WIKA TF35 Manuale utente

ES
FR
DE
EN
Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
Threaded thermometer with plug connection, model TF35
Einschraubthermometer mit Steckeranschluss, Typ TF35
Capteur à visser avec connexion enfichable, type TF35
Termómetro para roscar con conector, modelo TF35
Fig. 1: AMP Junior Power Timer connector
Fig. 2: Circular connector M12 x 1
Fig. 3: Deutsch instrument connector DT04-2P
Fig. 4: Rectangular connector EN 175301-803

11442042.05 04/2020 EN/DE/FR/ES
ES
FR
DE
EN
2WIKA operating instructions model TF35
Operating instructions model TF35
Page 3 - 18
Betriebsanleitung Typ TF35
Seite 19 - 34
Mode d'emploi type TF35
Page 35 - 50
Manual de instrucciones modelo TF35
Página 51 - 65
© 01/2009 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!

11442042.05 04/2020 EN/DE/FR/ES
3
EN
WIKA operating instructions model TF35
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 7
4. Transport, packaging and storage 10
5. Commissioning, operation 11
6. Maintenance and cleaning 13
7. Dismounting, return and disposal 14
8. Specifications 16

11442042.05 04/2020 EN/DE/FR/ES
4
EN
WIKA operating instructions model TF35
1. General information
■
The threaded thermometer described in the operating instructions has been
designed and manufactured using state-of-the-art technology. All components
are subject to stringent quality and environmental criteria during production. Our
management systems are certified to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the
instrument. Working safely requires that all safety instructions and work instructions
are observed.
■
Observe the relevant local accident prevention regulations and general safety
regulations for the instrument's range of use.
■
The operating instructions are part of the product and must be kept in the immediate
vicinity of the instrument and readily accessible to skilled personnel at any time. Pass
the operating instructions on to the next operator or owner of the instrument.
■
Skilled personnel must have carefully read and understood the operating instructions
prior to beginning any work.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modifications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 67.10
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.de
1. General information

11442042.05 04/2020 EN/DE/FR/ES
5
EN
WIKA operating instructions model TF35
2. Design and function
2.1 Overview
Electrical connection
Process connection
Thermowell
2.2 Description
The model TF35 threaded thermometer is used for temperature measurement of liquid
and gaseous media.The temperature range depends on the measuring element.
The integrated thermowell with threaded connection enables direct installation into the
process. Depending on the requirements, the thermowell can be selected from brass
or stainless steel. By default, the TF35 thermometer can be used for pressures up to
50 bar [725 psi].
The directly mounted coupler connector ensures simple commissioning of the
thermometer.
All electrical components are protected against splash water.The electrical connection
is made via the connector.
The threaded thermometer model TF35 has a high resistance to shock and vibration.
2. Design and function

11442042.05 04/2020 EN/DE/FR/ES
6
EN
WIKA operating instructions model TF35
2. Design and function
2.3 Dimensions in mm
AMP Junior Power Timer
connector
FASTON blade terminal
6.3 x 0.8 mm
Circular connector M12 x 1
Deutsch instrument connector
DT04-2P
Circular connector M12 x 1
with neck tube 45 mm
Rectangular connector
EN 175301-803, form A
Bayonet connector,
DIN 72585
11398711.02
11507128.02
11507101.02
11507498.02
11488086.03
14073420.02
11578549.01

11442042.05 04/2020 EN/DE/FR/ES
7
EN
WIKA operating instructions model TF35
2.4 Scope of delivery
Cross-check scope of delivery with delivery note.
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious
injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries
or damage to property or the environment, if not avoided.
DANGER!
... identifies hazards caused by electric power. Should the safety
instructions not be observed, there is a risk of serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation that can result in burns,
caused by hot surfaces or liquids, if not avoided.
Information
... points out useful tips, recommendations and information for efficient
and trouble-free operation.
3.2 Intended use
The threaded thermometer model TF35 is used for temperature measurement in a wide
range of industrial applications. It is not intended to provide any safety or protective
functionality.
The instruments are not approved for use in hazardous areas!
The threaded thermometer has been designed and built solely for the intended use
described here, and may only be used accordingly.
2. Design and function / 3. Safety

11442042.05 04/2020 EN/DE/FR/ES
8
EN
WIKA operating instructions model TF35
The technical specifications contained in these operating instructions must be observed.
Improper handling or operation of the threaded thermometer outside of its technical
specifications requires the instrument to be taken out of service immediately and inspected
by an authorised WIKA service engineer.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use.
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous situations and
injuries.
▶
Refrain from unauthorised modifications to the instrument.
▶
Do not use the instrument within hazardous areas.
▶
Do not use the instrument with abrasive or viscous media.
Any use beyond or different to the intended use is considered as improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Responsibility of the operator
The instrument is used in the industrial sector.The operator is therefore responsible for
legal obligations regarding safety at work.
The safety instructions within these operating instructions, as well as the safety, accident
prevention and environmental protection regulations for the application area must be
maintained.
The operator is obliged to maintain the product label in a legible condition.
To ensure safe working on the instrument, the operating company must ensure
■
that suitable first-aid equipment is available and aid is provided whenever required.
■
that the operating personnel are regularly instructed in all topics regarding work
safety, first aid and environmental protection and know the operating instructions
and, in particular, the safety instructions contained therein.
■
that the instrument is suitable for the particular application in accordance with its
intended use.
■
that personal protective equipment is available.
3. Safety

11442042.05 04/2020 EN/DE/FR/ES
9
EN
WIKA operating instructions model TF35
3.5 Personnel qualification
WARNING!
Risk of injury should qualification be insufficient
Improper handling can result in considerable injury and damage to property.
▶
The activities described in these operating instructions may only be
carried out by skilled personnel who have the qualifications described
below.
▶
Keep unqualified personnel away from hazardous areas.
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be personnel
who, based on their technical training, knowledge of measurement and control
technology and on their experience and knowledge of country-specific regulations,
current standards and directives, are capable of carrying out the work described and
independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive
media.
3.6 Labelling, safety marks
Product label (example)
Model
Measuring element
Number of production order
Approval logos
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
TFS135 NC 60 °C 12345678
3. Safety

11442042.05 04/2020 EN/DE/FR/ES
10
EN
WIKA operating instructions model TF35
4. Transport, packaging and storage
4.1 Transport
Check the instrument for any damage that may have been caused by transport.
Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to property can occur.
▶
When unloading packed goods upon delivery as well as during
internal transport, proceed carefully and observe the symbols on the
packaging.
▶
With internal transport, observe the instructions in chapter 4.2
“Packaging and storage”.
If the instrument is transported from a cold into a warm environment, the formation of
condensation may result in instrument malfunction. Before putting it back into operation,
wait for the instrument temperature and the room temperature to equalise.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change
in installation site, sending for repair).
Permissible conditions at the place of storage:
■
Storage temperature: -40 ... +85 °C
■
Humidity: 35 ... 85 % relative humidity (no condensation)
Avoidance of exposure to the following factors:
■
Direct sunlight or proximity to hot objects
■
Mechanical vibration, mechanical shock (putting it down hard)
■
Soot, vapour, dust and corrosive gases
■
Hazardous environments, flammable atmospheres
Store the threaded thermometer in its original packaging in a location that fulfils the
conditions listed above. If the original packaging is not available, pack and store the
thermometer as described below:
1.
Wrap the instrument
in an antistatic plastic film.
2.
P
lace the instrument
, along with the shock-absorbent material, in the packaging.
3. If stored for a prolonged period of time (more than 30 days), place a bag containing a
desiccant inside the packaging.
4. Transport, packaging and storage
Indice
Lingue:
Altri manuali WIKA Termometro

WIKA
WIKA TR30 Manuale utente

WIKA
WIKA TRW Manuale utente

WIKA
WIKA Intelli Therm TGT73.100 Manuale utente

WIKA
WIKA CTH63I0 Manuale utente

WIKA
WIKA 53 Series Manuale utente

WIKA
WIKA TR57-M Manuale utente

WIKA
WIKA IntelliTHERM TGT73 Manuale utente

WIKA
WIKA TR33 Manuale utente

WIKA
WIKA CTH6300 Manuale utente

WIKA
WIKA TR33 Manuale utente

WIKA
WIKA TG58SA Istruzioni operative

WIKA
WIKA TR21 Manuale utente

WIKA
WIKA TR Series Manuale utente

WIKA
WIKA CTH 6450 Manuale utente

WIKA
WIKA TR21 Manuale utente

WIKA
WIKA TF-LCD Manuale utente

WIKA
WIKA TR36 Manuale utente

WIKA
WIKA TR25 (Ex i) Manuale utente

WIKA
WIKA 53 Series Manuale utente

WIKA
WIKA Twin-Temp 54 Manuale utente