Xiamen BT01 Manuale utente

USERMANUAL
BT01/BT02/BT03/BT04
JOHNLEE
COMPANYNAME@COPYRIGHT2020INCHINA

TheDistanceMonitoringBracelet(aliasnamesuchasdistance
Reminder,Protector,SmartDistanceAlert,SocialDistance
Reminder,SmartWristband,DistanceTraceBracelet,Smart
DistanceKeeper,KeyfobDistanceReminder,NeckletDistance
Reminder)especiallydesignedtoavoidclosingsocialcontact
fromanyonetotheothers,futurefunctionofthedeviceisfor
systemIntegratorstodevelopcloudapplicationforthecivilianin
ordertoguaranteeandmovementtraceabilityofcivilian(most
areworkers,employees&students)stayingatasafesocial
distancefromanytwoofclosingpeoplesandawayfrominfector
ofdisease.
BasingonLEDlightindicatorandvibrationnotice,anyoftwo
closingpeopleswillberemindedtoeachotherinrealtime.
Keypointistoinstructpeoplemoveawayfrompotentialdisease
andtraceabilityinthefuture.
NOTE:Thisdocumentisconstantlyupdatedandistherefore
subjecttochange.

ProductFeature
RealTimeDistanceMonitor/trackwithinaradiusof200cmanddetectionanglemorethan
100degreeauto‐detectionofclosingcontact(dependsonconfigurable)
OperatingFrequency:2.41Ghz‐BluetoothLowEnergyBLE5,5dBmmaximumPower
DetectionAccuracy:±30cm(dependsonenvironment)
DetectionInterval:1.5secondindefault(configurable1‐30)
DetectionThreshold:83dBmindefault(configurable70‐96)
Dimension(BT01):38(L)*30(W)*13mm(H)(body)/260(L)*36(W)*16.6mm(H)withstrap
Dimension(BT02‐BT04):47(L)*18(W)*11mm(H)withoutwristband
NetWeight:38.3g/BT01,20g/BT02‐BT03,28g/BT04
Color:Blackindefault(Blue/Orange/othersisoptionalonabovepicture)
Material:PC+SiliconTPE
PowerConsumption:Continueworking40days&replaceableCR2477battery
Continueworking5‐7days&rechargeablelithiumbattery90mA
Indicator:ClosingAlarm,Power&RechargewithLEDlight&Vibrator(Beeperisoptional)
TemperatureMeasurement:350C‐420C(ModelBT03oraboveonly)
Display:0.42inchOLED(ModelBT04oraboveonly)
PNPdevicewithoutappsorwithspecialinfrastructureandApps
Upto10240RecordsofclosingcontactcanbesavedanduploadedviaAPP/Gateway
infrastructure.

QuickOperation
STEP1:SwitchonBatterySupply(BT01requiredonly)
Thereis2optionseithertoremovetheprotectionfilmfrombatteryoropen
housingandcorrectbatteryinstallation
1stoption:RemoveTransparent
Protection/IsolationFilmfromthe
cornergapofdevice(nearby“”
button).ThefunctionofIsolationfilm
istonotdraindownbatterylifeduring
logisticsbeforeuse.
2ndoption:Opendevicehousingand
correctthebatteryplacementfromup
todown,refertothe“BatteryOperation”
Note:Whilethebatteryispoweredtothedevice,LEDlightfromdevicewillblink
lightfor5secondsimmediatelyandruninclosingdetectionautomaticallytotrack
thepotentialclosingdeviceandrecordintoitsmemory..
STEP2:PoweronDevice
Foranewdevice,keeptouching“”
Buttonfor8secondstoswitchon
braceletandensureitwillblinkLEDlight
andvibratingfor2or3times.

STEP3:DeviceRegistration
EachdevicewillbeboundedwithaNickName,LoginID(PersonalIDorMACaddress)
andpassword(Defaultis123456)thenassignedtotheendcustomer.Thisprocess
canbemadebyyouradministrator,ordoitbyyourselfviaourClientAPPasbelow
APPInstructionmentioned.Withoutregistrationofeachbracelet,closingdatawill
justrecordMACaddressofthedevice.
STEP4:WearingDevice&FollowMovementInstructionAwayfrom
ClosingContact
Everybraceletwaswith
enoughbatterylifeand
keepworkingproperly
foryouremployees,
workers,orstudents,
instructpeopletoawayfromothersduringworking/studying
STEP5:UploadingClosingContactViaGateway
Sinceeachbraceletwillrecordnomorethan10240closingcontacts,the
suggestionistouploaddataeverytimefromGatewayentrance/exitasbelow
GatewayAPPmentioned
FinalSTEP6:QueryClosingContact
AnypeopleallowtochecktheirclosingcontactbyClientApporPlatform.

MovementInstruction&DistanceMeasurement
Distancemeasurementwithclosingalarmsforany2closingdevicesisabout
150cm,theclosingalarmisLEDblinkingandvibrating
ProhibitedMovement
Theabovespecificscenewithvisualmovement(parallel,straightmeet,facing
meetandlinefollowstraightly)mustbeprohibitedasthemovementsiswith

knownrisky.Thedevicehaslimiteddetectionaccuracyasbelowsignalcoverability
graph
BT01BT02/03/04NewBT04with15.9transmission
Areliable/conformablewearingstyleismostimportancethantheotherssince
differentwearinghasdifferentmeasurement&detectionperformance.
DistanceDescription
1) Socialdistancemustbekeptabove1.5meter,otherwisedevicewillalarmfrom
onetotheothers
2)Safedistanceatleast0.5meterasthisisminimumrequirement.
3)Directdistanceshouldbediagonaldistancewith2.0meters+

StandardMovementMeasurement(Basingon“EchoFree”Test)
KnownvariantmeasurementisduetoRFnoisessuchasreflection,shadow,
resistantandsoon,soStandardmovementtestisrecommendedinanECO‐FREE
chamber,thealarmdistanceofmeasurementisaround1.8m‐1.9meter.
MovementInstruction,remindpeopleawayfromclosingcontacts
Alarmdistanceisabout0.5‐2.0meterwhile
Peoplelinefollowasrightpictureduetobody
disturbanceoccursfortheRFsignal
Alarmdistanceisabout0.5‐1.5meter
Whilepeoplestay/walkingparallelly
Duetobodyandbodysize

Asdetectionrange&angleisinfluencedbyinfrastructurereflection,shadowand
bodydisturbanceoccurs,thedetectedsocialdistancewillbemorethan0.3meter
variantduetohugeman,slimgirlsanddifferentsizeofhumanbody.
VS
Anytwomovementsarewalkingtogethercloselyasbelow,thealarmdistance
(socialdistance)isabout1.9meters

Belowcase,staticsocialdistancewillbemorethan2.5meter.
Belowcaseswitha90degreedirectionoftwomovements,thealarmofsocial
distanceisaround1.8meters
MovementGuideline
MovementGuideline
SocialDistance
Questo manuale è adatto per i seguenti modelli
3
Indice

















