AEMC FlexProbe 24-3001 Manuale utente

FLEXIBLE
AC CURRENT PROBE
FlexProbe
®
24-3001
ENGLISH User Manual
®
INSTRUMENTS
CAT III
1000V
300A
3000A
OFF
ON OL
FlexProbe
®
24-3002
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer.
Serial #: ________________________________
Catalog #: 2120.81
Model #: 24-3001
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

2
FlexProbe®- Flexible AC Current Probe
Table of Contents
1. INTRODUCTION............................................................................... 3
1.1 International Electrical Symbols................................................3
1.2 DenitionofMeasurementCategories .....................................4
1.3 ReceivingYourShipment..........................................................4
1.4 OrderingInformation.................................................................4
1.4.1 AccessoriesandReplacementParts............................4
2. PRODUCT FEATURES ...................................................................... 5
2.1 Description................................................................................5
2.2 GeneralFeatures......................................................................6
2.3 FlexProbe®24-3001Features ..................................................7
3. SPECIFICATIONS............................................................................. 8
3.1 Electrical ...................................................................................8
3.2 Environmental...........................................................................9
3.3 MechanicalSpecications ........................................................9
3.4 SafetySpecications ..............................................................10
4. OPERATION .................................................................................. 11
4.1 MakingMeasurementswiththeFlexProbe®........................... 11
4.2 TipsforMakingPreciseMeasurements..................................12
5. MAINTENANCE ............................................................................. 14
Warning...........................................................................................14
5.1 ChangingtheBattery ..............................................................14
5.2 Cleaning..................................................................................14
Limited Warranty ...................................................................................16
WarrantyRepairs...................................................................................16
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

FlexProbe®- Flexible AC Current Probe
3
CHAPTER 1
INTRODUCTION
WARNING
• Read the instruction manual completely and follow all the safety
informationbeforeattemptingtouseorservicethisinstrument.
• Wearprotectiveclothingandglovesasrequired.
• Use caution on any circuit: potentially high voltages and currents
maybepresentandmayposeashockhazard.
• Read the safety specications section prior to using the current
probe.Neverexceedthemaximumvoltageratingsgiven.
• Safetyistheresponsibilityoftheoperator.TheFlexProbe®mustbe
used only by qualied personnel using applicable safety precau-
tions.
• ALWAYS de-energize the circuit before wrapping the FlexProbe®
aroundbareconductors,busbars,ornearliveparts.Donotwrapon
liveconductors.
• ALWAYSconnecttheelectronicmoduletothedisplaydevicebefore
wrappingtheFlexProbe®aroundthesamplebeingtested.
• ALWAYSinspectthemodule,sensor,sensorcable,andoutputtermi-
nalspriortouse.Replaceanydefectivepartsimmediately.Useonly
factoryparts.
• NEVER use the FlexProbe® on electrical conductors rated above
1000V CAT III and 600V CAT IV.
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or reinforced
insulation.
This symbol on the instrument indicates a WARNING and that the operator must
refer to the user manual for instructions before operating the instrument. In this
manual, the symbol preceding instructions indicates that if the instructions are
not followed, bodily injury, installation/sample and product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may be
dangerous.
This symbol refers to a type B current sensor. Do not apply around or remove from
HAZARDOUS LIVE conductors without additional protective means (de-energizing
the circuit or wearing protective clothing suitable for high voltage work).
In conformity with WEEE 2002/96/EC
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

4
FlexProbe®- Flexible AC Current Probe
1.2 Definition of Measurement Categories
CAT I: FormeasurementsoncircuitsnotdirectlyconnectedtotheAC
supply wall outlet such as protected secondaries, signal level,
andlimitedenergycircuits.
CAT II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
CAT III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installationandcircuitbreakers.
CAT IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyour shipment,makesure thatthecontents are consis-
tentwiththe packinglist.Notify yourdistributorof anymissingitems. If
theequipmentappearstobedamaged,leaclaimimmediatelywiththe
carrierandnotifyyourdistributoratonce,givingadetaileddescriptionof
anydamage.Savethedamagedpackingcontainertosubstantiateyour
claim.
1.4 Ordering Information
FlexProbe®24-3001 (300/3000AAC,24",10mV/A/1mV/A,withlead)
.... Cat. #2120.81
Includes a exible probe with electronic module, 9V battery and a user manual.
1.4.1 Accessories and Replacement Parts
Banana(Female)/BNC(Male)Adapter............................. Cat. # 2118.46
ForconnectionofFlexProbe®toBNCterminalsonscopesandotherdis-
playinginstruments.
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

FlexProbe®- Flexible AC Current Probe
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheFlexProbe®isaexibleACcurrenttransformercomposedofaexible
sensorandanelectronicmodule.The exiblesensorpermitsmeasure-
mentsonconductorswherestandardclamp-onprobescouldnotbeused.
In particular, it can be installed in tight spaces, around breaker panels,
aroundcablebundles,aroundwideorlargebusbars,orevenwrapped
aroundirregularshapes.
TheShapeMemoryfeatureenablestheuserto“pre-shape”thesensor
beforeinsertingitbetweenoraroundconductors.Thisfeaturefacilitates
closing,enhancesusersafety,andalleviatesthedroopingeffecttypically
associatedwithexiblesensors.
TheFlexProbe®islightweight.Itdoesnotusemagneticcoreslikestandard
transformers.Thetransformationprincipleisbasedonanaircore.Itpres-
entsvirtuallynoloadtothesystemundertest,hasalowphaseshiftand
excellentfrequencyresponse,andcannotbedamagedbyoverloads.
Thesensorassemblyiswaterproofandinsulatedfor1000VCATIII;600V
CATIV.TheFlexProbe®meetsEN61010-1andisCEmarked.
The FlexProbe® has a mV output proportional to the current measured
fordirectreadingsonDMMs,dataloggers,oscilloscopes,andpoweror
harmonicmeters.TRMSmeasurementsaretakenwhenconnectedtoa
TRMSmeter.TheFlexProbe®isinsensitivetoDCcurrentsandonlythe
ACcomponentofthemeasuredsignalismeasured.Thesensorlengthis
24".
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

6
FlexProbe®- Flexible AC Current Probe
2.2 General Features
• Modelstomeasurefrom0.5to30,000Arms
• Accuracy1%ofReading±500mA
• TRMSmeasurementswhenconnectedtoaTRMSinstrument
• Nocoresaturationordamageifoverloaded
• OverrangeLEDformeasurementcircuitry
• EN61010;1000VCATIII;600VCATIV
• Waterproofsensor
• 9Vbatteryfortypical150hourcontinuousoperations
• ShapeMemory™forcustompre-shapingofsensorbeforeuse
(nodrooping)
• Highfrequencyresponse
• Lowphaseshiftforpowermeasurements
•
InsensitivetoDC,measuresonlyACcomponentonDC+AC
signals
• Excellent linearity
• Lightweight
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

FlexProbe®- Flexible AC Current Probe
7
2.3 FlexProbe®24-3001 Features
®
INSTRUMENTS
CAT III
1000V
300A
3000A
OFF
ON OL
FlexProbe
®
24-3002
1
2
3
6
4
5
8
7
1. Flexiblesensor(Ø0.5",12.5mm)
2. Rangeselectionswitch
3. PowerONindicator(GreenLED)
4. Overload indicator (Red LED)
5. Electronicmodule
6. Doubleinsulated14"(36cm)leadwith4mmsafetybananaplugs
7. FlexProbe®connector/latch
8. Sensor lead
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664

8
FlexProbe®- Flexible AC Current Probe
CHAPTER 3
SPECIFICATIONS
Reference Conditions: 41°F ± 5°F (23°C ± 3°C), 20 to 70% RH, 50Hz, 1 minute warm-up, battery at
9V ± 0.1V, external magnetic eld < 40A/m, no DC component, no external current carrying conduc-
tor, 10MΩ load, conductor center.
3.1 Electrical
Current Range: 300/3000AAC
Output Signal:mVoutput(4000mVpeakmax)
Three position slide switch: 10mV/A 5A to 300Arms
1mV/A 50A to 3000Arms
ON/OFF
AC Current Accuracy (after calibration and for one year):
1%ofReading±500mA
Crest Factor: 4.5
Phase Shift:<0.7°at50or60Hz
Frequency Range:40to5kHz
Residual Noise When I Measured = 0: 200mArms
Working Voltage: 1000VrmsCATIII;600VCATIV
Common Mode Voltage: 600Vrms max
Inuence of Frequency: Add1%tothereferenceaccuracybetween40
and2000Hz,andupto5%at5kHz
Inuence of Adjacent Conductor: <2%
Inuence of Conductor Position in Jaw: <4%
Power Source:9Valkaline(NEDA1604A,IEC6LR61)
Battery Life: 150hourstypical(continuoususe)
300hourswithLithiumbattery
Low Battery:GreenLEDOffwhen≥7V
Overload Indication:
RedLEDindicatesinputgreaterthanselectedrange
www.ShopAEMC.com
Shop for AEMC products online at: 1.888.610.7664
Altri manuali per FlexProbe 24-3001
1
Indice
Altri manuali AEMC Apparecchiature di prova

AEMC
AEMC 6417 Manuale utente

AEMC
AEMC 4620 Manuale utente

AEMC
AEMC OX 5042 Manuale utente

AEMC
AEMC 6416 Manuale utente

AEMC
AEMC 6472 Manuale di servizio

AEMC
AEMC MF 300-6-2-10-HF Manuale utente

AEMC
AEMC 6470-b Manuale utente

AEMC
AEMC CM605 Manuale utente

AEMC
AEMC 6471 Manuale utente

AEMC
AEMC 3620 Manuale utente
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione