ANDILOG CENTORMETER EASY Manuale utente

Operating Manual - 1.0
CENTORMETER EASY
Operating Manual
CENTORMETER EASY
V1.0
ANDILOG Technologies - BP62001 - 13845 Vitrolles Cedex 9 - France
Ph: +33(0)820.888.202 –Fax: +33(0)820.888.902

Operating manual –V1.0
CENTORMETER EASY
- 1 -
I. Introduction ...............................................................................................................................2
1. Presentation ..........................................................................................................................2
2. Definition...............................................................................................................................2
II. Handling.................................................................................................................................2
1. Unpacking..............................................................................................................................2
2. Recommendation before first use ........................................................................................3
3. Product presentation ............................................................................................................4
4. Starting your torque analyzer CENTORMETER EASY.............................................................6
5. Display mode .........................................................................................................................7
6. Reset function .......................................................................................................................8
7. Measure unit .........................................................................................................................8
8. Peak values ............................................................................................................................8
9. Backlight ................................................................................................................................8
10. Perform a measurement .......................................................................................................8
III. Advanced Features..............................................................................................................10
1. Setting screen:.....................................................................................................................10
2. Display .................................................................................................................................11
3. System setting .....................................................................................................................12
4. Using the RS232 Output ......................................................................................................12
IV. Associated products ............................................................................................................13
1. Acquisition software............................................................................................................13
2. Interface Cables...................................................................................................................13
V. APPENDICES.........................................................................................................................14
1. Keyboard chart ....................................................................................................................14
2. Actions:................................................................................................................................14
3. Error messages ....................................................................................................................15
4. SubD15 connector ...............................................................................................................15
Revision
Date
Description
Rev. 1.0
04.2015
Creation

Operating manual –V1.0
CENTORMETER EASY
- 2 -
I. Introduction
1. Presentation
Thank you for choosing the CENTORMETER EASY Torque analyzer manufactured by Andilog
Technologies.
This torque analyzer is the result of 25 years experience in force and torque measurements with
new electronic technologies offering a higher-performance and more reliable instrument.
2. Definition
To help you during the reading of this Operating Manual, please find below some definitions:
INTERNAL CHANEL: Also known and called as Channel V1 or Internal sensor. Referred to the
sensor which is connected to the board. This sensor cannot be disconnected from the unit. The
sensor may however be located inside the housing or outside therefore and connected by a wire
at the bottom of the gauge. The sensor can be measuring; force, torque linear or angular
displacement.
CALIBRATION: The CENTORMETER units are calibrated by Andilog and always delivered with a
certificate of calibration according to COFRAC standard. It is generally recommended to re-
calibrate your equipment once a year unless different internal procedure of you company
applied. Com-Ten Industries guarantee a full check up of your equipment, with software update
and also the adjustment of the calibration to ensure perfect accuracy of your force gauge.
II. Handling
CAUTION - Unpacking: Check that it has not been damaged during transportation. If you have
any doubt, please contact us, and our service support will you guide you through simple checks
to ensure that the gauge has not been damaged.
1. Unpacking
The CENTORMETER Easy is supplied with:
Power cord
Certificate of calibration
Operating manual

Operating manual –V1.0
CENTORMETER EASY
- 3 -
2. Recommendation before first use
a.Battery
The battery reaches its maximum capacity after several charges. This is very important! A new
gauge has a battery that does not have its full capacity at the first power on. The gauge will shut
down automatically if the battery is too low.
The battery life is 8 hours under a normal use. The gauge should be charged after normal use.
You should charge it every 3 weeks, to ensure a maximum life time of the batteries.
It is recommended to use the original power adaptor supplied by ANDILOG Technologies. The
power adaptor has the following specifications: 12V, 1.5A
b. Sensor
In spite of its mechanical protection, sensor overload can damage the
instrument. The instrument stops if the capacity has been exceeded 10 times.
You have to return it to ANDILOG TECHNOLOGIES for checking.
It is important that measured values are under 90% of the sensor capacity.
c.Test bench
The unit can be affixed to a test bench via the four holes on the unit’s base.
d. Conditions
Working Temperature: 0°C to +35°C
Stock Temperature: -20°C to +45°C
Humidity: 5% to 95%
Altitude: 3000m

Operating manual –V1.0
CENTORMETER EASY
- 4 -
3. Product presentation
General view:
Back of the Centormeter
Run down adapteur
(optional accessories
for motorized torque
tools))
Internal senor supply
with matching
square
4 fixing
holes
Display
Power switch
USB/RS232 Output
Power supply
(110V/220V)
Not used
Not used

Operating manual –V1.0
CENTORMETER EASY
- 5 -
Display presentation:
VALUE DISPLAY
BACK LIGHT
SETTING MODE
CANCELS ACTIONS
DISPLAY OF
PEAK VALUES OR
CALCULATIONS
UNIT CHANGE
ON/OFF BUTTON

Operating manual –V1.0
CENTORMETER EASY
- 6 -
4. Starting your torque analyzer CENTORMETER EASY
Press the I/O button, the information screen showing the status of the CENTORMETER force
gauge is displayed for 5 seconds and then the main screen is displayed.
Software version: the line indicates the software version installed on the force gauge.
Current date: displayed according to the format: DD / MM / YYYY.
Battery information:
When the battery is low, a low battery message is displayed on the screen as the gauge is
turned on, before carrying out tests.
If the charger is connected, the message « CHARG » will be displayed.
While displaying low battery indication, CENTORMETER gauge runs internal tests. If during these
tests, problems are detected, the internal information screen is displayed.
An error message indicates that the gauge is not in optimum operating condition for measuring.
Please see the Appendices chapter for the meaning of indications and error messages.
If the error detected makes measurement impossible (defective sensor for example), the display
will hold and it will be impossible to take any further action. Then return the instrument to
ANDILOG TECHNOLOGIES for examination.
If the error detected does not make measurement impossible (low battery for example) you can
switch to the main screen by pressing MAX button.
ANDILOG
CENTORM EASY
V 3.36
DATE:
01/01/2015
BAT :100%
Gauge version
Software version
Battery information

Operating manual –V1.0
CENTORMETER EASY
- 7 -
5. Display mode
NOTE: Described here are manufacturer settings, prepared by ANDILOG TECHNOLOGIES for
delivery.
When turned on, CENTORMETER force gauge displays a small square in the middle of main
screen (line 1). This small square slides from left to right and then the value of the force applied
to the force gauge sensor appears on line 1 in big letters. If no force is applied, CENTORMETER
force gauge displays « 0 ».
Sensor Capacity: the range of the sensor detected can be displayed at any time, even for
additional external sensor.
Measure unit: indicates the unit used for the display. Several units are available. Press the
“UNIT” button to change the measure unit.
Line 1: displays the current reading.
Time Bar graph: a black line is the representation of the time.
Line 2: displays the maximum, minimum, current values and calculations. Could be selected by
pressing “MAX” button.
Status line: Low battery indication: pictogram indicating the battery power status via 4
horizontal lines which respectively symbolize 25%, 50%, 75% and 100% of power. When adaptor
is connected, this pictogram flashes.
3 Nm
+0000
MXI+00.00
VLI
Measure Unit
Sensor Capacity
Line 1
Time Bar graph
Line 2
Status line

Operating manual –V1.0
CENTORMETER EASY
- 8 -
An easy-to-remember small symbol indicates the direction of the force exerted on the sensor (
).
VAL 1: indicates the value displayed on line 1. You can effectively modify the information
displayed on this line. We will see on Chapter 4 part C how to change the displayed value.
NOTE: on lines 1 and 2 you can display the following values:
VLI: current value MXI: maximum value
MNI: minimum value CP: calculation (If calculation is used)
6. Reset function
Press on “ZERO” button to reset the force gauge.
This button allows for tare. The gauge will take into consideration the weight of accessories
(hook or plate) fixed on the sensor’s rod.
Pressing this button resets all memories and peak values.
NOTE: When turned ON the CENTORMETER completes several self-tests to check the sensor’s
health. It is possible to leave tools fixed on the force gauge, but the total weight must not
exceed 20% of the sensor’s maximum capacity.
7. Measure unit
To change the unit of measure, just press “UNIT” button.
When the force gauge has an external sensor attached, it detects the type of sensor connected
and displays the corresponding units.
8. Peak values
The CENTORMETER automatically calculates peak values (maximum and minimum) and
systematically displays them on line 2. Pressing “MAX” button makes max. Value, min. value and
current value successively display (as well as a calculation if it has been set).
To reset those values press the “ZERO” button.
9. Backlight
You can turn on the backlight by pressing “O” button.
When using the force gauge on battery, the backlight automatically turns off after 3 minutes of
operation. The total battery life the CENTORMETER will be reduced when the backlight is turned
on.
When the gauge is used with the charger, the backlight does not switch off.
10. Perform a measurement

Operating manual –V1.0
CENTORMETER EASY
- 9 -
Place your torque tools to control in the square fixture of the Centormter Easy. Press the ZERO
button to reset to 0 the maximum and minimum values. Apply torque on your torque tools.
The Centometer Easy automatically display the maximum values measured on the first line and
will remember it until the ZERO buttons is pressed or the power is turned off.
To make the next test, press ZERO
You can also send the maximum value to a PC pressing the TDX button or from the optional RSIC
Lab software.