AEMC 5100 Manuale utente

5000V Megohmmeters
Models 5000N/5100/5110
USER MANUAL
0
1
0
0
2
0
0
3
0
0
4
0
0
5
0
0
6
0
3
0
k
2
0
k
1
0
k
5
k
2
k
1
0
0
0
5
0
0
2
0
0
1
0
0
5
0
2
0
1
3
5
1
0
2
0
5
0
1
0
0
2
0
0
5
0
0
1
0
0
0
2
k
3
k
G
Ω
M
Ω
k
Ω
V
5
3
0
5
0
1
0
0
2
0
0
5
0
0
1
0
0
0
2
k
5
k
1
0
k
2
0
k
3
0
k
5
0
0
V
1
0
0
0
V
2
5
0
0
V
5
0
0
0
V
M
Ω
G
Ω
M
Ω
G
Ω
M
Ω
G
Ω
M
Ω
G
Ω
k
Ω
3
3
µ
A
m
a
x
.
1
3
0
0
V
(
)


Limited Warranty
The Megohmmeters Model 5000N, 5100 and 5110 are warranted to the
owner for a period of 2 years from the date of original purchase
against defects in manufacture. This limited warranty is given by
AEMC® Instruments, not by the distributor from whom it was pur-
chased. This warranty is void if the unit has been tampered with, abused
or if the defect is related to service not performed by AEMC® Instruments.
For full and detailed warranty coverage, please read the Warranty
Coverage Information, which is attached to the Warranty Registration
Card (if enclosed) or is available at www.aemc.com. Please keep the
Warranty Coverage Information with your records.
What AEMC®Instruments will do:
If a malfunction occurs within the warranty period, you may return the
instrument to us for repair, provided we have your warranty registration
information on file or a proof of purchase. AEMC® Instruments will, at its
option, repair or replace the faulty material.
REGISTER ONLINE AT:
www.aemc.com
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
First, request a Customer Service Authorization number (CSA#) by phone or
by fax from our Service Department (see address below), then return the
instrument along with the signed CSA Form. Please write the CSA number
on the outside of the shipping container. Return the instrument, postage or
shipment pre-paid to:
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
Service Department
15 Faraday Drive • Dover, NH 03820 USA
Tel: (800) 945-2362 (Ext. 360)
(603) 749-6434 (Ext. 360)
Fax: (603) 742-2346 or (603) 749-6309
Caution: To protect yourself against in-transit loss, we recommend you
insure your returned material.
Note: You must obtain a CSA# before returning any instrument.

- 2 -
Table of Contents
Warning ......................................................................................4
International Electrical Symbols .................................................4
Megohmmeter Model 5000N....................................................5
Receiving Your Shipment.....................................................5
Ordering Information ............................................................5
Accessories And Replacement Parts...................................5
Description ...........................................................................6
Specifications .......................................................................7
Control & Connector Identification .......................................9
Battery Replacement..........................................................10
AC Supply Module .............................................................10
Megohmmeter Model 5100/5110............................................11
Receiving Your Shipment...................................................11
Ordering Information ..........................................................11
Accessories And Replacement Parts.................................11
Description .........................................................................12
Specifications - Model 5100 ...............................................13
Specifications - Model 5110 ...............................................15
Control & Connector Identification .....................................17
AC Supply Module .............................................................18
Disassembly.......................................................................19
Using the Clock/Timer........................................................20
Operation: Models 5000N, 5100 & 5110................................22
The Analog Scale...............................................................22
Preliminary Check ..............................................................23
How to use the Push-To-Test Button.................................23
Utilizing the Guard Terminal...............................................24
Voltage Measurements (Safety Check) .............................25
Audible Signal ....................................................................26
Precautions when making DC Insulation Tests .................27
Insulation Measurement - Connections .............................27
Insulation Resistance Measurements on Motors...............30

- 3 -
Understanding Insulation Testing ........................................32
Ratio Testing ......................................................................33
Types of Tests....................................................................34
Spot Reading Test .............................................................34
Polarization Index...............................................................35
Step Voltage Test...............................................................36
The Effects of Temperature ...............................................37
Interpreting the Results ......................................................38
Maintenance............................................................................39
Warning..............................................................................39
Cleaning .............................................................................39
Repair And Calibration...........................................................40
Technical And Sales Assistance...........................................40

Megohmmeter Models 5000N/5100/5110
- 4 -
Warning
These safety warnings are provided to ensure the safety of
personnel and proper operation of the instrument.
WARNING: HIGH VOLTAGE PRESENT
•Do not attempt to perform any tests with these instruments
until you have read the instruction manual.
•Safety is the responsibility of the operator!
•Tests are to be carried out only on non-energized circuits!
Check for live circuits before making resistance measure-
ments (safety check).
•These Megohmmeters are sources of high voltage, as is the
sample connected to them. All persons performing or
assisting in the tests must employ all safety precautions to
prevent electrical shock to themselves and to others.
•AEMC® considers the use of rubber gloves to be an excellent
safety practice even if the equipment is properly operated and
correctly grounded.
•When testing capacitance samples, make sure that they have
been properly discharged and that they are safe to touch.
Dielectric insulation samples should be short-circuited for at
least five times the amount of time they were energized.
•Megohmmeters should never be used in an explosive
environment.
•Use the leads supplied with the megohmmeters. If they are
defective or worn, replace before testing.
International Electrical Symbols
This symbol signifies that the instrument is protected by double
or reinforced insulation. Use only specified replacement parts
when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer
to the user manual before using the instrument.
Risk of electric shock. The voltage at the parts marked with this
symbol may be dangerous.

Megohmmeter Models 5000N/5100/5110
- 5 -
MEGOHMMETER MODEL 5000N
Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are
consistent with the packing list. Notify your distributor of any missing
items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed
description of any damage.
Ordering Information
Megohmmeter Model 5000N................................................ Cat. #186.100
Includes megohmmeter, eight 1.5V “AA” batteries, one shielded lead,
two color-coded safety leads, insulated alligator clip, test probe
batteries,spare fuse, carrying case and user manual.
Accessories and Replacement Parts
AC power supply module with line cord and plug
for switch-selectable 110/220VAC at 47 to 400Hz................ Cat. #100.142
Protective rubber case with handle, safety yellow ............... Cat. #2980.02
Fuse, set of five, 0.1A slow blow
for AC supply module...........................................................Cat. #100.438
Fuse, set of one, 0.3A ..........................................................Cat. #100.429
Replacement lead, (green and blue clips) ........................... Cat. #1017.23
7-pin shielded lead, 10 ft
for Models 1000N/5000N/5100 ............................................ Cat. #2950.10
Probe and clip for Model 1000N/5000N............................... Cat. #100.404

Megohmmeter Models 5000N/5100/5110
- 6 -
Description
AEMC® Instruments Model 5000N (Cat. #186.100) is a portable, multi-
range, high-sensitivity megohmmeter capable of measuring a wide range
of insulation resistances from 10 kilohms to 3000 gigohms (3,000,000
megohms). The Model 5000N has four test voltages of 500, 1000, 2500,
and 5000 volts. Each test voltage setting has two overlapping resistance
ranges of 30MΩ to 30,000MΩ and 3GΩ to 3000GΩ on a long (9.4") dial.
In addition, the Model 5000N has a unique low insulation test range of 10
to 30,000kΩ with a constant current of 33µA (maximum voltage of
1300VDC), which is useful for testing old or flooded installations. A
voltmeter (safety check) with a range of 0 to 600 volts is standard.
The Model 5000N may be powered by either AC or DC. DC power is
supplied by eight 1.5V alkaline “AA” batteries. As an option, an AC line
supply module and cord for 110/220VAC at 47 to 400Hz can be inserted
in the battery compartment.
An audible signal, consisting of approximately ten beeps per minute, is
present when the megohmmeter is ON, and serves as a time base for
tests of long duration. A green LED, when ON, indicates that the
batteries are good when the push-to-test button is depressed. It also
serves as a warning light when the instrument is in use, indicating that
the selected test voltage is present at the terminals.

Megohmmeter Models 5000N/5100/5110
- 7 -
Specifications
INSULATION TESTS
DC Test Voltages:
500, 1000, 2500, 5000V
Megohm Ranges:
For each test voltage two direct reading ranges:
30 to 30,000MΩ
3 to 3000GΩ
(3000 to 3,000,000MΩ)
Short Circuit Current: 3mA (max)
Accuracy: 5% of reading typical
Charging Time:
MΩ range: 0.3 seconds/µF
GΩ range: 3 seconds/µF
Discharging Time:
Automatic discharge when test button is released; 0.1 seconds/µF
Scale:
Two large overlapping scales: 4.7" (119 mm) for each range
Test Voltage Generation:
Solid state circuitry generating rated test voltage across the full range
RESISTANCE TESTS
Test Current: Constant 33 µA DC
Kilohm Range: 10 to 30,000kΩ (30MΩ)
Maximum Test Voltage: 1300VDC
Accuracy: 5% of reading typical
VOLTAGE TESTS (SAFETY CHECK)
Voltage Range: 0 to 600VAC/DC
Accuracy: 3% of full scale

Megohmmeter Models 5000N/5100/5110
- 8 -
GENERAL SPECIFICATIONS
Audible Test Signal:
Ten beeps per minute
Power Supply:
Eight 1.5V “AA” alkaline batteries (NEDA 15A). Typical battery life: 350
one-minute tests; power consumed only when test button is depressed;
built-in battery check by green LED.
Option:
110/220V selectable
47 to 400Hz AC supply module
Dielectric Test: 4000VAC, 60Hz, 1 minute
Fuse Protection:
0.3A high interrupting capacity fuse between line and guard terminals
Meter Movement: Rugged taut band suspension
Dimensions: 7.7 x 5.2 x 3.75" (196 x 132 x 95mm)
Weight: 2.2 lbs (1 kg)
Temperature Range: 23° to 122°F (-5° to +50°C)
Case: High impact gray polycarbonate
Terminals:
Color-coded safety terminals; guard terminal eliminates surface
leakage errors
Electromagnetic Compatibility:
CEI 801-2: Electrical Discharge
Class II
CEI 801-3: Magnetic Fields 3 V/m
CEI 801-4: Rapid Transients Class II
CEI 801-5: Electrical Shock (5KV 2 Joules)
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali AEMC Strumento di misura

AEMC
AEMC MN250 Manuale utente

AEMC
AEMC SL261 Manuale utente

AEMC
AEMC DTR 8510 Manuale utente

AEMC
AEMC MN306 Manuale utente

AEMC
AEMC 6526 Manuale utente

AEMC
AEMC PowerPad IV Manuale utente

AEMC
AEMC 1510 Manuale utente

AEMC
AEMC MN379T Manuale utente

AEMC
AEMC PowerPad 8435 Guida all'installazione

AEMC
AEMC MN379 Manuale utente

AEMC
AEMC 4500 Manuale utente

AEMC
AEMC MN375 Manuale utente

AEMC
AEMC MD301 Manuale utente

AEMC
AEMC MN124 Manuale utente

AEMC
AEMC JM830A Manuale utente

AEMC
AEMC 5050 Manuale utente

AEMC
AEMC JM810A Manuale utente

AEMC
AEMC MN03 Manuale utente

AEMC
AEMC 500 Manuale utente

AEMC
AEMC OX 5022-CK Guida all'installazione