Vitek Transcendent 5 Series Manuale utente

VITEK
VITEK
VTC-TNB5TH
VT-BB501
Transcendent Series 5 MegaPixel
Bi-Spectrum Long-Range Thermal
WDR IP Motorized Bullet Camera
QUICK START GUIDE
FEATURES - VISIBLE LIGHT
• 1/2.7” 5.0 Megapixel CMOS Image Sensor
• 5MP (2592 × 1944) @30 fps
• 8mm @ F2.0 Fixed Iris Lens (1/30s ~ 1/100000s)
• Field of View - 38°×27.5°(H×V)
• Captures 30 Faces Simultaneously
• Built-In White Light and Loudspeaker
• 120Db True Wide Dynamic Range (WDR)
• XD-DNR (3D & 2D Digital Noise Reduction)
• BLC, HLC, De-Fog
FEATURES - THERMAL LIGHT
• 17um 384×288 Vanadium Oxide Uncooled Focal Plane Detector
• Noise Equivalen Temp. Difference (NETD): <35mK(@25°C, F#=1.0)
• S12.3mm@F1 Thermal Imaging Lens
• 29.7°×22.5°(H × V)
• Minimum Focus Distance: 4’5” (1.34m)
• Temperature Measuring Distance 6’6”~20’ (2~6m)
• Black, White, Pseudo-color
GENERAL FEATURES
• Fully Programmable Gen. III Advanced Analytics: Face Detection, Target Counting,
Intrusion, Region Entrance / Exit, Line Crossing, Scene Change, Video Blur
• H.265/H.264/MJPEG
• Remote Viewing via CMS, Internet Explorer, iOS & Android Apps
• MicroSD Card Slot for Local Recording (256GB)
• Sound and Light Warning
• 1 Ch. Audio In + 1 Ch. Audio Out
• 1 Ch. Alarm Input + 1 Ch. Alarm Output
• ONVIF Compliant
• IP66 Weather Resistance
• 12VDC & PoE (Power over Ethernet) Operation
• Ceiling or Wall Mounting Feasability with Included Mount (Other Accessories Sold
Separately - See Following Page)
• 2-Year Warranty
*Please research local, state and federal laws regarding the implementation of audio surveillance.
PLEASE NOTE:
Complete User Guide, Software, Tools, and Updates are
available online. Scan the QR Code or visit:
http://www.vitekcctv.com/Downloads
PLUS
+
VT-BB501 - Black Body Temperature
Calibration Device (sold separately)

2 3
Camera Components and Accessories
.98”/25mm
.20”/5mm
.20”/10mm
Camera Overview
Allen Key
Tripod
Adapter
Plate

3
Weather Resistant Network Coupler
1. Loosen the nut from the Weather Resistant Network Coupler,
2. Run ethernet cable through coupler, then attach a RJ-45 connector.
3. Tighten the nut and coupler for a weather resistant seal.
Connecting Alarm Input / Output
Camera Installation
Install SD Card
1. Remove the MicroSD card slot cover.
2. Insert a MicroSD card.
3. Check if the water-resistant ring is
installed properly before re-installing the slot
cover. Tighten screws firmly.
Wall or Ceiling Mounting: Make sure the wall or ceiling can support 3X the
device’s weight. Install in dry conditions, free of dust and debris.
2.54”
2.54” .2” / 5mm
1. Drill the screw holes and the
cable hole on the wall according to
the drill template.
2. Route the cables and connect the relevant cables.
3. Fasten the mounting base to the wall/ceiling with
the screws provided.

4 5
4. BRACKET ADJUSTMENT.
Before adjustment, preview the image
of the camera on a monitor and loosen
the fixed screws to adjust the view
angle of the camera. After that, tighten
the fixed screws.
VTC-TNB5TH Camera Installation with Tripod
1. Screw the adapter onto the tripod (sold separately from camera).
2. Route and connect cables. Align the holes of the mounting base with the holes (b) of the
adapter. Attach the camera to the adapter with the screws provided.

5
VT-BB501 Blackbody Installation with Tripod
1. Align the holes of the blackbody with the holes of the adapter as shown below. Then fasten
the blackbody to the adapter with screws.
2. Screw the adapter with the black body onto the tripod (sold separately from blackbody).
Installation and Use Requirements (See Diagram on Next Page)
- In order to ensure accuracy in temp. measurement, the recomended ambient temp. is
50~95°F (10~35°C), and the infrared light should be turned off during temp. measurement.
- The VTC-TNB5TH can be used independently, but will provide greater accuracy when used
with the blackbody callibration device, VT-BB501 (sold separately).
- The VTC-TNB5TH should be used in a stable, wind-free indoor environment. Make sure the
monitoring field is far away from any objects that could produce airflow, high temp. or reflection.
- Avoid installation near a door or an air conditioner, or any place in direct sunshine.
- The recommended monitoring distance is 2~6m 6’7”~19’8”. To monitor an aisle, the best
temperature measurement distance is 6’7”~13’9” (2~4M).
- Set up a 1-way temp. measuring zone and make sure the camera can clearly see subjects’
faces.
- The VTC-TNB5TH requires 20-30 minutes after powering up to give steady readings.
- It is recommended to use DC 12V power supply to reduce power consumption.
- If the VT-BB501 is used with the camera, it should be installed 6’7”~9’9” (2-3M) away from
the camera. It cannot be blocked. During operation, do not move the camera or black body
callibration device, and make sure the VT-BB501 is positioned in a proper place within
the camera image.

6 7
Ideal Temperature Measurement Range
0-6’7” 6’7”-13’4” 13’4”-19’8”
6’7”-9’9”
6’7”-9’9”
*Always keep VT-BB501 within view
of VTC-TNB5TH
50~95°F
(10~35°C)
Steps for Setting Temp. Measurement Are as Follows:
Log In Web Client > Enable Face Detection > Temperature Meausre > Temperature Calibration Settings
LAN Configuration
The camera can be accessed on the local network either using the
IP-Tool or directly in a web browser.
Accessing the Camera Using the IP-Tool
1. Make sure the camera and PC are connected to the LAN.
2. Locate the IP-Tool installer at www.
vitekcctv.com/Downloads/Soft-
ware/Transcendent-IPTool_v2.0.2.zip
, then install on the PC. Open
the installed application.
3. Modify the IP address. The default IP address is 192.168.226.201.
Click the information of the camera listed in the above table to show
the network information on the right side. Modify the IP address and
gateway of the camera and make sure its network address is in the
same local network segment as the computer’s. Please modify the
IP address of your device according to the practical situation.
For example, the IP address of your computer
is 192.168.13.4. So the IP address of the
camera shall be changed to 192.168.13.X.
After modification, please input the password
of the administrator and click “Modify” button
to modify the setting.
** Default admin password: “123456".

7
LAN Configuration
The camera can be accessed on the local network either using the
IP-Tool or directly in a web browser.
Accessing the Camera Using the IP-Tool
1. Make sure the camera and PC are connected to the LAN.
2. Locate the IP-Tool installer at www.
vitekcctv.com/Downloads/Soft-
ware/Transcendent-IPTool_v2.0.2.zip
, then install on the PC. Open
the installed application.
3. Modify the IP address. The default IP address is 192.168.226.201.
Click the information of the camera listed in the above table to show
the network information on the right side. Modify the IP address and
gateway of the camera and make sure its network address is in the
same local network segment as the computer’s. Please modify the
IP address of your device according to the practical situation.
For example, the IP address of your computer
is 192.168.13.4. So the IP address of the
camera shall be changed to 192.168.13.X.
After modification, please input the password
of the administrator and click “Modify” button
to modify the setting.
** Default admin password: “123456".

8 9
4. Double-click the IP address and then the system will pop up the web
browser to connect IP-CAM . IE browser will download the Active X
control. After downloading, a login window will pop up as shown
below:
Input the user name and password to log in.
Default user name: admin / Default password: 123456.
Directly Access Through a Web Browser
The default network settings are as shown below:
IP address: 192.168.226.201 HTTP: 80
Subnet Mask: 255.255.255.0 Data Port: 9008
Gateway: 192.168.226.1
You may use the above default settings when you log in the camera for
the first time.
1. Manually set the IP address of the PC. The network segment should
be the same as the default settings of IP-CAM. Open the network
and share center. Click “Local Area Connection” to pop up the
following window.
Select “Properties” and then select Internet protocol according to the
actual situation (for example: IPV4). Next, click “Properties” button to
set the network of the PC.

9
2. Open the IE Browser and input the default address of IP-CAM and
confirm. The IE browser will download Active X control.
3. After downloading Active X control, the login dialog box will pop up.
4. Input the default username and password and then enter to view.
WAN Configuration
Access the camera by the router or virtual server for example.
1. Make sure the camera is connected to the LAN; Then log into the
camera via LAN and go to System Congfig→Network Config→Port
menu to set up the port number.
2. Enter System Config→Network Config→IP Address menu to modify
the IP address.
4. Open the web browser and input its WAN IP and HTTP port to
access the IP-CAM.
3. Go to the router’s management interface through IE browser to
forward the IP address and port of IP-CAM in the “Virtual Server”.

10 11
Enable Face Detection
Click Config>Event>Face Detection to go to the Face Detection
Settings Interface. Check “Enable” to enable the function. For more
detailed settings / instructions, please refer to the use manual.
Temperature Measurement Settings
Click Config>Temperature>Temperature Measurement to go to the
temperature measurement settings interface.
1. Enable “Temperature Measurement”, select Celcius or Farenheit
termperature as needed, then set the high and low temp. threshold.
2. Set the alarm
holding time and
the alarm trigger
options.
3. Click “Save” to
save the settings.
Altri manuali per Transcendent 5 Series
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Vitek Telecamera IP

Vitek
Vitek Transcendent VT-TPTZ-B10X5N Manuale utente

Vitek
Vitek Transcendent Series Manuale utente

Vitek
Vitek VTC-C2NZ Manuale utente

Vitek
Vitek VTD-THD2RFE Manuale utente

Vitek
Vitek VTC-IRA24F Manuale utente

Vitek
Vitek VTC-IR303-212NP Manuale utente

Vitek
Vitek VTD-MS2810DN Manuale utente

Vitek
Vitek VTC-BHOCRAZE Manuale utente

Vitek
Vitek VTC-TNB5RFS/-2 Manuale utente

Vitek
Vitek VTD-IR2811DN Manuale utente