AEMC CL601 Manuale utente

ENGLISH User Manual
SIMPLE LOGGER®II
TRMS CLAMP-ON MODEL
CL601
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer.
Serial #: ________________________________
Catalog #: 2126.01
Model #: CL601
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Table of Contents
1. INTRODUCTION............................................................................... 3
1.1 International Electrical Symbols................................................3
1.2 DenitionofMeasurementCategories .....................................4
1.3 ReceivingYourShipment..........................................................4
1.4 OrderingInformation.................................................................4
2. PRODUCT FEATURES ...................................................................... 5
2.1 Description................................................................................5
2.2 ControlFeatures .......................................................................6
3. SPECIFICATIONS............................................................................. 8
3.1 Electrical ...................................................................................8
3.2 Mechanical................................................................................9
3.3 Environmental...........................................................................9
3.4 Safety........................................................................................9
4. OPERATION .................................................................................. 10
4.1 LEDControlOperationandStatusFunction ..........................10
4.2 ConnectingtheSimpleLogger®IItoaComputer ...................12
4.3 TurningtheUnitOn.................................................................12
4.4 RecordingData.......................................................................13
4.4.1 StartingaRecordingSession .....................................13
4.4.2 StoppingaRecordingSession ...................................13
4.5 DownloadingRecordedData..................................................13
4.6 ClearingAlarmIndication........................................................14
4.7 ErasingDatafromMemory.....................................................14
4.8 DataStorage...........................................................................15
4.8.1 TrendMeasurements..................................................15
4.9 NormalOperation ...................................................................15
4.10ResetSwitchOperation ..........................................................18
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

5. MAINTENANCE ............................................................................. 19
5.1 ChangingtheBatteries ...........................................................19
APPENDIX A: TROUBLESHOOTING...................................................... 20
APPENDIX B: GLOSSARY.................................................................... 21
Limited Warranty ...................................................................................23
WarrantyRepairs...................................................................................23
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Simple Logger®II Model CL601
3
CHAPTER 1
INTRODUCTION
WARNING
Thesesafetywarningsareprovidedtoensurethesafetyofpersonnel
andproperoperationoftheinstrument.
• Readtheinstructionmanualcompletelyandfollowallthesafetyinfor-
mationbeforeattemptingtouseorservicethisinstrument.
• Neverexceedthemaximumworkingvoltageratingsgiven.
• NEVERopenthebackoftheinstrumentwhileconnectedtoanycircuit
orinput.
• Always inspect the instrument accessories and leads prior to use.
Replaceanydefectivepartsimmediatelywithfactoryparts.
1.1 International Electrical Symbols
Signifies that the instrument is protected by double or reinforced insulation.
Indicates a WARNING and that the operator must refer to the user manual for instructions
before operating the instrument. Failure to follow or carry out any instructions preceded
by this symbol in the user manual may result in personnel injury or damage to the
instrument and installations.
Risk of electric shock. The voltage at parts marked with this symbol may be dangerous.
Refers to a type A current sensor. This symbol signifies that application around and
removal from HAZARDOUS LIVE conductors is permitted.
Refers to a type B current sensor. Do not apply around or remove from HAZARDOUS
LIVE conductors without additional protective means (de-energizing the circuit or
wearing protective clothing suitable for high voltage work).
In conformity with WEEE 2002/96/EC
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

4
Simple Logger®II Model CL601
1.2 Definition of Measurement Categories
Cat. I: For measurements on circuits not directly connected to theAC
supplywalloutletsuchasprotectedsecondaries,signallevel,and
limitedenergycircuits
Cat. II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
Cat. III:For measurements performed in the building installation at the
distributionlevelsuchasonhardwiredequipmentinxedinstalla-
tionandcircuitbreakers.
Cat. IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
with the packing list. Notify your distributor of any missing items. If the
equipmentappearstobedamaged,leaclaimimmediatelywiththecarrier
and notify your distributor at once, giving a detailed description of any
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering Information
Simple Logger®II Model CL601...................................... Cat. #2126.01
(1-Channel,TRMSClamp-on600AAC)
Includes USB cable, DataView®CD-ROM, 2x1.5V AA-cell alkaline batteries, user manual
and warranty card.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Simple Logger®II Model CL601
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheSimpleLogger® IIModelCL601 isabattery powered,onechannel
recordingdevicewithanalkalinebatterypack.Linetrackingisperformed
suchthat64samplesoveronelinecyclearetaken.Frequencytrackingis
performedovertherangeof±2Hzaroundthenominallinefrequency(50
or60Hz).Harmonicmeasurementsarecalculatedfromthese64samples
(HarmonicsareonlyavailablefromtheSimpleLogger®II Control Panel
withintheDataView®application).
TheSimpleLogger®IIrecordsTRMS ata rate ofup to eighttimes per
second.Themeasurementprocessisperformednomorethaneighttimes
persecond.TRMScalculationsareperformedonasinglelinecycle.This
meansthattheinput(s)areignoredbetweenmeasurementintervals.
The main advantage of the logger is its ability to perform a variety of
recording tasks with easy and intuitive setup from a computer using
DataView®software.
Analog information on the input is sampled and converted to a digital
signal. This digital signal isprocessed and stored along with scale and
time information. An optically isolated Universal Serial Bus (USB) port
providesforthetransferofdatafromtheinstrument’sinternalmemoryto
thecomputerforanalysis.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

6
Simple Logger®II Model CL601
2.2 Control Features
1
2
3
Figure 2-1. Key Components and Features
1. Control Button (PRESS)
Thisbuttonmarked“PRESS”selectsthemodeofoperation.Usethis
buttontostartorstoprecordings,erasethememory,clearalarmsand
turntheinstrumentON/OFF.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Simple Logger®II Model CL601
7
2. Five LED Indicators
The LEDs on the instrument serve two functions: control operation
andstatusfunction.
The control operation (function when holding down the PRESS•
button)isindicatedwithtexttotheleftofeachLED.
Thestatusfunction(functionwhenPRESSisnotbeinghelddown)•
associatedwitheachLEDisindicatedwithtexttotherightofeach
LED.
Referto§4.1fordetaileddescriptionsofeachLED.•
3. Female Type Mini-B USB Connector
4. Reset Button (not shown)
TheRESETbuttonresetstheCPUandislocatedinthebatterycom-
partment To access this button, remove the battery compartment
cover,thenresettheinstrumentbyinsertingasmalltool(suchasa
paperclip)throughtheholeinthecasetoactivateit.
5. Flash Upgrade Switches (not shown)
Thesetwoswitches(accessiblefromunderthebatterycompartment),
alongwiththeRESETbutton(andPCsoftware),areusedtorecover
fromafailedashupgradeprocedure.
WARNING: If the RESET button is pressed when the logger is recording, it will
stop recording and data in memory may be lost.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

8
Simple Logger®II Model CL601
CHAPTER 3
SPECIFICATIONS
3.1 Electrical
ReferenceConditions:23°C±3°C,30-50%RH,DCor50/60Hz,noACexternalmagneticeld,DC
magneticeld≤40A/m,centeredconductor,batteryvoltage:3V±10%.
MODEL CL601
Channels One
Input Split CT – AC Current
Current Range 0 to 600AAC
Resolution 0.1A
Accuracy
(50/60Hz)
0 to 5A: Unspecified
5 to 50A: ±(1% of Reading +1A)
50 to 400A: ±(1% of Reading +0.5A)
400 to 600A for duration <10min: ±(3% of Reading +1A)
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125mS to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode* (XRM™)
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurement (512KB)
The recorded data is stored in non-volatile memory and will be
retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Communication Rate 115200 bps
Power Source** 2x1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days
(dependent on sample rate and recording length)
*This unique recording mode provides the opportunity to continuously record over long periods
of time by reducing the stored sample resolution of the oldest data and maintaining matching
resolution for the newest data. Each time the memory lls up using XRM™, every other of the
oldest stored samples is discarded making room for newer samples. This process continues
until the recording is manually stopped.
**A memory backup capacitor provides backup power while the batteries are being changed.
This backup capacitor will maintain the instrument for up to 10 seconds without batteries
installed. After 10 seconds the date, time and conguration will need to be reset (no data will
be lost). If the unit is connected to DataView®via a PC, the battery life is 100 hours regardless
of the storage rate.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664
Indice
Altri manuali AEMC Strumento di misura

AEMC
AEMC MR521 Manuale utente

AEMC
AEMC MN352 Manuale utente

AEMC
AEMC 6550 Manuale utente

AEMC
AEMC MN353 Manuale utente

AEMC
AEMC powerpad 3945 Manuale utente

AEMC
AEMC MN307 Manuale utente

AEMC
AEMC MD305 Manuale utente

AEMC
AEMC 193-24-BK Manuale utente

AEMC
AEMC 4620 Manuale utente

AEMC
AEMC PowerPad 8436 Manuale utente