WIKA S-20 Manuale utente

Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
GB
D
F
E
Pressure transmitter model S-20
Druckmessumformer Typ S-20
Pressure transmitter model S-20
Transmisor de presión modelo S-20
Transmetteur de pression type S-20

2 WIKA operating instructions pressure transmitter, model S-20
GB
D
14043170.01 04/2013 GB/D/F/E
F
E
Operating instructions model S-20 Page 3 - 24
Betriebsanleitung Typ S-20 Seite 25 - 48
Mode d'emploi type S-20 Page 49 - 70
Manual de instrucciones modelo S-20 Página 71 - 93
© 2013 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA® is a registered trademark in various countries.
WIKA® ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!

3WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
Contents
Contents
1. General information 4
2. Safety 6
3. Specications 9
4. Design and function 13
5. Transport, packaging and storage 14
6. Commissioning, operation 15
7. Zero point adjustment 20
8. Maintenance and cleaning 21
9. Faults 22
10. Dismounting, return and disposal 23
Appendix 1: EC Declaration of conformity model S-20 47
Declarations of conformity can be found online at www.wika.com.

4 WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
1. General information
1. General information
■
The pressure transmitter described in the operating instructions has been designed and manufactured using state-
of-the-art technology.
All components are subject to stringent quality and environmental criteria during
production. Our management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument. Working safely requires that
all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range
of use.
■
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and
readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
■
The manufacturer's liability is void in the event of any damage caused by using the product contrary to its intended
use, non-compliance with these operating instructions, assignment of insuciently qualied skilled personnel or
unauthorised modications to the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 81.61
- Application consultant: Tel.: (+49) 9372/132-8976
Fax: (+49) 9372/132-8008976
E-mail: [email protected]

5WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to the equipment or
the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and trouble-free operation.
WARNING!
... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces or liquids, if
not avoided.
Abbreviations
2-wire The two connection lines are used for the voltage supply.
The measurement signal also provides the supply current.
3-wire Two connection lines are used for the power supply.
One connection line is used for the measurement signal.
UBPositive power supply terminal
0V Negative power supply terminal
S+Positive output terminal
1. General information

6 WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate pressure transmitter has been
selected in terms of measuring range, design and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
■
Open the connections only after the system has been depressurised.
■
Observe the working conditions in accordance with chapter 3 "Specications".
Further important safety instructions can be found in the individual chapters of these operating instructions.
2.1 Intended use
The pressure transmitter is used to convert pressure into an electrical signal.
With hydrogen applications, use is only permitted when a medium and ambient temperature of 30 °C
is not exceeded.
For applications with direct contact with foodstus this pressure transmitter is not suitable.
The instrument has been designed and built solely for the intended use described here, and may only be used
accordingly.
The technical specications contained in these operating instructions must be observed. Improper handling or opera-
tion of the pressure transmitter outside of its technical specications requires the instrument to be taken out of service
immediately and inspected by an authorised WIKA service engineer.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
2. Safety

7WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who
have the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement
and control technology and on their experience and knowledge of country-specic regulations, current standards and
directives, are capable of carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids, and refrigeration
plants, compressors, etc., in addition to all standard regulations, the appropriate existing codes or
regulations must also be followed.
WARNING!
Residual media in dismounted pressure transmitters can result in a risk to persons, the environment and
equipment.
Take sucient precautionary measures.
2. Safety

8 WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
If the serial number becomes illegible due to mechanical damage or overpainting, traceability will no longer be
possible.
Explanation of symbols
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
2. Safety
2.4 Labelling / safety marks
Product label
Model
P# product number
S# serial number
Measuring range
Output signal
Power supply
Pin assignment see explanation of symbols

9WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
3. Specications
3. Specications
Permissible temperature ranges
Medium Ambient Version
-30 ... +100 °C -30 ... +100 °C -
-40 ... +125 °C -40 ... +125 °C -
-40 ... +150 °C -40 ... +125 °C 1) with cooling element
-40 ... +200 °C -40 ... +125 °C 1) with cooling element
-20 ... +60 °C -20 ... +60 °C Oxygen applications
1) Derating curve and formula
Depending on the choice of sealing on the process connection and the electrical connection, there may be limitations
in the medium and the ambient temperatures.
Ambient temperature [°C]
Medium temperature [°C]
Maximum permissible ambient temperature
Tamb (Tmed < 125 °C) = 125 °C
Tamb (Tmed ≥ 125 °C) = -0.62 x Tmed + 202 °C
Tamb = Ambient temperature [°C]
Tmed = Medium temperature [°C]
Maximum permissible medium temperature
Tmed (Tamb < 80 °C) = 200 °C
Tmed (Tamb ≥ 80 °C) = -1.61 x Tamb + 326 °C

10 WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
3. Specications
Electrical connection maximum permissible temperature
Angular connector DIN 175301-803 A -30 ... +100 °C
Angular connector DIN 175301-803 C -30 ... +100 °C
Circular connector M12 x 1 (4-pin) -30 ... +100 °C
Circular connector M12 x 1 (4-pin, metallic) -40 ... +125 °C (cULus: +85 °C)
Bayonet connector (6-pin) -40 ... +125 °C
Field case -25 ... +100 °C
Heavy-duty connector -40 ... +125 °C
Cable outlet IP 67 -30 ... +100 °C
Cable outlet ½ NPT conduit -30 ... +100 °C (cULus: +90 °C)
Cable outlet IP 68 -30 ... +125 °C (cULus: +90 °C)
Cable outlet IP 68, FEP -40 ... +125 °C (cULus: +105 °C)
Cable outlet IP 69K -30 ... +125 °C (cULus: +90 °C)
Climate class
Storage: 1K3 (per EN 60721-3-1)
Transport: 2K2 (per EN 60721-3-2)
Operation: 4K4H (per EN 60721-3-4, without condensation or icing)
Vibration resistance (per IEC 60068-2-6)
20 g, 10 ... 2,000 Hz, (40 g, 10 ... 2,000 Hz for heavy-duty connector)
For instruments with cooling elements a limited vibration resistance applies 10 g (10 ... 2,000 Hz)
Continuous vibration resistance (per IEC 60068-2-6)
10 g
Shock resistance (per IEC 60068-2-27)
100 g, 6 ms (500 g, 1 ms for heavy-duty connector)
Free-fall test (following IEC 60721-3-2)
Individual packaging: 1.5 m
Multiple packaging: 0.5 m
PE bag: 0.5 m
Altri manuali per S-20
1
Indice
Lingue:
Altri manuali WIKA Trasmettitore

WIKA
WIKA N-10 Manuale utente

WIKA
WIKA TIF11 Manuale utente

WIKA
WIKA DPT-20 Manuale utente

WIKA
WIKA HP-1 Manuale utente

WIKA
WIKA OT-1 Manuale utente

WIKA
WIKA UPT-20 Manuale di installazione

WIKA
WIKA T24.10 Manuale utente

WIKA
WIKA E-10 Manuale utente

WIKA
WIKA IPT-10 Manuale utente

WIKA
WIKA DMSU22SA Manuale utente

WIKA
WIKA CPT-2x series Manuale utente

WIKA
WIKA LH-20 Istruzioni per l'installazione

WIKA
WIKA T53.10 Foglio di istruzioni

WIKA
WIKA S-10 Manuale utente

WIKA
WIKA D-20-9 Manuale utente

WIKA
WIKA A-10 Manuale utente

WIKA
WIKA CPT-2 series Guida utente

WIKA
WIKA SA-11 Manuale utente

WIKA
WIKA AC-1 Manuale utente

WIKA
WIKA FLM-CAI Manuale utente