Temperature transmitter, model T24.10
Temperature transmitter, model T24.10
Temperatur-Transmitter, Typ T24.10

2
2370242.09 08/2013 GB/D
WIKA operating instructions temperature transmitter, model T24
© 2011 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
D
GB Operating instructions model T24.10
Page 3 - 32
Betriebsanleitung Typ T24.10
Seite 33 - 62
Further languages can be found at www.wika.com.

GB
1. General information 4
2. Safety 6
3. Specications 11
4. Design and function 12
5. Transport, packaging and storage 12
6. Commissioning, operation 14
7. T24 conguration software WIKA_TT 21
8. Information on mounting and operation in
hazardous areas (Europe) 23
9. Further country-specic approvals 27
10. Maintenance 28
11. Faults 28
12. Return and disposal 30
Appendix 1: FM installation drawing 31
Appendix 2: EC declaration of conformity 32
WIKA operating instructions temperature transmitter, model T24 3
2370242.09 08/2013 GB/D
Contents
Contents
Declarations of conformity can be found online at www.wika.com.

GB
4 WIKA operating instructions temperature transmitter, model T24
2370242.09 08/2013 GB/D
1. General information
■
The temperature transmitter described in the operating instructions
has been manufactured using state-of-the-art technology. All
components are subject to stringent quality and environmental
criteria during production. Our management systems are certied to
ISO 9001 and ISO 14001.
■
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
■
Observe the local accident prevention regulations and general
safety regulations, in eect for the instrument's range of use.
■
The operating instructions are part of the product and must be kept
in the immediate vicinity of the instrument and readily accessible to
skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
■
The manufacturer‘s liability is void in the case of any damage
caused by using the product contrary to its designated use,
non-compliance with these operating instructions, assignment
of insuciently qualied skilled personnel or unauthorised
modications to the instrument.
■
The general terms and conditions, contained in the sales
documentation, shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 24.01
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
1. General information

GB
WIKA operating instructions temperature transmitter, model T24 5
2370242.09 08/2013 GB/D
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can
result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can
result in light injuries or damage to equipment or the
environment, if not avoided.
Information
… points out useful tips, recommendations and informati-
on for ecient and trouble-free operation.
DANGER!
...identies hazards caused by electrical power. Should
the safety instructions not be observed, there is a risk of
serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation in a poten-
tially explosive atmosphere, resulting in serious injury or
death, if not avoided.
1. General information

GB
6 WIKA operating instructions temperature transmitter, model T24
2370242.09 08/2013 GB/D
2. Safety
WARNING!
Before installation, commissioning and operation, ensure
that the appropriate temperature transmitter has been
selected in terms of measuring range, design and specic
measuring conditions.
Non-observance can result in serious injury and/or
damage to the equipment.
WARNING!
This is a Class A product. In a domestic environment this
product may cause radio interference in which case the
user may be required to take adequate measures.
EMC directive 2004/108/EC, EN 61326 Emission
(Group 1, Class A) and Immunity (industrial locations)
Further important safety instructions can be found in the
individual chapters of these operating instructions.
2.1 Intended use
The temperature transmitter T24.10 is a congurable transmitter for
use with resistance thermometers (RTD) and resistance sensors.
The temperature transmitter has been designed and built solely for the
intended use described here, and may only be used accordingly.
The technical specications contained in these operating instructions
must be observed. Improper handling or operation of the instrument
outside of its technical specications requires the instrument to be
taken out of service immediately and inspected by an authorised
WIKA service engineer.
2. Safety

GB
WIKA operating instructions temperature transmitter, model T24 7
2370242.09 08/2013 GB/D
If the instrument is transported from a cold into a warm environment,
the formation of condensation may result in instrument malfunction.
Before putting it back into operation, wait for the instrument
temperature and the room temperature to equalise.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
2.2 Personnel qualication
WARNING!
Risk of injury if qualication is insucient!
Improper handling can result in considerable injury and
damage to equipment.
■
The activities described in these operating instructions
may only be carried out by skilled personnel who have
the qualications described below.
■
Keep unqualied personnel away from hazardous
areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on
their technical training, knowledge of measurement and control
technology and on their experience and knowledge of country-specic
regulations, current standards and directives, are capable of carrying
out the work described and independently recognising potential
hazards.
Special operating conditions require further appropriate knowledge,
e.g. of aggressive media.
2. Safety

GB
8 WIKA operating instructions temperature transmitter, model T24
2370242.09 08/2013 GB/D
2.3 Additional safety instructions for instruments per ATEX
WARNING!
Non-observance of these instructions and their contents
may result in the loss of explosion protection.
WARNING!
■
Observe the applicable regulations for the use
of Ex-class instruments (e. g.: EN 60079-0:
2006, EN 60079-11: 2007, EN 60079-26: 2007,
EN 60079-27: 2006 + 2008, EN 61241-0: 2006,
EN 61241-11: 2006, EN 60079-15: 2005).
■
Do not use transmitters with any damage to the exterior!
■
Do not congure the transmitter, programming unit
(PU-448) and PC in hazardous areas!
2.4 Special hazards
WARNING!
Observe the information given in the applicable type
examination certicate and the relevant country-
specic regulations for installation and use in potentially
explosive atmospheres (e.g. IEC 60079-14, NEC, CEC).
Non-observance can result in serious injury and/or
damage to the equipment.
For additional important safety instructions for instruments
with ATEX approval, see chapter 8 “Information on
mounting and operation in hazardous areas (Europe)”.
WARNING!
For hazardous media such as oxygen, acetylene,
ammable or toxic gases or liquids, and refrigeration
plants, compressors, etc., in addition to all standard
regulations, the appropriate existing codes or regulations
must also be followed.
2. Safety

GB
WIKA operating instructions temperature transmitter, model T24 9
2370242.09 08/2013 GB/D
WARNING!
Protection from electrostatic discharge (ESD) required.
The proper use of grounded work surfaces and personal
wrist straps is required when working with exposed
circuitry (printed circuit boards), in order to prevent static
discharge from damaging sensitive electronic components.
To ensure safe working on the instrument, the operating
company must ensure
■
that suitable rst-aid equipment is available and aid is
provided whenever required,
■
that the operating personnel are regularly instructed
in all topics regarding work safety, rst aid and
environmental protection and knows the operating
instructions and, in particular, the safety instructions
contained therein.
DANGER!
Danger of death caused by electric current
Upon contact with live parts, there is a direct danger of
death.
■
Electrical instruments may only be installed and
connected by skilled electrical personnel.
■
Operation using a defective power supply unit (e.g.
short circuit from the mains voltage to the output
voltage) can result in life-threatening voltages at the
instrument!
WARNING!
Residual media in dismounted instruments can result in
a risk to persons, the environment and equipment.Take
sucient precautionary measures.
Do not use this instrument in safety or Emergency Stop
devices. Incorrect use of the instrument result in injury.
2. Safety

GB
10 WIKA operating instructions temperature transmitter, model T24
2370242.09 08/2013 GB/D
Should a failure occur, aggressive media with extremely
high temperature and under high pressure or vacuum may
be present at the instrument.
2.5 Labelling / safety marks
Product label
Output signal
Power supply
Permissible ambient temperature
Pin
assignment
Year of manufacture
Sensor, Pt100
or RTD
Model
Explanation of symbols
Before mounting and commissioning the instrument,
ensure you read the operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant
European directives.
ATEX European Explosion Protection Directive
(Atmosphère = AT, explosible = EX)
Instruments bearing this mark comply with the
requirements of the European Directive 94/9/EC (ATEX)
on explosion protection.
2. Safety
Altri manuali per T24.10
1
Indice
Lingue:
Altri manuali WIKA Trasmettitore

WIKA
WIKA S-10 Manuale utente

WIKA
WIKA UPT-20 Manuale utente

WIKA
WIKA S-11 Manuale utente

WIKA
WIKA IPT-2 Series Manuale utente

WIKA
WIKA SL-1 Manuale utente

WIKA
WIKA M-10 Manuale utente

WIKA
WIKA UPT-2 Series Manuale utente

WIKA
WIKA CPT-2x series Manuale utente

WIKA
WIKA A-10 Manuale utente

WIKA
WIKA A-10 Manuale utente