................................................................ D-1

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard v
About this guide
This guide provides information about the FVAi-2030 Benchtop Microscope. This is the first release of this user
guide. For a detailed revision history, see “Document revision history” on page D-1.
To access the latest version of this user guide, go to:
FVAi-2030 Benchtop Microscope User Guide, 22112369-339

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard 1-1
1 Overview
The FVAi-2030 Benchtop Microscope is the ideal microscope to control contamination during optical connector
manufacturing. Equipped with 30x optics, ultra-wide field-of-view, dual magnification, automatic focus, and built-
in end face analysis, the FVAi-2030 gives operators fast and complete visibility of the entire ferrule end face so
that any contamination on or near the fiber end face can be quickly found.
Operators can use the FVAi-2030 as a standalone device or in conjunction with the FiberChekPRO™ inspection
and analysis software.
Figure 1-1: FVAi-2030 Benchtop Microscope
FiberChekPRO Fiber Inspection and Analysis software
Designed to operate on a PC/laptop, FiberChekPRO instantly captures, analyzes, and grades fiber end-face images
to determine acceptability of the end faces. It identifies and characterizes defects and contamination, and then
provides a pass or fail result according to preconfigured criteria. In addition, users can customize settings, as well
as archive data and generate reports.
This section covers the following information:
•“Ordering information” on page 1-2
•“Technical Assistance Center and Knowledge Base” on page 1-3

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard 1-2
Overview Ordering information
Ordering information
Table 1-1: FVAi-2030 Benchtop Microscope
Description Part Number
FVAi-2030 Large Field of View Benchtop Microscope1 with Integrated LCD, Autofocus 30x
1. Includes M5 hex screwdriver, power adapter, and USB cable.
FVAi-2030
Table 1-2: Supported fiber adapters
Description Part Number
LC/APC Duplex Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-LCA-DUX-SL35
LC/APC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-LCA-SL35
LC/PC Duplex Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-LC-DUX-SL35
LC/PC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-LC-SL35
SC/APC Fiber Microscope Adapter, 30-Degree Chamfer Angle FMAX-SCA-SL30
SC/APC Fiber Microscope Adapter, 41-Degree Chamfer Angle FMAX-SCA-SL41
SC/PC Duplex Fiber Microscope Adapter. 30-Degree Chamfer Angle FMAX-SC-DUX-SL30
SC/PC Fiber Microscope Adapter, 30-Degree Chamfer Angle FMAX-SC-SL30
Universal 1.25mm APC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-U12A-SL35
Universal 1.25mm PC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-U12-SL35
Universal 2.5mm APC Fiber Microscope Adapter, 30-Degree Chamfer Angle FMAX-U25A-SL30
Universal 2.5mm APC Fiber Microscope Adapter, 41-Degree Chamfer Angle FMAX-U25A-SL41
Universal 2.5mm PC Fiber Microscope Adapter, 30-Degree Chamfer Angle FMAX-U25-SL30
CS/APC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-CS-APC-SL35
CS/PC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-CS-SL35
MDC/APC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-MDC-APC-SL35
MDC/PC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-MDC-SL35
SN/APC Duplex Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-SN-APC-SL35
SN/PC Fiber Microscope Adapter, 35-Degree Chamfer Angle FMAX-SN-SL35

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard 1-3
Overview Technical Assistance Center and Knowledge Base
Technical Assistance Center and Knowledge Base
To find the Technical Assistance Center phone number and email in your region for the FVAi-2030 Benchtop
Microscope or to search the VIAVI Solutions Knowledge Base, visit the VIAVI Solutions Technical & Product
Support site at support.viavisolutions.com.

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard 2-1
2 Getting started
This section covers the following information:
•“Features” on page 2-2
•“Powering the FVAi-2030 microscope on or off” on page 2-3
•“Mounting fiber adapters and connectors” on page 2-4
•“Navigating the Home screen” on page 2-6
•“Accessing Live view” on page 2-8
•“Applying a profile and an optical setting” on page 2-10
•“Managing groups” on page 2-12
•“Managing user information” on page 2-14
•“Managing microscope settings” on page 2-15
•“Managing image-save options” on page 2-18
•“Managing system settings” on page 2-19
•“Connecting and activating a supported USB device” on page 2-21

FVAi-2030 Benchtop Microscope User Guide, 22112369-339 R000, Standard 2-2
Getting started Features
Features
Figure 2-1: FVAi-2030 microscope features (without adapter)
Table 2-1: FVAi-2030 microscope features - rear panel
Label Description
Power switch (ON/OFF). See “Powering the FVAi-2030 microscope on or off” on page 2-3).
Power adapter receptacle
USB-B Interface (1x) for connecting the FVAi-2030 microscope to a computer for use with FiberChekPRO
inspection software. See “Using the FVAi-2030 microscope with FiberChekPRO” on page 4-1.
USB Interfaces (2x) for connecting supported USB devices to FVAi-2030 microscope. See “Connecting and
activating a supported USB device” on page 2-21.
VGA Interface for connecting the FVAi-2030 microscope to an external monitor.
Indice
Altri manuali Viavi Microscopio

Viavi
Viavi INX 760 Manuale utente

Viavi
Viavi P5000i Manuale elenco delle parti

Viavi
Viavi FVAm Series Manuale utente

Viavi
Viavi FiberChek Manuale elenco delle parti

Viavi
Viavi FiberChek Manuale utente

Viavi
Viavi P5000i Manuale elenco delle parti

Viavi
Viavi FiberChek Manuale utente

Viavi
Viavi P5000i Manuale elenco delle parti

Viavi
Viavi OneAdvisor ONA-800 Manuale elenco delle parti

Viavi
Viavi P5000i Manuale utente

















