5
© American Time
DSY261RSxE Owner's Manual Specications
GENERAL
Weight: ..............................Digital Clock/Timer ............................... 4.0 lb.
...............................ATSTCS Control Station ........................... 0.27 lb.
External Dimensions:.........Digital Clock/Timer ............................... 6.1"h x 12"w x 3.5"deep
ATSTCS Control Station ........................... 4.63"h X 4.56"w X 1.25"deep
SPECIFICATIONS
ELECTRICAL
Power Requirements (Digital Clock/Timer only):
Line Voltage: ..................................................................................... DSY261RSAE and DSY261RSPE -120vac 60Hz
DSY261RSBE - 24vac 60Hz
DSY261RSKE - 220vac 60Hz
DSY261RSKE50H - 220vac 50Hz
Note: Voltage is set at factory. See above part number sufx for reference.
Battery:............................................................................................... 9vdc Rechargeable Ni-Cad Battery
Battery Charger: ................................................................................ 9vdc Direct Current source with
current limiting resistor.
Maximum Current (Digital Clock/Timer only): .................................... 120vac 60Hz - 130mA (max), 101mA (avg)
24vac 60Hz -
220vac 60Hz -
220vac 50Hz -
Memory Retention on Loss of Line Voltage: ..................................... 4 hours with fully charged battery
Distance of ATSTCS from Digital Clock/Timer:................................. 30-ft maximum with 22 AWG stranded wire
............................................................................................... with minimum 1/32" thick insulation
Clock Circuits: ................................................................................... 3.0mA. max. @ 24vac/120vac
Code Blue Circuits: ............................................................................ 3.0mA. max. @ 12vac/vdc-30vac/vdc
ENVIRONMENTAL
Ambient Operating Range: ................................................................ 10°C to 49°C (50°F to 120°F)
Recommended Storage Temperature: .............................................. -30°C to 45°C (-22°F to 113°F)
............................................................................................... for six months maximum
Humidity:............................................................................................ 85 %RH at 30°C (86°F)
OPERATION
Modes Available:................12 hour or 24-hour non-system clock
12 hour secondary clock
Incrementing timer with programmable preset value and start/stop capability
Decrementing timer with programmable preset value and start/stop capability
Code Blue incrementing timer
Accuracy: .............................................................................with line voltage applied - line synchronous
with line voltage not applied - ± 0.005 % at 25°C
Indications: ........................Digital Clock/Timer .....................hours and minutes - 2.3", bright red, seven segment LED’s
hours and minutes are separated by a colon
seconds - 1", bright red, seven segment LED’s
ATSTCS Control Station ..............2 second audible alarm