Afikim Afi-lite Plus Manuale utente

A
fi-lite Plus
Milk Meter
(Product number 4098999)
User Manual
¬
http
February 27, 2003
Kibbutz Afikim, 15148, ISRAEL
+972-4-675-4811
+972-4-675-1862
www.afimilk.co.il
This manual P/N 9040310
TM

Afi-lite User Manual P/N 9040310
b

February 27, 2003
Afi-lite User Manual
c
Table of Contents
Chapter 1: Overview ................................................................................. 1
Chapter 2: The Milk Meter Control Box ................................................ 3
Key functions.......................................................................................... 8
Operating the Afi-lite Milk Meter........................................................... 5
Milking with Afi-lite milk meters ....................................................... 5
Cow and Milk Information Accessible from Afi-lite........................11
Milking Codes and Messages................................................................. 9
Milking Codes...................................................................................13
Messages ........................................................................................... 16
Chapter 3: Cleaning Routine................................................................... 19
Warnings
: ...........................................................................................19
Recommendations: ............................................................................... 19
General Instructions..............................................................................20
Cleaning Cycle ..................................................................................... 20
Detergent Wash.................................................................................21
Acid Wash.........................................................................................22
Operation in Cleaning Mode ................................................................ 22
Chapter 4: Milk Meter Body and Fat Sampler ...................................... 23
The Milk Meter Body, Structure and Components ..............................24
Silicone and Rubber Component Replacement....................................26
The Fat Sampler....................................................................................27
Mounting the Fat Sampler................................................................. 27
Fat Sampler Operation ...................................................................... 27
Chapter 5: Troubleshooting .................................................................... 29
Premature cluster removal alert............................................................29
Error messages......................................................................................29
E01 Error Message............................................................................ 29
E02 Error Message............................................................................ 29
E03 Error Message............................................................................ 29
Maintenance and Troubleshooting ....................................................... 30
Index......................................................................................................... 31

Afi-lite User Manual P/N 9040310
d

February 27, 2003
Afi-lite User Manual
e
Updates
to the Afi-lite Plus user manual
Through out this manual, the term Afilite milk meter refers to the Af-lite
Plus
milk
meter.
This table is a list of updates inserted into this manual.
Page Subject of update Date of update
5 The appearance of the 7 segment display, when starting up,
has been corrected. June 17, 2003
6
(one sheet)
Stimulation activation instructions are added. July 27, 2003
9
10
(one sheet)
When assigned to an animal,
ALL
milking codes (1-8)
deactivate the key. May 20, 2003
11 Table depicting how codes are displayed is updated. May 20, 2003
15 When entering milk meter ID number,
press
and
(not 6 key). June 19, 2003
16
(one sheet)
The
Milk Flow Rate formula
has been updated. July 27, 2003
30 Error message
E05
is added to troubleshooting. June 17, 2003

Afi-lite User Manual P/N 9040310
f

February 27, 2003
Afi-lite User Manual
1
Chapter 1: Overview
The Afi-lite milk meter is installed at every milking point and performs the
following tasks during milking:
• Measures the amount of milk produced.
• Measures conductivity of the milk.
• Controls Automatic Cluster Removal (ACR).
• Displays cow information.
• Alerts milkers to health and milking irregularities.
The S.A.E. Afikim Afi-lite milk meter is made up of two units:
• The Afi-lite control box.
• The Afi flo milk meter body.

Afi-lite User Manual P/N 9040310
2

February 27, 2003
Afi-lite User Manual
3
The Afi-lite milk meter control box
Chapter 2: The Milk Meter Control Box
This chapter describes operation of the Afi-lite milk meter control box.

Afi-lite User Manual P/N 9040310
4
+
Key functions
The keys, and their functions, are described below. At the press of each key
side lights glow on the sides of the control box, to verify contact.
The Start key: Press this key to start milking.
Press the start key twice rapidly when:
The cow at the milking point is not identified.
After manually entering the cow number, press
twice rapidly to start milking.
A milking code has deactivated the start key. The cow
may need special attention if this occurs (page 9).
After the making the necessary preparations, press
twice rapidly to start milking.
The Stop key: Pressing this key manually stops milking and activates
cluster removal.
After the cluster removal process is finished, pressing this key
lowers the cluster. Pressing it again returns the cluster to the
upper position. This is helpful when adjusting cluster tubes.
This also enables you to attach the cluster to the jetter while
other cows are still being milked.
The Cancel ACR key: Afi-lite will detach the cluster
automatically, when the milk flow rate drops to a
predefined level. Manual detachment is
performed to override this mechanism. Pressing
this key cancels the automatic cluster removal.
The red LED in this key is illuminated when the
Automatic Cluster Removal is cancelled.
If the Cancel ACR is activated, the milker must
press the stop key ( ) to manually remove
the cluster,
when the cow has finished milking.
The Cleaning Mode key:
The red LED in this key is illuminated when the milk
meter is in Cleaning Mode.
Press this key to toggle between milking mode and
cleaning mode.
The Cow Identification key: Press this key to see the number of
the cow identified at the milking point.
The Conductivity key: Press this key to display the milk conductivity
of the cow at the milking point. The milk
conductivity of mastitic cows is usually higher than
normal. If a milk alert is displayed, compare the
conductivity to the expected conductivity, as
described on page 7.